@ -171,7 +171,7 @@ |
|
|
|
// Use internal reference voltage for current calculations. This is the default.
|
|
|
|
// Following values from Trinamic's spreadsheet with values for a NEMA17 (42BYGHW609)
|
|
|
|
// https://www.trinamic.com/products/integrated-circuits/details/tmc2130/
|
|
|
|
void tmc2130_init(TMC2130Stepper &st, const uint16_t microsteps, const uint32_t thrs, const uint32_t spmm) { |
|
|
|
void tmc2130_init(TMC2130Stepper &st, const uint16_t microsteps, const uint32_t thrs, const float &spmm) { |
|
|
|
st.begin(); |
|
|
|
st.setCurrent(st.getCurrent(), R_SENSE, HOLD_MULTIPLIER); |
|
|
|
st.microsteps(microsteps); |
|
|
@ -199,7 +199,7 @@ |
|
|
|
#define _TMC2130_INIT(ST, SPMM) tmc2130_init(stepper##ST, ST##_MICROSTEPS, ST##_HYBRID_THRESHOLD, SPMM) |
|
|
|
|
|
|
|
void tmc2130_init() { |
|
|
|
constexpr uint16_t steps_per_mm[] = DEFAULT_AXIS_STEPS_PER_UNIT; |
|
|
|
constexpr float steps_per_mm[] = DEFAULT_AXIS_STEPS_PER_UNIT; |
|
|
|
#if ENABLED(X_IS_TMC2130) |
|
|
|
_TMC2130_INIT( X, steps_per_mm[X_AXIS]); |
|
|
|
#if ENABLED(SENSORLESS_HOMING) |
|
|
|