You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
373 lines
13 KiB
373 lines
13 KiB
/**
|
|
* SanityCheck.h
|
|
*
|
|
* Test configuration values for errors at compile-time.
|
|
*/
|
|
#ifndef SANITYCHECK_H
|
|
#define SANITYCHECK_H
|
|
|
|
/**
|
|
* Dual Stepper Drivers
|
|
*/
|
|
#if ENABLED(Z_DUAL_STEPPER_DRIVERS) && ENABLED(Y_DUAL_STEPPER_DRIVERS)
|
|
#error You cannot have dual stepper drivers for both Y and Z.
|
|
#endif
|
|
|
|
/**
|
|
* Progress Bar
|
|
*/
|
|
#if ENABLED(LCD_PROGRESS_BAR)
|
|
#if DISABLED(SDSUPPORT)
|
|
#error LCD_PROGRESS_BAR requires SDSUPPORT.
|
|
#endif
|
|
#if ENABLED(DOGLCD)
|
|
#error LCD_PROGRESS_BAR does not apply to graphical displays.
|
|
#endif
|
|
#if ENABLED(FILAMENT_LCD_DISPLAY)
|
|
#error LCD_PROGRESS_BAR and FILAMENT_LCD_DISPLAY are not fully compatible. Comment out this line to use both.
|
|
#endif
|
|
#endif
|
|
|
|
/**
|
|
* Babystepping
|
|
*/
|
|
#if ENABLED(BABYSTEPPING)
|
|
#if ENABLED(COREXY) && ENABLED(BABYSTEP_XY)
|
|
#error BABYSTEPPING only implemented for Z axis on CoreXY.
|
|
#endif
|
|
#if ENABLED(SCARA)
|
|
#error BABYSTEPPING is not implemented for SCARA yet.
|
|
#endif
|
|
#if ENABLED(DELTA) && ENABLED(BABYSTEP_XY)
|
|
#error BABYSTEPPING only implemented for Z axis on deltabots.
|
|
#endif
|
|
#endif
|
|
|
|
/**
|
|
* Filament Change with Extruder Runout Prevention
|
|
*/
|
|
#if ENABLED(FILAMENTCHANGEENABLE) && ENABLED(EXTRUDER_RUNOUT_PREVENT)
|
|
#error EXTRUDER_RUNOUT_PREVENT currently incompatible with FILAMENTCHANGE.
|
|
#endif
|
|
|
|
/**
|
|
* Options only for EXTRUDERS > 1
|
|
*/
|
|
#if EXTRUDERS > 1
|
|
|
|
#if EXTRUDERS > 4
|
|
#error The maximum number of EXTRUDERS in Marlin is 4.
|
|
#endif
|
|
|
|
#if ENABLED(TEMP_SENSOR_1_AS_REDUNDANT)
|
|
#error EXTRUDERS must be 1 with TEMP_SENSOR_1_AS_REDUNDANT.
|
|
#endif
|
|
|
|
#if ENABLED(HEATERS_PARALLEL)
|
|
#error EXTRUDERS must be 1 with HEATERS_PARALLEL.
|
|
#endif
|
|
|
|
#if ENABLED(Y_DUAL_STEPPER_DRIVERS)
|
|
#error EXTRUDERS must be 1 with Y_DUAL_STEPPER_DRIVERS.
|
|
#endif
|
|
|
|
#if ENABLED(Z_DUAL_STEPPER_DRIVERS)
|
|
#error EXTRUDERS must be 1 with Z_DUAL_STEPPER_DRIVERS.
|
|
#endif
|
|
|
|
#endif // EXTRUDERS > 1
|
|
|
|
/**
|
|
* Limited number of servos
|
|
*/
|
|
#if NUM_SERVOS > 4
|
|
#error The maximum number of SERVOS in Marlin is 4.
|
|
#endif
|
|
#if defined(NUM_SERVOS) && NUM_SERVOS > 0
|
|
#if X_ENDSTOP_SERVO_NR >= 0 || Y_ENDSTOP_SERVO_NR >= 0 || Z_ENDSTOP_SERVO_NR >= 0
|
|
#if X_ENDSTOP_SERVO_NR >= NUM_SERVOS
|
|
#error X_ENDSTOP_SERVO_NR must be smaller than NUM_SERVOS.
|
|
#elif Y_ENDSTOP_SERVO_NR >= NUM_SERVOS
|
|
#error Y_ENDSTOP_SERVO_NR must be smaller than NUM_SERVOS.
|
|
#elif Z_ENDSTOP_SERVO_NR >= NUM_SERVOS
|
|
#error Z_ENDSTOP_SERVO_NR must be smaller than NUM_SERVOS.
