@ -73,27 +73,41 @@ const short temptable_1[][2] PROGMEM = { |
|
|
|
#endif |
|
|
|
#if (THERMISTORHEATER_0 == 2) || (THERMISTORHEATER_1 == 2) || (THERMISTORHEATER_2 == 2) || (THERMISTORBED == 2) //200k bed thermistor
|
|
|
|
const short temptable_2[][2] PROGMEM = { |
|
|
|
//200k ATC Semitec 204GT-2
|
|
|
|
//Verified by linagee. Source: http://shop.arcol.hu/static/datasheets/thermistors.pdf
|
|
|
|
// Calculated using 4.7kohm pullup, voltage divider math, and manufacturer provided temp/resistance
|
|
|
|
{1*OVERSAMPLENR, 848}, |
|
|
|
{54*OVERSAMPLENR, 275}, |
|
|
|
{107*OVERSAMPLENR, 228}, |
|
|
|
{160*OVERSAMPLENR, 202}, |
|
|
|
{213*OVERSAMPLENR, 185}, |
|
|
|
{266*OVERSAMPLENR, 171}, |
|
|
|
{319*OVERSAMPLENR, 160}, |
|
|
|
{372*OVERSAMPLENR, 150}, |
|
|
|
{425*OVERSAMPLENR, 141}, |
|
|
|
{478*OVERSAMPLENR, 133}, |
|
|
|
{531*OVERSAMPLENR, 125}, |
|
|
|
{584*OVERSAMPLENR, 118}, |
|
|
|
{637*OVERSAMPLENR, 110}, |
|
|
|
{690*OVERSAMPLENR, 103}, |
|
|
|
{743*OVERSAMPLENR, 95}, |
|
|
|
{796*OVERSAMPLENR, 86}, |
|
|
|
{849*OVERSAMPLENR, 77}, |
|
|
|
{902*OVERSAMPLENR, 65}, |
|
|
|
{955*OVERSAMPLENR, 49}, |
|
|
|
{1008*OVERSAMPLENR, 17}, |
|
|
|
{1020*OVERSAMPLENR, 0} //safety
|
|
|
|
{30*OVERSAMPLENR, 300}, //top rating 300C
|
|
|
|
{34*OVERSAMPLENR, 290}, |
|
|
|
{39*OVERSAMPLENR, 280}, |
|
|
|
{46*OVERSAMPLENR, 270}, |
|
|
|
{53*OVERSAMPLENR, 260}, |
|
|
|
{63*OVERSAMPLENR, 250}, |
|
|
|
{74*OVERSAMPLENR, 240}, |
|
|
|
{87*OVERSAMPLENR, 230}, |
|
|
|
{104*OVERSAMPLENR, 220}, |
|
|
|
{124*OVERSAMPLENR, 210}, |
|
|
|
{148*OVERSAMPLENR, 200}, |
|
|
|
{176*OVERSAMPLENR, 190}, |
|
|
|
{211*OVERSAMPLENR, 180}, |
|
|
|
{252*OVERSAMPLENR, 170}, |
|
|
|
{301*OVERSAMPLENR, 160}, |
|
|
|
{357*OVERSAMPLENR, 150}, |
|
|
|
{420*OVERSAMPLENR, 140}, |
|
|
|
{489*OVERSAMPLENR, 130}, |
|
|
|
{562*OVERSAMPLENR, 120}, |
|
|
|
{636*OVERSAMPLENR, 110}, |
|
|
|
{708*OVERSAMPLENR, 100}, |
|
|
|
{775*OVERSAMPLENR, 90}, |
|
|
|
{835*OVERSAMPLENR, 80}, |
|
|
|
{884*OVERSAMPLENR, 70}, |
|
|
|
{924*OVERSAMPLENR, 60}, |
|
|
|
{955*OVERSAMPLENR, 50}, |
|
|
|
{977*OVERSAMPLENR, 40}, |
|
|
|
{993*OVERSAMPLENR, 30}, |
|
|
|
{1004*OVERSAMPLENR, 20}, |
|
|
|
{1012*OVERSAMPLENR, 10}, |
|
|
|
{1016*OVERSAMPLENR, 0}, |
|
|
|
}; |
|
|
|
|
|
|
|
#endif |
|
|
@ -157,73 +171,48 @@ const short temptable_4[][2] PROGMEM = { |
|
|
|
|
|
|
|
