@ -187,8 +187,8 @@ |
|
|
|
|
|
|
|
Temperature thermalManager; |
|
|
|
|
|
|
|
const char str_t_thermal_runaway[] PROGMEM = STR_T_THERMAL_RUNAWAY, |
|
|
|
str_t_heating_failed[] PROGMEM = STR_T_HEATING_FAILED; |
|
|
|
PGMSTR(str_t_thermal_runaway, STR_T_THERMAL_RUNAWAY); |
|
|
|
PGMSTR(str_t_heating_failed, STR_T_HEATING_FAILED); |
|
|
|
|
|
|
|
/**
|
|
|
|
* Macros to include the heater id in temp errors. The compiler's dead-code |
|
|
@ -196,22 +196,22 @@ const char str_t_thermal_runaway[] PROGMEM = STR_T_THERMAL_RUNAWAY, |
|
|
|
*/ |
|
|
|
|
|
|
|
#if HAS_HEATED_BED |
|
|
|
#define _BED_PSTR(h) (h) == H_BED ? GET_TEXT(MSG_BED) : |
|
|
|
#define _BED_FSTR(h) (h) == H_BED ? GET_TEXT_F(MSG_BED) : |
|
|
|
#else |
|
|
|
#define _BED_PSTR(h) |
|
|
|
#define _BED_FSTR(h) |
|
|
|
#endif |
|
|
|
#if HAS_HEATED_CHAMBER |
|
|
|
#define _CHAMBER_PSTR(h) (h) == H_CHAMBER ? GET_TEXT(MSG_CHAMBER) : |
|
|
|
#define _CHAMBER_FSTR(h) (h) == H_CHAMBER ? GET_TEXT_F(MSG_CHAMBER) : |
|
|
|
#else |
|
|
|
#define _CHAMBER_PSTR(h) |
|
|
|
#define _CHAMBER_FSTR(h) |
|
|
|
#endif |
|
|
|
#if HAS_COOLER |
|
|
|
#define _COOLER_PSTR(h) (h) == H_COOLER ? GET_TEXT(MSG_COOLER) : |
|
|
|
#define _COOLER_FSTR(h) (h) == H_COOLER ? GET_TEXT_F(MSG_COOLER) : |
|
|
|
#else |
|
|
|
#define _COOLER_PSTR(h) |
|
|
|
#define _COOLER_FSTR(h) |
|
|
|
#endif |
|
|
|
#define _E_PSTR(h,N) ((HOTENDS) > N && (h) == N) ? PSTR(LCD_STR_E##N) : |
|
|
|
#define HEATER_PSTR(h) _BED_PSTR(h) _CHAMBER_PSTR(h) _COOLER_PSTR(h) _E_PSTR(h,1) _E_PSTR(h,2) _E_PSTR(h,3) _E_PSTR(h,4) _E_PSTR(h,5) PSTR(LCD_STR_E0) |
|
|
|
#define _E_FSTR(h,N) ((HOTENDS) > N && (h) == N) ? F(LCD_STR_E##N) : |
|
|
|
#define HEATER_FSTR(h) _BED_FSTR(h) _CHAMBER_FSTR(h) _COOLER_FSTR(h) _E_FSTR(h,1) _E_FSTR(h,2) _E_FSTR(h,3) _E_FSTR(h,4) _E_FSTR(h,5) F(LCD_STR_E0) |
|
|
|
|
|
|
|
//
|
|
|
|
// Initialize MAX TC objects/SPI
|
|
|
@ -731,10 +731,10 @@ volatile bool Temperature::raw_temps_ready = false; |
|
|
|
if (current_temp > watch_temp_target) heated = true; // - Flag if target temperature reached
|
|
|
|
} |
|
|
|
else if (ELAPSED(ms, temp_change_ms)) // Watch timer expired
|
|
|
|
_temp_error(heater_id, str_t_heating_failed, GET_TEXT(MSG_HEATING_FAILED_LCD)); |
|
|
|
_temp_error(heater_id, FPSTR(str_t_heating_failed), GET_TEXT_F(MSG_HEATING_FAILED_LCD)); |
|
|
|
} |
|
|
|
else if (current_temp < target - (MAX_OVERSHOOT_PID_AUTOTUNE)) // Heated, then temperature fell too far?
