Adjust for timing shift on Max7219 displays on AVR's

Something has shifted.   The previous timing delays on the Max7219 debug displays is too tight without this correction.
I suspect something has been optimized and roughly 50ns of needed setup and hold time has disappeared.
This corrects the issue and the display results are clean again.
vanilla_fb_2.0.x
Roxy-3D 5 years ago
committed by GitHub
parent
commit
5d515c3a2f
No known key found for this signature in database GPG Key ID: 4AEE18F83AFDEB23
  1. 2
      Marlin/src/feature/max7219.cpp

2
Marlin/src/feature/max7219.cpp

@ -121,7 +121,7 @@ uint8_t Max7219::suspended; // = 0;
#define CRITICAL_SECTION_START() NOOP
#define CRITICAL_SECTION_END() NOOP
#else
#define SIG_DELAY() DELAY_NS(188) // Delay for 0.1875µs (16MHz AVR) or 0.15µs (20MHz AVR)
#define SIG_DELAY() DELAY_NS(250) // Delay for 0.1875µs (16MHz AVR) or 0.15µs (20MHz AVR)
#endif