Probing with the effector in the printing area, but an eccentric probe (e.g. allen key) outside it but still touching the bed gives meaninfull information for calibration. Since calibration is most accurate when probing as close to the towers as possible the testing was way to restrictive hence this fix.
==============================
Configuration_adv.h changes
==============================
add "live" LCD update
==============================
P & S version
==============================
final (hopefully) tested version
==============================
update M115 capabilities print
==============================
Menu changes portion of the requested changes
==============================
changed USEABLE_HARDWARE_PWM from a function to a series of macros
==============================
changes per review
The menu (commands / scripts) is configurable in `Configuration_adv.h`.
- Added conditionals.
- Changed script handling.
- Slimmed and working!
- Added Status message.
- Returning to lcd status screen now!
- Example Configs Updated.
- Cleanups by @thinkyhead
* Unify M600 and M125 pause features
* Cleanup per thinkyhead's comments
* Rename filament_change_menu_response to advanced_pause_menu_response
* Include HAS_BED_PROBE in QUIET_PROBING
* Update gMax example file
* is_idle() is out of scope without the braces
* Convert FT-i3-2020 to Advance Pause names...
* Allow pause even if not printing
- fix broken `M421` due to less-than-careful optimization
- add HOME_AFTER_DEACTIVATE define to advanced config so not everyone has to rehome after steppers are deactivated
- misc. cleanups (remove unused label, unused variables)
- rename to PROBING_HEATERS_OFF
- move heater pausing functionality into thermalManager
- add variables, pause(), ispaused(), other functions
- add fan pausing functionality -> PROBING_FANS_OFF
- add probing_pause() wrapper
- move pausing into do_homing_move() and do_probe_move() to minimize quiet time and so other probe types can benefit
- example configs
This is what I did yesterday:
- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)
- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets
- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)
-Wrote 3 dummies to keep EEPROM lenght the same
-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
The Configuration.h file entries for BL-Touch have been updated to:
```cpp
//#define BLTOUCH
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
//#define BLTOUCH_HEATERS_OFF // if defined the printer's heaters are
turned off during probe event
```