|
|
|
|
_temp_error(heater_id, str_t_thermal_runaway, GET_TEXT(MSG_THERMAL_RUNAWAY)); |
|
|
|
_temp_error(heater_id, FPSTR(str_t_thermal_runaway), GET_TEXT_F(MSG_THERMAL_RUNAWAY)); |
|
|
|
} |
|
|
|
#endif |
|
|
|
} // every 2 seconds
|
|
|
@ -951,7 +951,7 @@ int16_t Temperature::getHeaterPower(const heater_id_t heater_id) { |
|
|
|
// Temperature Error Handlers
|
|
|
|
//
|
|
|
|
|
|
|
|
inline void loud_kill(PGM_P const lcd_msg, const heater_id_t heater_id) { |
|
|
|
inline void loud_kill(FSTR_P const lcd_msg, const heater_id_t heater_id) { |
|
|
|
marlin_state = MF_KILLED; |
|
|
|
thermalManager.disable_all_heaters(); |
|
|
|
#if USE_BEEPER |
|
|
@ -967,16 +967,16 @@ inline void loud_kill(PGM_P const lcd_msg, const heater_id_t heater_id) { |
|
|
|
} |
|
|
|
WRITE(BEEPER_PIN, HIGH); |
|
|
|
#endif |
|
|
|
kill(lcd_msg, HEATER_PSTR(heater_id)); |
|
|
|
kill(lcd_msg, HEATER_FSTR(heater_id)); |
|
|
|
} |
|
|
|
|
|
|
|
void Temperature::_temp_error(const heater_id_t heater_id, PGM_P const serial_msg, PGM_P const lcd_msg) { |
|
|
|
void Temperature::_temp_error(const heater_id_t heater_id, FSTR_P const serial_msg, FSTR_P const lcd_msg) { |
|
|
|
|
|
|
|
static uint8_t killed = 0; |
|
|
|
|
|
|
|
if (IsRunning() && TERN1(BOGUS_TEMPERATURE_GRACE_PERIOD, killed == 2)) { |
|
|
|
SERIAL_ERROR_START(); |
|
|
|
SERIAL_ECHOPGM_P(serial_msg); |
|
|
|
SERIAL_ECHOF(serial_msg); |
|
|
|
SERIAL_ECHOPGM(STR_STOPPED_HEATER); |
|
|
|
|
|
|
|
heater_id_t real_heater_id = heater_id; |
|
|
@ -1031,14 +1031,14 @@ void Temperature::max_temp_error(const heater_id_t heater_id) { |
|
|
|
#if HAS_DWIN_E3V2_BASIC && (HAS_HOTEND || HAS_HEATED_BED) |
|
|
|
DWIN_Popup_Temperature(1); |
|
|
|
#endif |
|
|
|
_temp_error(heater_id, PSTR(STR_T_MAXTEMP), GET_TEXT(MSG_ERR_MAXTEMP)); |
|
|
|
_temp_error(heater_id, F(STR_T_MAXTEMP), GET_TEXT_F(MSG_ERR_MAXTEMP)); |
|
|
|
} |
|
|
|
|
|
|
|
void Temperature::min_temp_error(const heater_id_t heater_id) { |
|
|
|
#if HAS_DWIN_E3V2_BASIC && (HAS_HOTEND || HAS_HEATED_BED) |
|
|
|
DWIN_Popup_Temperature(0); |
|
|
|
#endif |
|
|
|
_temp_error(heater_id, PSTR(STR_T_MINTEMP), GET_TEXT(MSG_ERR_MINTEMP)); |
|
|
|
_temp_error(heater_id, F(STR_T_MINTEMP), GET_TEXT_F(MSG_ERR_MINTEMP)); |
|
|
|
} |
|
|
|
|
|
|
|
#if ANY(PID_DEBUG, PID_BED_DEBUG, PID_CHAMBER_DEBUG) |
|
|
@ -1294,7 +1294,7 @@ void Temperature::manage_heater() { |
|
|
|
REMEMBER(mh, no_reentry, true); |
|
|
|
|
|
|
|
#if ENABLED(EMERGENCY_PARSER) |
|
|
|
if (emergency_parser.killed_by_M112) kill(M112_KILL_STR, nullptr, true); |
|
|
|
if (emergency_parser.killed_by_M112) kill(FPSTR(M112_KILL_STR), nullptr, true); |
|
|
|
|
|
|
|
if (emergency_parser.quickstop_by_M410) { |
|
|
|
emergency_parser.quickstop_by_M410 = false; // quickstop_stepper may call idle so clear this now!
