Aim: Test probes in update_endstops only when activated
Changes:
Configurations
Add define for FIX_MOUNTED_PROBE to handle the situation where formerly ENDSTOPS_ONLY_FOR_HOMING had to be set, or lowering the nozzle below Z_PROBE_OFFSET_FROM_EXTRUDER could give an "endstop hit" message.
Add define for Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to indicate a common situation, that we have a probe but it is connected to an endstop pin
Add some comments
Shift some entries to have related things together.
Conditionals.h
We have a probe (HAS_Z_MIN_PROBE) if one of the pins is defined AND one of the probes is defined.
SanityCheck.h
Add some tests if the probe is connected and if we have defined a probe.
stepper.cpp
Changes to test the probe only when it is deployed (z_probe_is_active).
Test update_endstops() when the probe is deployed.
MarlinMain.cpp
a. set and reset z_probe_is_active in deploy_z_probe(), stow_z_probe() and dock_sled()
b. set and reset z_probe_is_active in the case a z-servo is moved to a defined position. The only remaining unhandled servo move is in M280 where we do not end in a defined position. If you want to handle a probe use M401/402
c. skip deploying/stowing when already deployed/stowed in the dedicated deploy/stow functions.
d. Handle the new FIX_MOUNTED_PROBE in parallel to a servo driven probe/endstop.
To do: In another PR. handle all probes in deploy/stow_z_probe.
Sort out SERVO_LEVELING vs. HAS_SERVO_ENDSTOPS.
If Marlin is blocking the serial input or command queue for any length
of time (for example more than 2 seconds), it needs to send a message
to serial out to inform the host that it is busy. Marlin should only
send these messages out when busy, and preferably not when trying to
print formatted output.
Addressing #3085. If the target_temperature is set directly it never invokes or disables the timer set in `start_watching_heater`, so after _stopping a print_ or turning off _all heaters_ you could get a “Heating failed” error.
Expected behavior: After editing a value the menu should return to the
previous place with the edited item selected.
Actual behavior: Either the top (back) item from the previous screen is
selected, or the menu jumps up another level.
Solution: Pass the correct arguments to `lcd_goto_menu` on click when
editing a value.
rebased
corrected spelling
changed to #elif for error
Still with MIN_Z_HEIGHT_FOR_HOMING but con be done with (folder wide) search-replace when we have a better name.
- also by default use ${HOME}/Arduino as install directory which may be more
sane, especially with arduino packages provided by distributions
- bump arduino version to 106 (this seems to be useless)
- program firmware through the USB serial which is more comfortable way how
to program the firmware
- use 57600 programing speed by default which seems to be more reliable
with arduino bootloaders (at least with those shipped with the Melzi2 boards)
Signed-off-by: Jaroslav Škarvada <jskarvad@redhat.com>