Marlin 2.0 for Flying Bear 4S/5
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

72 lines
2.1 KiB

/**
* Marlin 3D Printer Firmware
* Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*
*/
#include "../../inc/MarlinConfig.h"
#if HAS_HEATED_BED
#include "../gcode.h"
#include "../../module/temperature.h"
#include "../../module/motion.h"
#include "../../lcd/ultralcd.h"
#if ENABLED(PRINTJOB_TIMER_AUTOSTART)
#include "../../module/printcounter.h"
#endif
#if ENABLED(PRINTER_EVENT_LEDS)
#include "../../feature/leds/leds.h"
#endif
#include "../../Marlin.h" // for wait_for_heatup and idle()
/**
* M140: Set bed temperature
*/
void GcodeSuite::M140() {
if (DEBUGGING(DRYRUN)) return;
if (parser.seenval('S')) thermalManager.setTargetBed(parser.value_celsius());
}
/**
* M190: Sxxx Wait for bed current temp to reach target temp. Waits only when heating
* Rxxx Wait for bed current temp to reach target temp. Waits when heating and cooling
*/
void GcodeSuite::M190() {
if (DEBUGGING(DRYRUN)) return;
const bool no_wait_for_cooling = parser.seenval('S');
if (no_wait_for_cooling || parser.seenval('R')) {
thermalManager.setTargetBed(parser.value_celsius());
#if ENABLED(PRINTJOB_TIMER_AUTOSTART)
if (parser.value_celsius() > BED_MINTEMP)
print_job_timer.start();
#endif
}
else return;
ui.setstatusPGM(thermalManager.isHeatingBed() ? PSTR(MSG_BED_HEATING) : PSTR(MSG_BED_COOLING));
thermalManager.wait_for_bed(no_wait_for_cooling);
}
#endif // HAS_HEATED_BED