|
|
|
@ -1344,7 +1344,7 @@ void Temperature::manage_heater() { |
|
|
|
start_watching_hotend(e); // If temp reached, turn off elapsed check
|
|
|
|
else { |
|
|
|
TERN_(HAS_DWIN_E3V2_BASIC, DWIN_Popup_Temperature(0)); |
|
|
|
_temp_error((heater_id_t)e, str_t_heating_failed, GET_TEXT(MSG_HEATING_FAILED_LCD)); |
|
|
|
_temp_error((heater_id_t)e, FPSTR(str_t_heating_failed), GET_TEXT_F(MSG_HEATING_FAILED_LCD)); |
|
|
|
} |
|
|
|
} |
|
|
|
#endif |
|
|
@ -1356,7 +1356,7 @@ void Temperature::manage_heater() { |
|
|
|
#if HAS_TEMP_REDUNDANT |
|
|
|
// Make sure measured temperatures are close together
|
|
|
|
if (ABS(degRedundantTarget() - degRedundant()) > TEMP_SENSOR_REDUNDANT_MAX_DIFF) |
|
|
|
_temp_error((heater_id_t)HEATER_ID(TEMP_SENSOR_REDUNDANT_TARGET), PSTR(STR_REDUNDANCY), GET_TEXT(MSG_ERR_REDUNDANT_TEMP)); |
|
|
|
_temp_error((heater_id_t)HEATER_ID(TEMP_SENSOR_REDUNDANT_TARGET), F(STR_REDUNDANCY), GET_TEXT_F(MSG_ERR_REDUNDANT_TEMP)); |
|
|
|
#endif |
|
|
|
|
|
|
|
#if HAS_AUTO_FAN |
|
|
@ -1387,7 +1387,7 @@ void Temperature::manage_heater() { |
|
|
|
start_watching_bed(); // If temp reached, turn off elapsed check
|
|
|
|
else { |
|
|
|
TERN_(HAS_DWIN_E3V2_BASIC, DWIN_Popup_Temperature(0)); |
|
|
|
_temp_error(H_BED, str_t_heating_failed, GET_TEXT(MSG_HEATING_FAILED_LCD)); |
|
|
|
_temp_error(H_BED, FPSTR(str_t_heating_failed), GET_TEXT_F(MSG_HEATING_FAILED_LCD)); |
|
|
|
} |
|
|
|
} |
|
|
|
#endif // WATCH_BED
|
|
|
@ -1467,7 +1467,7 @@ void Temperature::manage_heater() { |
|
|
|
if (watch_chamber.check(degChamber())) // Increased enough? Error below.
|
|
|
|
start_watching_chamber(); // If temp reached, turn off elapsed check.
|
|
|
|
else |
|
|
|
_temp_error(H_CHAMBER, str_t_heating_failed, GET_TEXT(MSG_HEATING_FAILED_LCD)); |
|
|
|
_temp_error(H_CHAMBER, FPSTR(str_t_heating_failed), GET_TEXT_F(MSG_HEATING_FAILED_LCD)); |
|
|
|
} |
|
|
|
#endif |
|
|
|
|
|
|
@ -1589,7 +1589,7 @@ void Temperature::manage_heater() { |
|
|
|
// Make sure temperature is decreasing
|
|
|
|
if (watch_cooler.elapsed(ms)) { // Time to check the cooler?
|
|
|
|
if (degCooler() > watch_cooler.target) // Failed to decrease enough?
|
|
|
|
_temp_error(H_COOLER, GET_TEXT(MSG_COOLING_FAILED), GET_TEXT(MSG_COOLING_FAILED)); |
|
|
|
_temp_error(H_COOLER, GET_TEXT_F(MSG_COOLING_FAILED), GET_TEXT_F(MSG_COOLING_FAILED)); |
|
|
|
else |
|
|
|
start_watching_cooler(); // Start again if the target is still far off
|
|
|
|
} |
|
|
@ -2597,7 +2597,7 @@ void Temperature::init() { |
|
|
|
|
|
|
|
case TRRunaway: |
|
|
|
TERN_(HAS_DWIN_E3V2_BASIC, DWIN_Popup_Temperature(0)); |
|
|
|
_temp_error(heater_id, str_t_thermal_runaway, GET_TEXT(MSG_THERMAL_RUNAWAY)); |
|
|
|
_temp_error(heater_id, FPSTR(str_t_thermal_runaway), GET_TEXT_F(MSG_THERMAL_RUNAWAY)); |
|
|
|
} |
|
|
|
} |
|
|
|
|
|
|
@ -3896,7 +3896,7 @@ void Temperature::isr() { |
|
|
|
const bool wants_to_cool = isProbeAboveTemp(target_temp), |
|
|
|
will_wait = !(wants_to_cool && no_wait_for_cooling); |
|
|
|
if (will_wait) |
|
|
|
SERIAL_ECHOLNPGM("Waiting for probe to ", (wants_to_cool ? PSTR("cool down") : PSTR("heat up")), " to ", target_temp, " degrees."); |
|
|
|
SERIAL_ECHOLNPGM("Waiting for probe to ", wants_to_cool ? F("cool down") : F("heat up"), " to ", target_temp, " degrees."); |
|
|
|
|
|
|
|
#if DISABLED(BUSY_WHILE_HEATING) && ENABLED(HOST_KEEPALIVE_FEATURE) |
|
|
|
KEEPALIVE_STATE(NOT_BUSY); |
|
|
|