Browse Source

Move BLTouch options to adv config (#14131)

Plus other BLTouch and menu enhancements.
pull/1/head
InsanityAutomation 6 years ago
committed by Scott Lahteine
parent
commit
b7eeb5b13b
  1. 66
      Marlin/Configuration.h
  2. 67
      Marlin/Configuration_adv.h
  3. 3
      Marlin/src/lcd/language/language_en.h
  4. 16
      Marlin/src/lcd/menu/menu_configuration.cpp
  5. 35
      Marlin/src/lcd/ultralcd.cpp
  6. 6
      Marlin/src/lcd/ultralcd.h
  7. 66
      config/default/Configuration.h
  8. 67
      config/default/Configuration_adv.h
  9. 66
      config/examples/3DFabXYZ/Migbot/Configuration.h
  10. 67
      config/examples/3DFabXYZ/Migbot/Configuration_adv.h
  11. 66
      config/examples/AlephObjects/TAZ4/Configuration.h
  12. 67
      config/examples/AlephObjects/TAZ4/Configuration_adv.h
  13. 66
      config/examples/AliExpress/CL-260/Configuration.h
  14. 66
      config/examples/AliExpress/UM2pExt/Configuration.h
  15. 67
      config/examples/AliExpress/UM2pExt/Configuration_adv.h
  16. 66
      config/examples/Anet/A2/Configuration.h
  17. 67
      config/examples/Anet/A2/Configuration_adv.h
  18. 66
      config/examples/Anet/A2plus/Configuration.h
  19. 67
      config/examples/Anet/A2plus/Configuration_adv.h
  20. 66
      config/examples/Anet/A6/Configuration.h
  21. 67
      config/examples/Anet/A6/Configuration_adv.h
  22. 66
      config/examples/Anet/A8/Configuration.h
  23. 67
      config/examples/Anet/A8/Configuration_adv.h
  24. 66
      config/examples/Anet/A8plus/Configuration.h
  25. 67
      config/examples/Anet/A8plus/Configuration_adv.h
  26. 66
      config/examples/Anet/E16/Configuration.h
  27. 67
      config/examples/Anet/E16/Configuration_adv.h
  28. 66
      config/examples/AnyCubic/i3/Configuration.h
  29. 67
      config/examples/AnyCubic/i3/Configuration_adv.h
  30. 66
      config/examples/ArmEd/Configuration.h
  31. 67
      config/examples/ArmEd/Configuration_adv.h
  32. 66
      config/examples/Azteeg/X5GT/Configuration.h
  33. 66
      config/examples/BIBO/TouchX/cyclops/Configuration.h
  34. 67
      config/examples/BIBO/TouchX/cyclops/Configuration_adv.h
  35. 66
      config/examples/BIBO/TouchX/default/Configuration.h
  36. 67
      config/examples/BIBO/TouchX/default/Configuration_adv.h
  37. 66
      config/examples/BQ/Hephestos/Configuration.h
  38. 67
      config/examples/BQ/Hephestos/Configuration_adv.h
  39. 66
      config/examples/BQ/Hephestos_2/Configuration.h
  40. 67
      config/examples/BQ/Hephestos_2/Configuration_adv.h
  41. 66
      config/examples/BQ/WITBOX/Configuration.h
  42. 67
      config/examples/BQ/WITBOX/Configuration_adv.h
  43. 66
      config/examples/Cartesio/Configuration.h
  44. 67
      config/examples/Cartesio/Configuration_adv.h
  45. 66
      config/examples/Creality/CR-10/Configuration.h
  46. 67
      config/examples/Creality/CR-10/Configuration_adv.h
  47. 66
      config/examples/Creality/CR-10S/Configuration.h
  48. 67
      config/examples/Creality/CR-10S/Configuration_adv.h
  49. 66
      config/examples/Creality/CR-10_5S/Configuration.h
  50. 67
      config/examples/Creality/CR-10_5S/Configuration_adv.h
  51. 66
      config/examples/Creality/CR-10mini/Configuration.h