#if (THERMISTORHEATER_0 == 5) || (THERMISTORHEATER_1 == 5) || (THERMISTORHEATER_2 == 5) || (THERMISTORBED == 5) //100k ParCan thermistor (104GT-2)
|
|
|
|
const short temptable_5[][2] PROGMEM = { |
|
|
|
{1*OVERSAMPLENR, 713}, |
|
|
|
{18*OVERSAMPLENR, 316}, |
|
|
|
{35*OVERSAMPLENR, 266}, |
|
|
|
{52*OVERSAMPLENR, 239}, |
|
|
|
{69*OVERSAMPLENR, 221}, |
|
|
|
{86*OVERSAMPLENR, 208}, |
|
|
|
{103*OVERSAMPLENR, 197}, |
|
|
|
{120*OVERSAMPLENR, 188}, |
|
|
|
{137*OVERSAMPLENR, 181}, |
|
|
|
{154*OVERSAMPLENR, 174}, |
|
|
|
{171*OVERSAMPLENR, 169}, |
|
|
|
{188*OVERSAMPLENR, 163}, |
|
|
|
{205*OVERSAMPLENR, 159}, |
|
|
|
{222*OVERSAMPLENR, 154}, |
|
|
|
{239*OVERSAMPLENR, 150}, |
|
|
|
{256*OVERSAMPLENR, 147}, |
|
|
|
{273*OVERSAMPLENR, 143}, |
|
|
|
{290*OVERSAMPLENR, 140}, |
|
|
|
{307*OVERSAMPLENR, 136}, |
|
|
|
{324*OVERSAMPLENR, 133}, |
|
|
|
{341*OVERSAMPLENR, 130}, |
|
|
|
{358*OVERSAMPLENR, 128}, |
|
|
|
{375*OVERSAMPLENR, 125}, |
|
|
|
{392*OVERSAMPLENR, 122}, |
|
|
|
{409*OVERSAMPLENR, 120}, |
|
|
|
{426*OVERSAMPLENR, 117}, |
|
|
|
{443*OVERSAMPLENR, 115}, |
|
|
|
{460*OVERSAMPLENR, 112}, |
|
|
|
{477*OVERSAMPLENR, 110}, |
|
|
|
{494*OVERSAMPLENR, 108}, |
|
|
|
{511*OVERSAMPLENR, 106}, |
|
|
|
{528*OVERSAMPLENR, 103}, |
|
|
|
{545*OVERSAMPLENR, 101}, |
|
|
|
{562*OVERSAMPLENR, 99}, |
|
|
|
{579*OVERSAMPLENR, 97}, |
|
|
|
{596*OVERSAMPLENR, 95}, |
|
|
|
{613*OVERSAMPLENR, 92}, |
|
|
|
{630*OVERSAMPLENR, 90}, |
|
|
|
{647*OVERSAMPLENR, 88}, |
|
|
|
{664*OVERSAMPLENR, 86}, |
|
|
|
{681*OVERSAMPLENR, 84}, |
|
|
|
{698*OVERSAMPLENR, 81}, |
|
|
|
{715*OVERSAMPLENR, 79}, |
|
|
|
{732*OVERSAMPLENR, 77}, |
|
|
|
{749*OVERSAMPLENR, 75}, |
|
|
|
{766*OVERSAMPLENR, 72}, |
|
|
|
{783*OVERSAMPLENR, 70}, |
|
|
|
{800*OVERSAMPLENR, 67}, |
|
|
|
{817*OVERSAMPLENR, 64}, |
|
|
|
{834*OVERSAMPLENR, 61}, |
|
|
|
{851*OVERSAMPLENR, 58}, |
|
|
|
{868*OVERSAMPLENR, 55}, |
|
|
|
{885*OVERSAMPLENR, 52}, |
|
|
|
{902*OVERSAMPLENR, 48}, |
|
|
|
{919*OVERSAMPLENR, 44}, |
|
|
|
{936*OVERSAMPLENR, 40}, |
|
|
|
{953*OVERSAMPLENR, 34}, |
|
|
|
{970*OVERSAMPLENR, 28}, |
|
|
|
{987*OVERSAMPLENR, 20}, |
|
|
|
{1004*OVERSAMPLENR, 8}, |
|
|
|
{1021*OVERSAMPLENR, 0} |
|
|
|
// ATC Semitec 104GT-2 (Used in ParCan)
|
|
|
|
// Verified by linagee. Source: http://shop.arcol.hu/static/datasheets/thermistors.pdf
|
|
|
|
// Calculated using 4.7kohm pullup, voltage divider math, and manufacturer provided temp/resistance
