@ -683,9 +683,8 @@ void Temperature::manage_heater() { |
|
|
|
updateTemperaturesFromRawValues(); // also resets the watchdog
|
|
|
|
|
|
|
|
#if ENABLED(HEATER_0_USES_MAX6675) |
|
|
|
float ct = current_temperature[0]; |
|
|
|
if (ct > min(HEATER_0_MAXTEMP, 1023)) max_temp_error(0); |
|
|
|
if (ct < max(HEATER_0_MINTEMP, 0.01)) min_temp_error(0); |
|
|
|
if (current_temperature[0] > min(HEATER_0_MAXTEMP, 1023)) max_temp_error(0); |
|
|
|
if (current_temperature[0] < max(HEATER_0_MINTEMP, 0.01)) min_temp_error(0); |
|
|
|
#endif |
|
|
|
|
|
|
|
#if (ENABLED(THERMAL_PROTECTION_HOTENDS) && WATCH_TEMP_PERIOD > 0) || (ENABLED(THERMAL_PROTECTION_BED) && WATCH_BED_TEMP_PERIOD > 0) || DISABLED(PIDTEMPBED) || HAS_AUTO_FAN |
|
|
|