  52. 67
      config/examples/Creality/CR-10mini/Configuration_adv.h
  53. 66
      config/examples/Creality/CR-8/Configuration.h
  54. 67
      config/examples/Creality/CR-8/Configuration_adv.h
  55. 66
      config/examples/Creality/Ender-2/Configuration.h
  56. 67
      config/examples/Creality/Ender-2/Configuration_adv.h
  57. 66
      config/examples/Creality/Ender-3/Configuration.h
  58. 67
      config/examples/Creality/Ender-3/Configuration_adv.h
  59. 66
      config/examples/Creality/Ender-4/Configuration.h
  60. 67
      config/examples/Creality/Ender-4/Configuration_adv.h
  61. 67
      config/examples/Dagoma/Disco Ultimate/Configuration_adv.h
  62. 66
      config/examples/Einstart-S/Configuration.h
  63. 67
      config/examples/Einstart-S/Configuration_adv.h
  64. 66
      config/examples/Felix/Configuration.h
  65. 67
      config/examples/Felix/Configuration_adv.h
  66. 66
      config/examples/Felix/DUAL/Configuration.h
  67. 66
      config/examples/FlashForge/CreatorPro/Configuration.h
  68. 67
      config/examples/FlashForge/CreatorPro/Configuration_adv.h
  69. 66
      config/examples/FolgerTech/i3-2020/Configuration.h
  70. 67
      config/examples/FolgerTech/i3-2020/Configuration_adv.h
  71. 66
      config/examples/Formbot/Raptor/Configuration.h
  72. 67
      config/examples/Formbot/Raptor/Configuration_adv.h
  73. 67
      config/examples/Formbot/T_Rex_2+/Configuration.h
  74. 67
      config/examples/Formbot/T_Rex_2+/Configuration_adv.h
  75. 66
      config/examples/Formbot/T_Rex_3/Configuration.h
  76. 67
      config/examples/Formbot/T_Rex_3/Configuration_adv.h
  77. 66
      config/examples/Geeetech/A10M/Configuration.h
  78. 67
      config/examples/Geeetech/A10M/Configuration_adv.h
  79. 66
      config/examples/Geeetech/A20M/Configuration.h
  80. 67
      config/examples/Geeetech/A20M/Configuration_adv.h
  81. 66
      config/examples/Geeetech/GT2560/Configuration.h
  82. 3
      config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h
  83. 66
      config/examples/Geeetech/MeCreator2/Configuration.h
  84. 67
      config/examples/Geeetech/MeCreator2/Configuration_adv.h
  85. 66
      config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h
  86. 66
      config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h
  87. 66
      config/examples/Geeetech/Prusa i3 Pro C/Configuration.h
  88. 67
      config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h
  89. 66
      config/examples/Geeetech/Prusa i3 Pro W/Configuration.h
  90. 67
      config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h
  91. 66
      config/examples/Infitary/i3-M508/Configuration.h
  92. 67
      config/examples/Infitary/i3-M508/Configuration_adv.h
  93. 66
      config/examples/JGAurora/A5/Configuration.h
  94. 67
      config/examples/JGAurora/A5/Configuration_adv.h
  95. 66
      config/examples/MakerParts/Configuration.h
  96. 67
      config/examples/MakerParts/Configuration_adv.h
  97. 66
      config/examples/Malyan/M150/Configuration.h
  98. 67
      config/examples/Malyan/M150/Configuration_adv.h
  99. 66
      config/examples/Malyan/M200/Configuration.h
  100. 67
      config/examples/Malyan/M200/Configuration_adv.h