|
|
|
|
{1*OVERSAMPLENR, 713}, |
|
|
|
{17*OVERSAMPLENR, 300}, //top rating 300C
|
|
|
|
{20*OVERSAMPLENR, 290}, |
|
|
|
{23*OVERSAMPLENR, 280}, |
|
|
|
{27*OVERSAMPLENR, 270}, |
|
|
|
{31*OVERSAMPLENR, 260}, |
|
|
|
{37*OVERSAMPLENR, 250}, |
|
|
|
{43*OVERSAMPLENR, 240}, |
|
|
|
{51*OVERSAMPLENR, 230}, |
|
|
|
{61*OVERSAMPLENR, 220}, |
|
|
|
{73*OVERSAMPLENR, 210}, |
|
|
|
{87*OVERSAMPLENR, 200}, |
|
|
|
{106*OVERSAMPLENR, 190}, |
|
|
|
{128*OVERSAMPLENR, 180}, |
|
|
|
{155*OVERSAMPLENR, 170}, |
|
|
|
{189*OVERSAMPLENR, 160}, |
|
|
|
{230*OVERSAMPLENR, 150}, |
|
|
|
{278*OVERSAMPLENR, 140}, |
|
|
|
{336*OVERSAMPLENR, 130}, |
|
|
|
{402*OVERSAMPLENR, 120}, |
|
|
|
{476*OVERSAMPLENR, 110}, |
|
|
|
{554*OVERSAMPLENR, 100}, |
|
|
|
{635*OVERSAMPLENR, 90}, |
|
|
|
{713*OVERSAMPLENR, 80}, |
|
|
|
{784*OVERSAMPLENR, 70}, |
|
|
|
{846*OVERSAMPLENR, 60}, |
|
|
|
{897*OVERSAMPLENR, 50}, |
|
|
|
{937*OVERSAMPLENR, 40}, |
|
|
|
{966*OVERSAMPLENR, 30}, |
|
|
|
{986*OVERSAMPLENR, 20}, |
|
|
|
{1000*OVERSAMPLENR, 10}, |
|
|
|
{1010*OVERSAMPLENR, 0} |
|
|
|
}; |
|
|
|
#endif |
|
|
|
|
|
|
|
#if (THERMISTORHEATER_0 == 6) || (THERMISTORHEATER_1 == 6) || (THERMISTORHEATER_2 == 6) || (THERMISTORBED == 6) // 100k Epcos thermistor
|
|
|
|
const short temptable_6[][2] PROGMEM = { |
|
|
|
{28*OVERSAMPLENR, 250}, |
|
|
|
{1*OVERSAMPLENR, 350}, |
|
|
|
{28*OVERSAMPLENR, 250}, //top rating 250C
|
|
|
|
{31*OVERSAMPLENR, 245}, |
|
|
|
{35*OVERSAMPLENR, 240}, |
|
|
|
{39*OVERSAMPLENR, 235}, |
|
|
@ -264,7 +253,8 @@ const short temptable_6[][2] PROGMEM = { |
|
|
|
|
|
|
|
#if (THERMISTORHEATER_0 == 7) || (THERMISTORHEATER_1 == 7) || (THERMISTORHEATER_2 == 7) || (THERMISTORBED == 7) // 100k Honeywell 135-104LAG-J01
|
|
|
|
const short temptable_7[][2] PROGMEM = { |
|
|
|
{46*OVERSAMPLENR, 270}, |
|
|
|
{1*OVERSAMPLENR, 500}, |
|
|
|
{46*OVERSAMPLENR, 270}, //top rating 300C
|
|
|
|
{50*OVERSAMPLENR, 265}, |
|
|
|
{54*OVERSAMPLENR, 260}, |
|
|
|
{58*OVERSAMPLENR, 255}, |
|
|
@ -321,6 +311,150 @@ const short temptable_7[][2] PROGMEM = { |
|
|
|
}; |
|
|
|
#endif |
|
|
|
|
|
|
|
#if (THERMISTORHEATER_0 == 51) || (THERMISTORHEATER_1 == 51) || (THERMISTORHEATER_2 == 51) || (THERMISTORBED == 51) |
|
|
|
// 100k EPCOS (WITH 1kohm RESISTOR FOR PULLUP, R9 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!)
|
|
|
|
// Verified by linagee.
