Marlin 2.0 for Flying Bear 4S/5
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

72 lines
2.2 KiB

/**
* Marlin 3D Printer Firmware
* Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*
*/
#include "../../inc/MarlinConfig.h"
#if HAS_BED_PROBE
#include "../gcode.h"
#include "../../module/motion.h"
#include "../../module/probe.h"
#include "../../feature/bedlevel/bedlevel.h"
/**
* G30: Do a single Z probe at the current XY
*
* Parameters:
*
* X Probe X position (default current X)
* Y Probe Y position (default current Y)
* E Engage the probe for each probe
*/
void GcodeSuite::G30() {
const float xpos = parser.linearval('X', current_position[X_AXIS] + X_PROBE_OFFSET_FROM_EXTRUDER),
ypos = parser.linearval('Y', current_position[Y_AXIS] + Y_PROBE_OFFSET_FROM_EXTRUDER);
if (!position_is_reachable_by_probe(xpos, ypos)) return;
// Disable leveling so the planner won't mess with us
#if HAS_LEVELING
set_bed_leveling_enabled(false);
#endif
setup_for_endstop_or_probe_move();
const ProbePtRaise raise_after = parser.boolval('E') ? PROBE_PT_STOW : PROBE_PT_NONE;
const float measured_z = probe_pt(xpos, ypos, raise_after, 1);
if (!isnan(measured_z)) {
SERIAL_PROTOCOLPAIR_F("Bed X: ", xpos);
SERIAL_PROTOCOLPAIR_F(" Y: ", ypos);
SERIAL_PROTOCOLLNPAIR_F(" Z: ", measured_z);
}
clean_up_after_endstop_or_probe_move();
#if Z_AFTER_PROBING
if (raise_after == PROBE_PT_STOW) move_z_after_probing();
#endif
report_current_position();
}
#endif // HAS_BED_PROBE