66
Marlin/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
Marlin/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

3
Marlin/src/lcd/language/language_en.h

@ -933,6 +933,9 @@
#ifndef MSG_BLTOUCH_MODE_ECHO #ifndef MSG_BLTOUCH_MODE_ECHO
#define MSG_BLTOUCH_MODE_ECHO _UxGT("Report Drain") #define MSG_BLTOUCH_MODE_ECHO _UxGT("Report Drain")
#endif #endif
#ifndef MSG_BLTOUCH_MODE_CHANGE
#define MSG_BLTOUCH_MODE_CHANGE _UxGT("DANGER: Bad settings can cause damage! Proceed anyway?")
#endif
#ifndef MSG_MANUAL_DEPLOY #ifndef MSG_MANUAL_DEPLOY
#define MSG_MANUAL_DEPLOY _UxGT("Deploy Z-Probe") #define MSG_MANUAL_DEPLOY _UxGT("Deploy Z-Probe")
#endif #endif

16
Marlin/src/lcd/menu/menu_configuration.cpp

@ -199,11 +199,19 @@ static void lcd_factory_settings() {
MENU_ITEM(function, MSG_BLTOUCH_STOW, bltouch._stow); MENU_ITEM(function, MSG_BLTOUCH_STOW, bltouch._stow);
MENU_ITEM(function, MSG_BLTOUCH_SW_MODE, bltouch._set_SW_mode); MENU_ITEM(function, MSG_BLTOUCH_SW_MODE, bltouch._set_SW_mode);
#if ENABLED(BLTOUCH_LCD_VOLTAGE_MENU) #if ENABLED(BLTOUCH_LCD_VOLTAGE_MENU)
MENU_ITEM(function, MSG_BLTOUCH_5V_MODE, bltouch._set_5V_mode); MENU_ITEM(submenu, MSG_BLTOUCH_5V_MODE, []{
MENU_ITEM(function, MSG_BLTOUCH_OD_MODE, bltouch._set_OD_mode); do_select_screen(PSTR(MSG_BLTOUCH_5V_MODE), PSTR(MSG_BUTTON_CANCEL), bltouch._set_5V_mode, ui.goto_previous_screen, PSTR(MSG_BLTOUCH_MODE_CHANGE));
});
MENU_ITEM(submenu, MSG_BLTOUCH_OD_MODE, []{
do_select_screen(PSTR(MSG_BLTOUCH_OD_MODE), PSTR(MSG_BUTTON_CANCEL), bltouch._set_OD_mode, ui.goto_previous_screen, PSTR(MSG_BLTOUCH_MODE_CHANGE));
});
MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE, bltouch._mode_store); MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE, bltouch._mode_store);
MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE_5V, bltouch.mode_conv_5V); MENU_ITEM(submenu, MSG_BLTOUCH_MODE_STORE_5V, []{
MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE_OD, bltouch.mode_conv_OD); do_select_screen(PSTR(MSG_BLTOUCH_MODE_STORE_5V), PSTR(MSG_BUTTON_CANCEL), bltouch.mode_conv_5V, ui.goto_previous_screen, PSTR(MSG_BLTOUCH_MODE_CHANGE));
});
MENU_ITEM(submenu, MSG_BLTOUCH_MODE_STORE_OD, []{
do_select_screen(PSTR(MSG_BLTOUCH_MODE_STORE_OD), PSTR(MSG_BUTTON_CANCEL), bltouch.mode_conv_OD, ui.goto_previous_screen, PSTR(MSG_BLTOUCH_MODE_CHANGE));
});
MENU_ITEM(function, MSG_BLTOUCH_MODE_ECHO, bltouch_report); MENU_ITEM(function, MSG_BLTOUCH_MODE_ECHO, bltouch_report);
#endif #endif
END_MENU(); END_MENU();

35
Marlin/src/lcd/ultralcd.cpp

@ -196,10 +196,39 @@ millis_t next_button_update_ms;
#endif #endif
void _wrap_string(uint8_t &x, uint8_t &y, const char * const string, read_byte_cb_t cb_read_byte) { void _wrap_string(uint8_t &x, uint8_t &y, const char * const string, read_byte_cb_t cb_read_byte, bool wordwrap/*=false*/) {
SETCURSOR(x, y); SETCURSOR(x, y);
if (string) { if (!string) return;
uint8_t *p = (uint8_t*)string; uint8_t *p = (uint8_t*)string;
if (wordwrap) {
uint8_t *wrd = p, c = 0;
for (;;) {
wchar_t ch;
p = get_utf8_value_cb(p, cb_read_byte, &ch);
const bool eol = !ch;
if (eol || ch == ' ' || ch == '-' || ch == '+' || ch == '.') {
if (!c && ch == ' ') continue; // collapse extra spaces
if (x + c > LCD_WIDTH && c < (LCD_WIDTH) * 3 / 4) { // should it wrap?
x = 0; y++; // move x to string len (plus space)
SETCURSOR(0, y); // simulate carriage return
}
c += !eol; // +1 so the space will be printed
x += c; // advance x to new position
while (c--) { // character countdown
wrd = get_utf8_value_cb(wrd, cb_read_byte, &ch); // get characters again
lcd_put_wchar(ch); // word (plus space) to the LCD
}
if (eol) break; // all done
wrd = nullptr; // set up for next word
}
else {
if (!wrd) wrd = p; // starting a new word?
c++; // count word characters
}
}
}
else {
for (;;) { for (;;) {
wchar_t ch; wchar_t ch;
p = get_utf8_value_cb(p, cb_read_byte, &ch); p = get_utf8_value_cb(p, cb_read_byte, &ch);
@ -221,7 +250,7 @@ millis_t next_button_update_ms;
x = (LCD_WIDTH - plen - slen) / 2; x = (LCD_WIDTH - plen - slen) / 2;
y = LCD_HEIGHT > 3 ? 1 : 0; y = LCD_HEIGHT > 3 ? 1 : 0;
} }
wrap_string_P(x, y, pref); wrap_string_P(x, y, pref, true);
if (string) { if (string) {
if (x) { x = 0; y++; } // Move to the start of the next line if (x) { x = 0; y++; } // Move to the start of the next line
wrap_string(x, y, string); wrap_string(x, y, string);