|
|
|
|
// Calculated using 1kohm pullup, voltage divider math, and manufacturer provided temp/resistance
|
|
|
|
// Advantage: Twice the resolution and better linearity from 150C to 200C
|
|
|
|
const short temptable_51[][2] PROGMEM = { |
|
|
|
{1*OVERSAMPLENR, 350}, |
|
|
|
{190*OVERSAMPLENR, 250}, //top rating 250C
|
|
|
|
{203*OVERSAMPLENR, 245}, |
|
|
|
{217*OVERSAMPLENR, 240}, |
|
|
|
{232*OVERSAMPLENR, 235}, |
|
|
|
{248*OVERSAMPLENR, 230}, |
|
|
|
{265*OVERSAMPLENR, 225}, |
|
|
|
{283*OVERSAMPLENR, 220}, |
|
|
|
{302*OVERSAMPLENR, 215}, |
|
|
|
{322*OVERSAMPLENR, 210}, |
|
|
|
{344*OVERSAMPLENR, 205}, |
|
|
|
{366*OVERSAMPLENR, 200}, |
|
|
|
{390*OVERSAMPLENR, 195}, |
|
|
|
{415*OVERSAMPLENR, 190}, |
|
|
|
{440*OVERSAMPLENR, 185}, |
|
|
|
{467*OVERSAMPLENR, 180}, |
|
|
|
{494*OVERSAMPLENR, 175}, |
|
|
|
{522*OVERSAMPLENR, 170}, |
|
|
|
{551*OVERSAMPLENR, 165}, |
|
|
|
{580*OVERSAMPLENR, 160}, |
|
|
|
{609*OVERSAMPLENR, 155}, |
|
|
|
{638*OVERSAMPLENR, 150}, |
|
|
|
{666*OVERSAMPLENR, 145}, |
|
|
|
{695*OVERSAMPLENR, 140}, |
|
|
|
{722*OVERSAMPLENR, 135}, |
|
|
|
{749*OVERSAMPLENR, 130}, |
|
|
|
{775*OVERSAMPLENR, 125}, |
|
|
|
{800*OVERSAMPLENR, 120}, |
|
|
|
{823*OVERSAMPLENR, 115}, |
|
|
|
{845*OVERSAMPLENR, 110}, |
|
|
|
{865*OVERSAMPLENR, 105}, |
|
|
|
{884*OVERSAMPLENR, 100}, |
|
|
|
{901*OVERSAMPLENR, 95}, |
|
|
|
{917*OVERSAMPLENR, 90}, |
|
|
|
{932*OVERSAMPLENR, 85}, |
|
|
|
{944*OVERSAMPLENR, 80}, |
|
|
|
{956*OVERSAMPLENR, 75}, |
|
|
|
{966*OVERSAMPLENR, 70}, |
|
|
|
{975*OVERSAMPLENR, 65}, |
|
|
|
{982*OVERSAMPLENR, 60}, |
|
|
|
{989*OVERSAMPLENR, 55}, |
|
|
|
{995*OVERSAMPLENR, 50}, |
|
|
|
{1000*OVERSAMPLENR, 45}, |
|
|
|
{1004*OVERSAMPLENR, 40}, |
|
|
|
{1007*OVERSAMPLENR, 35}, |
|
|
|
{1010*OVERSAMPLENR, 30}, |
|
|
|
{1013*OVERSAMPLENR, 25}, |
|
|
|
{1015*OVERSAMPLENR, 20}, |
|
|
|
{1017*OVERSAMPLENR, 15}, |
|
|
|
{1018*OVERSAMPLENR, 10}, |
|
|
|
{1019*OVERSAMPLENR, 5}, |
|
|
|
{1020*OVERSAMPLENR, 0}, |
|
|
|
{1021*OVERSAMPLENR, -5} |
|
|
|
}; |
|
|
|
#endif |
|
|
|
|
|
|
|
#if (THERMISTORHEATER_0 == 52) || (THERMISTORHEATER_1 == 52) || (THERMISTORHEATER_2 == 52) || (THERMISTORBED == 52) |
|
|
|
// 200k ATC Semitec 204GT-2 (WITH 1kohm RESISTOR FOR PULLUP, R9 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!)
