* Marlin 3D Printer Firmware
* Copyright (c) 2020 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (c) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <https://www.gnu.org/licenses/>.
*
*/
#pragma once
#include "../inc/MarlinConfig.h"
enum TempSensorID : uint8_t {
TSI_PROBE,
TSI_BED,
#if ENABLED(USE_TEMP_EXT_COMPENSATION)
TSI_EXT,
#endif
TSI_COUNT
};
typedef struct {
uint8_t measurements; // Max. number of measurements to be stored (35 - 80°C)
celsius_t temp_resolution, // Resolution in °C between measurements
start_temp, // Base measurement; z-offset == 0
end_temp;
} temp_calib_t;
/**
* Probe temperature compensation implementation.
* Z-probes like the P.I.N.D.A V2 allow for compensation of
* measurement errors/shifts due to changed temperature.
*/
// Probe temperature calibration constants
#ifndef PTC_SAMPLE_COUNT
#define PTC_SAMPLE_COUNT 10
#endif
#ifndef PTC_SAMPLE_RES
#define PTC_SAMPLE_RES 5
#endif
#ifndef PTC_SAMPLE_START
#define PTC_SAMPLE_START 30
#endif
#define PTC_SAMPLE_END (PTC_SAMPLE_START + (PTC_SAMPLE_COUNT) * PTC_SAMPLE_RES)
// Bed temperature calibration constants
#ifndef BTC_PROBE_TEMP
#define BTC_PROBE_TEMP 30
#endif
#ifndef BTC_SAMPLE_COUNT
#define BTC_SAMPLE_COUNT 10
#endif
#ifndef BTC_SAMPLE_RES
#define BTC_SAMPLE_RES 5
#endif
#ifndef BTC_SAMPLE_START
#define BTC_SAMPLE_START 60
#endif
#define BTC_SAMPLE_END (BTC_SAMPLE_START + (BTC_SAMPLE_COUNT) * BTC_SAMPLE_RES)
// Extruder temperature calibration constants
#if ENABLED(USE_TEMP_EXT_COMPENSATION)
#ifndef ETC_SAMPLE_COUNT
#define ETC_SAMPLE_COUNT 20
#endif
#ifndef ETC_SAMPLE_RES
#define ETC_SAMPLE_RES 5
#endif
#ifndef ETC_SAMPLE_START
#define ETC_SAMPLE_START 180
#endif
#define ETC_SAMPLE_END (ETC_SAMPLE_START + (ETC_SAMPLE_COUNT) * ETC_SAMPLE_RES)
#endif
#ifndef PTC_PROBE_HEATING_OFFSET
#define PTC_PROBE_HEATING_OFFSET 0.5f
#endif
#ifndef PTC_PROBE_RAISE
#define PTC_PROBE_RAISE 10
#endif
static constexpr temp_calib_t cali_info_init[TSI_COUNT] = {
{ PTC_SAMPLE_COUNT, PTC_SAMPLE_RES, PTC_SAMPLE_START, PTC_SAMPLE_END }, // Probe
{ BTC_SAMPLE_COUNT, BTC_SAMPLE_RES, BTC_SAMPLE_START, BTC_SAMPLE_END }, // Bed
#if ENABLED(USE_TEMP_EXT_COMPENSATION)
{ ETC_SAMPLE_COUNT, ETC_SAMPLE_RES, ETC_SAMPLE_START, ETC_SAMPLE_END }, // Extruder
#endif
};
class ProbeTempComp {
public:
static const temp_calib_t cali_info[TSI_COUNT];
// Where to park nozzle to wait for probe cooldown
static constexpr xyz_pos_t park_point = PTC_PARK_POS;
// XY coordinates of nozzle for probing the bed
static constexpr xy_pos_t measure_point = PTC_PROBE_POS; // Coordinates to probe
//measure_point = { 12.0f, 7.3f }; // Coordinates for the MK52 magnetic heatbed
static constexpr celsius_t probe_calib_bed_temp = BED_MAX_TARGET, // Bed temperature while calibrating probe
bed_calib_probe_temp = BTC_PROBE_TEMP; // Probe temperature while calibrating bed
static int16_t *sensor_z_offsets[TSI_COUNT],
z_offsets_probe[cali_info_init[TSI_PROBE].measurements], // (µm)
z_offsets_bed[cali_info_init[TSI_BED].measurements]; // (µm)
#if ENABLED(USE_TEMP_EXT_COMPENSATION)
static int16_t z_offsets_ext[cali_info_init[TSI_EXT].measurements]; // (µm)
#endif
static inline void reset_index() { calib_idx = 0; };
static inline uint8_t get_index() { return calib_idx; }
static void clear_offsets(const TempSensorID tsi);
static inline void clear_all_offsets() {
clear_offsets(TSI_BED);
clear_offsets(TSI_PROBE);
TERN_(USE_TEMP_EXT_COMPENSATION, clear_offsets(TSI_EXT));
}
static bool set_offset(const TempSensorID tsi, const uint8_t idx, const int16_t offset);
static void print_offsets();
static void prepare_new_calibration(const_float_t init_meas_z);
static void push_back_new_measurement(const TempSensorID tsi, const_float_t meas_z);
static bool finish_calibration(const TempSensorID tsi);
static void compensate_measurement(const TempSensorID tsi, const celsius_t temp, float &meas_z);
private:
static uint8_t calib_idx;
/**
* Base value. Temperature compensation values will be deltas
* to this value, set at first probe.
*/
static float init_measurement;
/**
* Fit a linear function in measured temperature offsets
* to allow generating values of higher temperatures.
*/
static bool linear_regression(const TempSensorID tsi, float &k, float &d);
};
extern ProbeTempComp temp_comp;