6
Marlin/src/lcd/ultralcd.h

@ -74,9 +74,9 @@
#include "fontutils.h" #include "fontutils.h"
void _wrap_string(uint8_t &x, uint8_t &y, const char * const string, read_byte_cb_t cb_read_byte); void _wrap_string(uint8_t &x, uint8_t &y, const char * const string, read_byte_cb_t cb_read_byte, const bool wordwrap=false);
inline void wrap_string_P(uint8_t &x, uint8_t &y, PGM_P const pstr) { _wrap_string(x, y, pstr, read_byte_rom); } inline void wrap_string_P(uint8_t &x, uint8_t &y, PGM_P const pstr, const bool wordwrap=false) { _wrap_string(x, y, pstr, read_byte_rom, wordwrap); }
inline void wrap_string(uint8_t &x, uint8_t &y, const char * const string) { _wrap_string(x, y, string, read_byte_ram); } inline void wrap_string(uint8_t &x, uint8_t &y, const char * const string, const bool wordwrap=false) { _wrap_string(x, y, string, read_byte_ram, wordwrap); }
#if ENABLED(SDSUPPORT) #if ENABLED(SDSUPPORT)
#include "../sd/cardreader.h" #include "../sd/cardreader.h"

66
config/default/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/default/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/3DFabXYZ/Migbot/Configuration.h

@ -834,72 +834,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/3DFabXYZ/Migbot/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/AlephObjects/TAZ4/Configuration.h

@ -848,72 +848,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/AlephObjects/TAZ4/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/AliExpress/CL-260/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

66
config/examples/AliExpress/UM2pExt/Configuration.h

@ -839,72 +839,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/AliExpress/UM2pExt/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Anet/A2/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Anet/A2/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Anet/A2plus/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Anet/A2plus/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Anet/A6/Configuration.h

@ -875,72 +875,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Anet/A6/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Anet/A8/Configuration.h

@ -841,72 +841,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Anet/A8/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Anet/A8plus/Configuration.h

@ -839,72 +839,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Anet/A8plus/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Anet/E16/Configuration.h

@ -840,72 +840,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Anet/E16/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/AnyCubic/i3/Configuration.h

@ -838,72 +838,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
#define BLTOUCH #define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/AnyCubic/i3/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/ArmEd/Configuration.h

@ -829,72 +829,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/ArmEd/Configuration_adv.h

@ -528,6 +528,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Azteeg/X5GT/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

66
config/examples/BIBO/TouchX/cyclops/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/BIBO/TouchX/cyclops/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/BIBO/TouchX/default/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/BIBO/TouchX/default/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/BQ/Hephestos/Configuration.h

@ -816,72 +816,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/BQ/Hephestos/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/BQ/Hephestos_2/Configuration.h

@ -829,72 +829,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/BQ/Hephestos_2/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/BQ/WITBOX/Configuration.h

@ -816,72 +816,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/BQ/WITBOX/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Cartesio/Configuration.h

@ -827,72 +827,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Cartesio/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/CR-10/Configuration.h

@ -838,72 +838,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/CR-10/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/CR-10S/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/CR-10S/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/CR-10_5S/Configuration.h

@ -829,72 +829,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/CR-10_5S/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/CR-10mini/Configuration.h

@ -847,72 +847,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/CR-10mini/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/CR-8/Configuration.h

@ -838,72 +838,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/CR-8/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/Ender-2/Configuration.h

@ -832,72 +832,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/Ender-2/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/Ender-3/Configuration.h

@ -832,72 +832,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/Ender-3/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Creality/Ender-4/Configuration.h

@ -838,72 +838,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Creality/Ender-4/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

67
config/examples/Dagoma/Disco Ultimate/Configuration_adv.h

@ -523,6 +523,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Einstart-S/Configuration.h

@ -837,72 +837,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Einstart-S/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Felix/Configuration.h

@ -810,72 +810,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Felix/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Felix/DUAL/Configuration.h

