@ -45,9 +45,44 @@ typedef struct { |
|
|
* measurement errors/shifts due to changed temperature. |
|
|
* measurement errors/shifts due to changed temperature. |
|
|
*/ |
|
|
*/ |
|
|
|
|
|
|
|
|
|
|
|
// Probe temperature calibration constants
|
|
|
|
|
|
#ifndef PTC_SAMPLE_COUNT |
|
|
|
|
|
#define PTC_SAMPLE_COUNT 10U |
|
|
|
|
|
#endif |
|
|
|
|
|
#ifndef PTC_SAMPLE_RES |
|
|
|
|
|
#define PTC_SAMPLE_RES 5.0f |
|
|
|
|
|
#endif |
|
|
|
|
|
#ifndef PTC_SAMPLE_START |
|
|
|
|
|
#define PTC_SAMPLE_START 30.0f |
|
|
|
|
|
#endif |
|
|
|
|
|
#define PTC_SAMPLE_END ((PTC_SAMPLE_START) + (PTC_SAMPLE_COUNT) * (PTC_SAMPLE_RES)) |
|
|
|
|
|
|
|
|
|
|
|
// Bed temperature calibration constants
|
|
|
|
|
|
#ifndef BTC_PROBE_TEMP |
|
|
|
|
|
#define BTC_PROBE_TEMP 30.0f |
|
|
|
|
|
#endif |
|
|
|
|
|
#ifndef BTC_SAMPLE_COUNT |
|
|
|
|
|
#define BTC_SAMPLE_COUNT 10U |
|
|
|
|
|
#endif |
|
|
|
|
|
#ifndef BTC_SAMPLE_STEP |
|
|
|
|
|
#define BTC_SAMPLE_RES 5.0f |
|
|
|
|
|
#endif |
|
|
|
|
|
#ifndef BTC_SAMPLE_START |
|
|
|
|
|
#define BTC_SAMPLE_START 60.0f |
|
|
|
|
|
#endif |
|
|
|
|
|
#define BTC_SAMPLE_END ((BTC_SAMPLE_START) + (BTC_SAMPLE_COUNT) * (BTC_SAMPLE_RES)) |
|
|
|
|
|
|
|
|
|
|
|
#ifndef PTC_PROBE_HEATING_OFFSET |
|
|
|
|
|
#define PTC_PROBE_HEATING_OFFSET 0.5f |
|
|
|
|
|
#endif |
|
|
|
|
|
|
|
|
|
|
|
#ifndef PTC_PROBE_RAISE |
|
|
|
|
|
#define PTC_PROBE_RAISE 10.0f |
|
|
|
|
|
#endif |
|
|
|
|
|
|
|
|
static constexpr temp_calib_t cali_info_init[TSI_COUNT] = { |
|
|
static constexpr temp_calib_t cali_info_init[TSI_COUNT] = { |
|
|
{ 10, 5, 30, 30 + 10 * 5 }, // Probe
|
|
|
{ PTC_SAMPLE_COUNT, PTC_SAMPLE_RES, PTC_SAMPLE_START, PTC_SAMPLE_END }, // Probe
|
|
|
{ 10, 5, 60, 60 + 10 * 5 }, // Bed
|
|
|
{ BTC_SAMPLE_COUNT, BTC_SAMPLE_RES, BTC_SAMPLE_START, BTC_SAMPLE_END }, // Bed
|
|
|
#if ENABLED(USE_TEMP_EXT_COMPENSATION) |
|
|
#if ENABLED(USE_TEMP_EXT_COMPENSATION) |
|
|
{ 20, 5, 180, 180 + 5 * 20 } // Extruder
|
|
|
{ 20, 5, 180, 180 + 5 * 20 } // Extruder
|
|
|
#endif |
|
|
#endif |
|
@ -66,7 +101,7 @@ class ProbeTempComp { |
|
|
//measure_point = { 12.0f, 7.3f }; // Coordinates for the MK52 magnetic heatbed
|
|
|
//measure_point = { 12.0f, 7.3f }; // Coordinates for the MK52 magnetic heatbed
|
|
|
|
|
|
|
|
|
static constexpr int probe_calib_bed_temp = BED_MAX_TARGET, // Bed temperature while calibrating probe
|
|
|
static constexpr int probe_calib_bed_temp = BED_MAX_TARGET, // Bed temperature while calibrating probe
|
|
|
bed_calib_probe_temp = 30; // Probe temperature while calibrating bed
|
|
|
bed_calib_probe_temp = BTC_PROBE_TEMP; // Probe temperature while calibrating bed
|
|
|
|
|
|
|
|
|
static int16_t *sensor_z_offsets[TSI_COUNT], |
|
|
static int16_t *sensor_z_offsets[TSI_COUNT], |
|
|
z_offsets_probe[cali_info_init[TSI_PROBE].measurements], // (µm)
|
|
|
z_offsets_probe[cali_info_init[TSI_PROBE].measurements], // (µm)
|
|
|