@ -1993,7 +1993,7 @@ static void clean_up_after_endstop_or_probe_move() { |
|
|
|
|
|
|
|
// Do a single Z probe and return with current_position[Z_AXIS]
|
|
|
|
// at the height where the probe triggered.
|
|
|
|
static void run_z_probe() { |
|
|
|
static float run_z_probe() { |
|
|
|
|
|
|
|
float old_feedrate = feedrate; |
|
|
|
|
|
|
@ -2076,6 +2076,8 @@ static void clean_up_after_endstop_or_probe_move() { |
|
|
|
#endif // !DELTA
|
|
|
|
|
|
|
|
feedrate = old_feedrate; |
|
|
|
|
|
|
|
return current_position[Z_AXIS]; |
|
|
|
} |
|
|
|
|
|
|
|
#endif // HAS_BED_PROBE
|
|
|
@ -2134,8 +2136,7 @@ static void clean_up_after_endstop_or_probe_move() { |
|
|
|
deploy_z_probe(); |
|
|
|
} |
|
|
|
|
|
|
|
run_z_probe(); |
|
|
|
float measured_z = current_position[Z_AXIS]; |
|
|
|
float measured_z = run_z_probe(); |
|
|
|
|
|
|
|
if (probe_action & ProbeStow) { |
|
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE) |
|
|
@ -3851,14 +3852,14 @@ inline void gcode_G28() { |
|
|
|
stepper.synchronize(); |
|
|
|
|
|
|
|
// TODO: clear the leveling matrix or the planner will be set incorrectly
|
|
|
|
run_z_probe(); // clears the ABL non-delta matrix only
|
|
|
|
float measured_z = run_z_probe(); // clears the ABL non-delta matrix only
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPGM("Bed X: "); |
|
|
|
SERIAL_PROTOCOL(current_position[X_AXIS] + X_PROBE_OFFSET_FROM_EXTRUDER + 0.0001); |
|
|
|
SERIAL_PROTOCOLPGM(" Y: "); |
|
|
|
SERIAL_PROTOCOL(current_position[Y_AXIS] + Y_PROBE_OFFSET_FROM_EXTRUDER + 0.0001); |
|
|
|
SERIAL_PROTOCOLPGM(" Z: "); |
|
|
|
SERIAL_PROTOCOL(current_position[Z_AXIS] + 0.0001); |
|
|
|
SERIAL_PROTOCOL(measured_z + 0.0001); |
|
|
|
SERIAL_EOL; |
|
|
|
|
|
|
|
stow_z_probe(); |
|
|
|