@ -810,72 +810,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

66
config/examples/FlashForge/CreatorPro/Configuration.h

@ -820,72 +820,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/FlashForge/CreatorPro/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/FolgerTech/i3-2020/Configuration.h

@ -834,72 +834,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/FolgerTech/i3-2020/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Formbot/Raptor/Configuration.h

@ -911,72 +911,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
#define BLTOUCH #define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Formbot/Raptor/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

67
config/examples/Formbot/T_Rex_2+/Configuration.h

@ -857,73 +857,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
#define BLTOUCH #define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Formbot/T_Rex_2+/Configuration_adv.h

@ -528,6 +528,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Formbot/T_Rex_3/Configuration.h

@ -844,72 +844,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
#define BLTOUCH #define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Formbot/T_Rex_3/Configuration_adv.h

@ -528,6 +528,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Geeetech/A10M/Configuration.h

@ -811,72 +811,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
#define BLTOUCH_DELAY 200
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Geeetech/A10M/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
#define BLTOUCH_DELAY 200
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Geeetech/A20M/Configuration.h

@ -811,72 +811,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
#define BLTOUCH_DELAY 200
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Geeetech/A20M/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
#define BLTOUCH_DELAY 200
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Geeetech/GT2560/Configuration.h

@ -843,72 +843,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

3
config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h

@ -828,9 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
//#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed
#endif
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

66
config/examples/Geeetech/MeCreator2/Configuration.h

@ -835,72 +835,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Geeetech/MeCreator2/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h

@ -848,72 +848,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
#define BLTOUCH #define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

66
config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h

@ -848,72 +848,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

66
config/examples/Geeetech/Prusa i3 Pro C/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Geeetech/Prusa i3 Pro W/Configuration.h

@ -828,72 +828,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Infitary/i3-M508/Configuration.h

@ -832,72 +832,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Infitary/i3-M508/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/JGAurora/A5/Configuration.h

@ -840,72 +840,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/JGAurora/A5/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/MakerParts/Configuration.h

@ -848,72 +848,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/MakerParts/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Malyan/M150/Configuration.h

@ -848,72 +848,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Malyan/M150/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

66
config/examples/Malyan/M200/Configuration.h

@ -827,72 +827,6 @@
* The BLTouch probe uses a Hall effect sensor and emulates a servo. * The BLTouch probe uses a Hall effect sensor and emulates a servo.
*/ */
//#define BLTOUCH //#define BLTOUCH
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
//#define SOLENOID_PROBE //#define SOLENOID_PROBE

67
config/examples/Malyan/M200/Configuration_adv.h

@ -524,6 +524,73 @@
// Enable this if X or Y can't home without homing the other axis first. // Enable this if X or Y can't home without homing the other axis first.
//#define CODEPENDENT_XY_HOMING //#define CODEPENDENT_XY_HOMING
#if ENABLED(BLTOUCH)
/**
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
* Do not activate settings that the probe might not understand. Clones might misunderstand
* advanced commands.
*
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
* check the wiring of the BROWN, RED and ORANGE wires.
*
* Note: If the trigger signal of your probe is not being recognized, it has been very often
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
* like they would be with a real switch. So please check the wiring first.
*
* Settings for all BLTouch and clone probes:
*/
// Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed.
//#define BLTOUCH_DELAY 500
/**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
*/
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE
/**
* Settings for BLTouch Smart 3.0 and 3.1
* Summary:
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
* - High-Speed mode
* - Disable LCD voltage options
*/
/**
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
* If disabled, OD mode is the hard-coded default on 3.0
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
* differs, a mode set eeprom write will be completed at initialization.
* Use the option below to force an eeprom write to a V3.1 probe regardless.
*/
//#define BLTOUCH_SET_5V_MODE
/**
* Safety: Activate if connecting a probe with an unknown voltage mode.
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
* To preserve the life of the probe, use this once then turn it off and re-flash.
*/
//#define BLTOUCH_FORCE_MODE_SET
/**
* Use "HIGH SPEED" mode for probing.
* Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems.
* This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function
* If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state.
*/
//#define BLTOUCH_HS_MODE
// Safety: Enable voltage mode settings in the LCD menu.
//#define BLTOUCH_LCD_VOLTAGE_MENU
#endif // BLTOUCH
/** /**
* Z Steppers Auto-Alignment * Z Steppers Auto-Alignment
* Add the G34 command to align multiple Z steppers using a bed probe. * Add the G34 command to align multiple Z steppers using a bed probe.

Some files were not shown because too many files changed in this diff

Loading…
Cancel
Save