|
|
#endif
|
|
#endif
|
|
#endif
|
|
|
|
/**
|
|
* Servo deactivation depends on servo endstops
|
|
*/
|
|
#if ENABLED(DEACTIVATE_SERVOS_AFTER_MOVE) && !HAS_SERVO_ENDSTOPS
|
|
#error At least one of the ?_ENDSTOP_SERVO_NR is required for DEACTIVATE_SERVOS_AFTER_MOVE.
|
|
#endif
|
|
|
|
/**
|
|
* Required LCD language
|
|
*/
|
|
#if DISABLED(DOGLCD) && ENABLED(ULTRA_LCD) && DISABLED(DISPLAY_CHARSET_HD44780_JAPAN) && DISABLED(DISPLAY_CHARSET_HD44780_WESTERN) && DISABLED(DISPLAY_CHARSET_HD44780_CYRILLIC)
|
|
#error You must enable either DISPLAY_CHARSET_HD44780_JAPAN or DISPLAY_CHARSET_HD44780_WESTERN or DISPLAY_CHARSET_HD44780_CYRILLIC for your LCD controller.
|
|
#endif
|
|
|
|
/**
|
|
* Mesh Bed Leveling
|
|
*/
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
#if ENABLED(DELTA)
|
|
#error MESH_BED_LEVELING does not yet support DELTA printers.
|
|
#endif
|
|
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
|
|
#error Select AUTO_BED_LEVELING_FEATURE or MESH_BED_LEVELING, not both.
|
|
#endif
|
|
#if MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
|
|
#error MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS need to be less than 8.
|
|
#endif
|
|
#elif ENABLED(MANUAL_BED_LEVELING)
|
|
#error MESH_BED_LEVELING is required for MANUAL_BED_LEVELING.
|
|
#endif
|
|
|
|
/**
|
|
* Auto Bed Leveling
|
|
*/
|
|
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
|
|
|
|
/**
|
|
* Require a Z min pin
|
|
*/
|
|
#if !PIN_EXISTS(Z_MIN)
|
|
#if !PIN_EXISTS(Z_MIN_PROBE) || (DISABLED(Z_MIN_PROBE_ENDSTOP) || ENABLED(DISABLE_Z_MIN_PROBE_ENDSTOP)) // It's possible for someone to set a pin for the Z probe, but not enable it.
|
|
#if ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST)
|
|
#error You must have a Z_MIN or Z_PROBE endstop to enable Z_MIN_PROBE_REPEATABILITY_TEST.
|
|
#else
|
|
#error AUTO_BED_LEVELING_FEATURE requires a Z_MIN or Z_PROBE endstop. Z_MIN_PIN or Z_MIN_PROBE_PIN must point to a valid hardware pin.
|
|
#endif
|
|
#endif
|
|
#endif
|
|
|
|
/**
|
|
* Require a Z probe pin if Z_MIN_PROBE_ENDSTOP is enabled.
|
|
*/
|
|
#if ENABLED(Z_MIN_PROBE_ENDSTOP)
|
|
#if !PIN_EXISTS(Z_MIN_PROBE)
|
|
#error You must have a Z_MIN_PROBE_PIN defined in your pins_XXXX.h file if you enable Z_MIN_PROBE_ENDSTOP.
|
|
#endif
|
|
// Forcing Servo definitions can break some hall effect sensor setups. Leaving these here for further comment.
|
|
//#ifndef NUM_SERVOS
|
|
// #error You must have NUM_SERVOS defined and there must be at least 1 configured to use Z_MIN_PROBE_ENDSTOP.
|
|
//#endif
|
|
//#if defined(NUM_SERVOS) && NUM_SERVOS < 1
|
|
// #error You must have at least 1 servo defined for NUM_SERVOS to use Z_MIN_PROBE_ENDSTOP.
|
|
//#endif
|
|
//#if Z_ENDSTOP_SERVO_NR < 0
|
|
// #error You must have Z_ENDSTOP_SERVO_NR set to at least 0 or above to use Z_MIN_PROBE_ENDSTOP.
|
|
//#endif
|
|
//#ifndef SERVO_ENDSTOP_ANGLES
|
|
// #error You must have SERVO_ENDSTOP_ANGLES defined for Z Extend and Retract to use Z_MIN_PROBE_ENDSTOP.
|
|
//#endif
|
|
#endif
|
|
/**
|
|
* Check if Probe_Offset * Grid Points is greater than Probing Range
|
|
*/
|
|
#if ENABLED(AUTO_BED_LEVELING_GRID)
|
|
#ifndef DELTA_PROBABLE_RADIUS
|
|
// Be sure points are in the right order
|
|
#if LEFT_PROBE_BED_POSITION > RIGHT_PROBE_BED_POSITION
|
|
#error LEFT_PROBE_BED_POSITION must be less than RIGHT_PROBE_BED_POSITION.
