AnHardt
5126cce7fd
Move Allen Key probe move scripts to their own functions
There was an hidden extra move after the scripts. This is configurable now.
Added the extra moves to the relevant configs.
8 years ago
Anthony Birkett
e77844594d
readme.md -> README.md
8 years ago
Anthony Birkett
a0b00d29e3
Add a ported example configuration for the Velleman K8400 (Vertex) printer.
Supports both dual and single head printers (with the correct config).
Includes community sourced feed rate fix.
Rename / move files.
Remove redundant definitions.
8 years ago
esenapaj
95347fc650
Follow-up the PR #3662 (Rewritten FILAMENT_CHANGE_ENABLE feature)
・Update a forgotten Configuration_adv.h of Cartesio
8 years ago
Petr Zahradnik
43ff0ce35f
Rewritten FILAMENT_CHANGE_ENABLE feature
9 years ago
Anthony Birkett
7a377c1d75
Add "About Printer" information menu.
Includes:
*firmware version / branch / date.
*extruder count
*board information (name, serial details, power supply type)
*thermistors (names, min/max temperatures)
*printer statistics (PRINTCOUNTER details)
Thanks to @thinkyhead for contributions.
8 years ago
Scott Lahteine
f84d85f761
Cleanup extruder runout configs
8 years ago
Scott Lahteine
683975cf90
Fix spelling in a config comment
8 years ago
Scott Lahteine
593c8bf286
Support for Rigidbot V2
8 years ago
Scott Lahteine
10da7ac86c
Combine Z raise before/after options
8 years ago
Scott Lahteine
03c70c1990
SERVO_DEACTIVATION_DELAY => SERVO_DELAY
8 years ago
Scott Lahteine
bd01592816
Goodbye MECHANICAL_PROBE
8 years ago
Scott Lahteine
b590a7dee0
Make Z_RAISE_BETWEEN_PROBINGS a more general option
8 years ago
Scott Lahteine
d50539583a
Make XY_PROBE_SPEED a general probe option
8 years ago
Scott Lahteine
2798499b71
XY_TRAVEL_SPEED => XY_PROBE_SPEED
8 years ago
João Brázio
19fb04d761
Update bq Hephestos 2 config
8 years ago
Scott Lahteine
40cd20a236
Fix comments on EXPERIMENTAL_I2CBUS
8 years ago
esenapaj
d583ea852d
Standardize format description of Panel
8 years ago
esenapaj
aa6d35bd49
Move code block of probe to appropriate position
8 years ago
esenapaj
740fb2ce39
Adjust spacing
8 years ago
esenapaj
f77f3ffa70
Remove duplicated Z_PROBE_OFFSET_RANGE_MIN, Z_PROBE_OFFSET_RANGE_MAX
8 years ago
Scott Lahteine
19fe93a5a9
Clean up configs for Z_MIN_PROBE_REPEATABILITY_TEST
8 years ago
Scott Lahteine
3996242e9d
Allow Z_MIN_PROBE_REPEATABILITY_TEST solo
8 years ago
Scott Lahteine
dfbf8b3c2c
FIL_RUNOUT_INVERTING false by default
9 years ago
Scott Lahteine
de12228758
Make Z Probe options independent of ABL
9 years ago
Scott Lahteine
f8c278ce4d
Cartesio UI display option in all configs
9 years ago
esenapaj
d55b94d606
Follow-up the PR #4065 (Remove support for XY servo endstops)
・Update a forgotten Configuration.h of Cartesio
9 years ago
Scott Lahteine
eab44b30d4
Safety and serial sections
9 years ago
Scott Lahteine
fc56a547d1
Rename movement section to motion
9 years ago
Scott Lahteine
1000563d80
Make M851 standard with a bed probe
9 years ago
Scott Lahteine
47ce810f52
Remove support for XY servo endstops
9 years ago
esenapaj
c5eecb11b2
Follow-up the PR #4055 (Croatian language support)
・Update a forgotten Configuration.h of Cartesio
9 years ago
Scott Lahteine
ebbed2975e
Delete mysterious .swp files from #3609
9 years ago
Scott Lahteine
02e5dad29a
Include Croatian in language listings
9 years ago
esenapaj
106227540e
Follow-up and improvement the PR #4053 (CNControls Cartesio UI Support)
・Add implimantation of PR #3609 to configuration files of Cartesio
・Standardize macro names
9 years ago
Scott Lahteine
4d2cb70152
Cartesio UI Support
9 years ago
esenapaj
741cda0e47
Follow-up the PR #3676(Advance extrusion algorithm – LIN_ADVANCE)
・Update forgotten example configurations
9 years ago
João Brázio
8ccd97e7cc
Updated all example configuration files
9 years ago
Reid Rankin
16212432c9
G20/21 and M149 support, and code_value() refactor
This is an update of MarlinDev PR #196 .
G20/21: support for switching input units between millimeters and
inches.
M149: support for changing input temperature units.
In support of these changes, code_value() and code_value_short() are
replaced with an array of functions which handle converting to the
proper types and/or units.
9 years ago
Scott Lahteine
cd441ce652
SINGLENOZZLE: EXTRUDERS versus HOTENDS
9 years ago
Scott Lahteine
db0fd021d0
Z raise options independent of ABL so G28 can use them
9 years ago
Scott Lahteine
28fb1f8994
Tweak #endif comment for ABL GRID
9 years ago
Scott Lahteine
a0b000d752
Support for SAV_3DGLCD OLED LCD controller
9 years ago
Scott Lahteine
43a71ef226
Remove excess allen key probe examples from configs
9 years ago
Edward Patel
06593833ff
MBL: Move border macros to Configuration_adv.h
9 years ago
Edward Patel
92a27c37b3
MBL: Apply https://github.com/MarlinFirmware/Marlin/pull/3903 to example_configurations
9 years ago
Scott Lahteine
95fee8ca81
Add option for CoreYZ kinematics
9 years ago
Scott Lahteine
c5130fd23b
Additional instructions for controller reverse options
9 years ago
Scott Lahteine
69abfef82e
Add "SINGLENOZZLE" extruder option
9 years ago
Scott Lahteine
1a6c72cb57
Apply to the rest of the configs
9 years ago