|
|
|
|
// Verified by linagee. Source: http://shop.arcol.hu/static/datasheets/thermistors.pdf
|
|
|
|
// Calculated using 1kohm pullup, voltage divider math, and manufacturer provided temp/resistance
|
|
|
|
// Advantage: More resolution and better linearity from 150C to 200C
|
|
|
|
const short temptable_52[][2] PROGMEM = { |
|
|
|
{1*OVERSAMPLENR, 500}, |
|
|
|
{125*OVERSAMPLENR, 300}, //top rating 300C
|
|
|
|
{142*OVERSAMPLENR, 290}, |
|
|
|
{162*OVERSAMPLENR, 280}, |
|
|
|
{185*OVERSAMPLENR, 270}, |
|
|
|
{211*OVERSAMPLENR, 260}, |
|
|
|
{240*OVERSAMPLENR, 250}, |
|
|
|
{274*OVERSAMPLENR, 240}, |
|
|
|
{312*OVERSAMPLENR, 230}, |
|
|
|
{355*OVERSAMPLENR, 220}, |
|
|
|
{401*OVERSAMPLENR, 210}, |
|
|
|
{452*OVERSAMPLENR, 200}, |
|
|
|
{506*OVERSAMPLENR, 190}, |
|
|
|
{563*OVERSAMPLENR, 180}, |
|
|
|
{620*OVERSAMPLENR, 170}, |
|
|
|
{677*OVERSAMPLENR, 160}, |
|
|
|
{732*OVERSAMPLENR, 150}, |
|
|
|
{783*OVERSAMPLENR, 140}, |
|
|
|
{830*OVERSAMPLENR, 130}, |
|
|
|
{871*OVERSAMPLENR, 120}, |
|
|
|
{906*OVERSAMPLENR, 110}, |
|
|
|
{935*OVERSAMPLENR, 100}, |
|
|
|
{958*OVERSAMPLENR, 90}, |
|
|
|
{976*OVERSAMPLENR, 80}, |
|
|
|
{990*OVERSAMPLENR, 70}, |
|
|
|
{1000*OVERSAMPLENR, 60}, |
|
|
|
{1008*OVERSAMPLENR, 50}, |
|
|
|
{1013*OVERSAMPLENR, 40}, |
|
|
|
{1017*OVERSAMPLENR, 30}, |
|
|
|
{1019*OVERSAMPLENR, 20}, |
|
|
|
{1021*OVERSAMPLENR, 10}, |
|
|
|
{1022*OVERSAMPLENR, 0} |
|
|
|
}; |
|
|
|
#endif |
|
|
|
|
|
|
|
#if (THERMISTORHEATER_0 == 55) || (THERMISTORHEATER_1 == 55) || (THERMISTORHEATER_2 == 55) || (THERMISTORBED == 55) |
|
|
|
// 100k ATC Semitec 104GT-2 (Used on ParCan) (WITH 1kohm RESISTOR FOR PULLUP, R9 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!)
|
|
|
|
// Verified by linagee. Source: http://shop.arcol.hu/static/datasheets/thermistors.pdf
|
|
|
|
// Calculated using 1kohm pullup, voltage divider math, and manufacturer provided temp/resistance
|
|
|
|
// Advantage: More resolution and better linearity from 150C to 200C
|
|
|
|
const short temptable_52[][2] PROGMEM = { |
|
|
|
{1*OVERSAMPLENR, 500}, |
|
|
|
{76*OVERSAMPLENR, 300}, |
|
|
|
{87*OVERSAMPLENR, 290}, |
|
|
|
{100*OVERSAMPLENR, 280}, |
|
|
|
{114*OVERSAMPLENR, 270}, |
|
|
|
{131*OVERSAMPLENR, 260}, |
|
|
|
{152*OVERSAMPLENR, 250}, |
|
|
|
{175*OVERSAMPLENR, 240}, |
|
|
|
{202*OVERSAMPLENR, 230}, |
|
|
|
{234*OVERSAMPLENR, 220}, |
|
|
|
{271*OVERSAMPLENR, 210}, |
|
|
|
{312*OVERSAMPLENR, 200}, |
|
|
|
{359*OVERSAMPLENR, 190}, |
|
|
|
{411*OVERSAMPLENR, 180}, |
|
|
|
{467*OVERSAMPLENR, 170}, |
|
|
|
{527*OVERSAMPLENR, 160}, |
|
|
|
{590*OVERSAMPLENR, 150}, |
|
|
|
{652*OVERSAMPLENR, 140}, |
|
|
|
{713*OVERSAMPLENR, 130}, |
|
|
|
{770*OVERSAMPLENR, 120}, |
|
|
|
{822*OVERSAMPLENR, 110}, |
|
|
|
{867*OVERSAMPLENR, 100}, |
|
|
|
{905*OVERSAMPLENR, 90}, |
|
|
|
{936*OVERSAMPLENR, 80}, |
|
|
|
{961*OVERSAMPLENR, 70}, |
|
|
|
{979*OVERSAMPLENR, 60}, |
|
|
|
{993*OVERSAMPLENR, 50}, |
|
|
|
{1003*OVERSAMPLENR, 40}, |
|
|
|
{1010*OVERSAMPLENR, 30}, |
|
|
|
{1015*OVERSAMPLENR, 20}, |
|
|
|
{1018*OVERSAMPLENR, 10}, |
|
|
|
{1020*OVERSAMPLENR, 0} |
|
|
|
}; |
|
|
|
#endif |
|
|
|
|
|
|
|
#define _TT_NAME(_N) temptable_ ## _N |
|
|
|
#define TT_NAME(_N) _TT_NAME(_N) |
|
|
|
|
|
|
|