@ -224,13 +224,15 @@ void GcodeSuite::G34() { |
|
|
|
// Safe clearance even on an incline
|
|
|
|
if ((iteration == 0 || i > 0) && z_probe > current_position.z) do_blocking_move_to_z(z_probe); |
|
|
|
|
|
|
|
xy_pos_t &ppos = z_stepper_align.xy[iprobe]; |
|
|
|
|
|
|
|
if (DEBUGGING(LEVELING)) |
|
|
|
DEBUG_ECHOLNPGM_P(PSTR("Probing X"), z_stepper_align.xy[iprobe].x, SP_Y_STR, z_stepper_align.xy[iprobe].y); |
|
|
|
DEBUG_ECHOLNPGM_P(PSTR("Probing X"), ppos.x, SP_Y_STR, ppos.y); |
|
|
|
|
|
|
|
// Probe a Z height for each stepper.
|
|
|
|
// Probing sanity check is disabled, as it would trigger even in normal cases because
|
|
|
|
// current_position.z has been manually altered in the "dirty trick" above.
|
|
|
|
const float z_probed_height = probe.probe_at_point(z_stepper_align.xy[iprobe], raise_after, 0, true, false); |
|
|
|
const float z_probed_height = probe.probe_at_point(DIFF_TERN(HAS_HOME_OFFSET, ppos, xy_pos_t(home_offset)), raise_after, 0, true, false); |
|
|
|
if (isnan(z_probed_height)) { |
|
|
|
SERIAL_ECHOLNPGM("Probing failed"); |
|
|
|
LCD_MESSAGE(MSG_LCD_PROBING_FAILED); |
|
|
|