|
|
#elif FRONT_PROBE_BED_POSITION > BACK_PROBE_BED_POSITION
|
|
#error FRONT_PROBE_BED_POSITION must be less than BACK_PROBE_BED_POSITION.
|
|
#endif
|
|
// Make sure probing points are reachable
|
|
#if LEFT_PROBE_BED_POSITION < MIN_PROBE_X
|
|
#error "The given LEFT_PROBE_BED_POSITION can't be reached by the Z probe."
|
|
#elif RIGHT_PROBE_BED_POSITION > MAX_PROBE_X
|
|
#error "The given RIGHT_PROBE_BED_POSITION can't be reached by the Z probe."
|
|
#elif FRONT_PROBE_BED_POSITION < MIN_PROBE_Y
|
|
#error "The given FRONT_PROBE_BED_POSITION can't be reached by the Z probe."
|
|
#elif BACK_PROBE_BED_POSITION > MAX_PROBE_Y
|
|
#error "The given BACK_PROBE_BED_POSITION can't be reached by the Z probe."
|
|
#endif
|
|
#endif
|
|
#else // !AUTO_BED_LEVELING_GRID
|
|
|
|
// Check the triangulation points
|
|
#if ABL_PROBE_PT_1_X < MIN_PROBE_X || ABL_PROBE_PT_1_X > MAX_PROBE_X
|
|
#error "The given ABL_PROBE_PT_1_X can't be reached by the Z probe."
|
|
#elif ABL_PROBE_PT_2_X < MIN_PROBE_X || ABL_PROBE_PT_2_X > MAX_PROBE_X
|
|
#error "The given ABL_PROBE_PT_2_X can't be reached by the Z probe."
|
|
#elif ABL_PROBE_PT_3_X < MIN_PROBE_X || ABL_PROBE_PT_3_X > MAX_PROBE_X
|
|
#error "The given ABL_PROBE_PT_3_X can't be reached by the Z probe."
|
|
#elif ABL_PROBE_PT_1_Y < MIN_PROBE_Y || ABL_PROBE_PT_1_Y > MAX_PROBE_Y
|
|
#error "The given ABL_PROBE_PT_1_Y can't be reached by the Z probe."
|
|
#elif ABL_PROBE_PT_2_Y < MIN_PROBE_Y || ABL_PROBE_PT_2_Y > MAX_PROBE_Y
|
|
#error "The given ABL_PROBE_PT_2_Y can't be reached by the Z probe."
|
|
#elif ABL_PROBE_PT_3_Y < MIN_PROBE_Y || ABL_PROBE_PT_3_Y > MAX_PROBE_Y
|
|
#error "The given ABL_PROBE_PT_3_Y can't be reached by the Z probe."
|
|
#endif
|
|
|
|
#endif // !AUTO_BED_LEVELING_GRID
|
|
|
|
#endif // AUTO_BED_LEVELING_FEATURE
|
|
|
|
/**
|
|
* ULTIPANEL encoder
|
|
*/
|
|
#if ENABLED(ULTIPANEL) && DISABLED(NEWPANEL) && DISABLED(SR_LCD_2W_NL) && !defined(SHIFT_CLK)
|
|
#error ULTIPANEL requires some kind of encoder.
|
|
#endif
|
|
|
|
/**
|
|
* Delta has limited bed leveling options
|
|
*/
|
|
#if ENABLED(DELTA)
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
|
|
|
|
#if DISABLED(AUTO_BED_LEVELING_GRID)
|
|
#error Only AUTO_BED_LEVELING_GRID is supported with DELTA.
|
|
#endif
|
|
|
|
#if ENABLED(Z_PROBE_SLED)
|
|
#error You cannot use Z_PROBE_SLED with DELTA.
|
|
#endif
|
|
|
|
#if ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST)
|
|
#error Z_MIN_PROBE_REPEATABILITY_TEST is not supported with DELTA yet.
|
|
#endif
|
|
|
|
#endif
|
|
|
|
#endif
|
|
|
|
/**
|
|
* Allen Key Z probe requires Auto Bed Leveling grid and Delta
|
|
*/
|
|
#if ENABLED(Z_PROBE_ALLEN_KEY) && !(ENABLED(AUTO_BED_LEVELING_GRID) && ENABLED(DELTA))
|
|
#error Invalid use of Z_PROBE_ALLEN_KEY.
|
|
#endif
|
|
|
|
/**
|
|
* Dual X Carriage requirements
|
|
*/
|
|
#if ENABLED(DUAL_X_CARRIAGE)
|
|
#if EXTRUDERS == 1 || ENABLED(COREXY) \
|
|
|| !HAS_X2_ENABLE || !HAS_X2_STEP || !HAS_X2_DIR \
|
|
|| !defined(X2_HOME_POS) || !defined(X2_MIN_POS) || !defined(X2_MAX_POS) \
|
|
|| !HAS_X_MAX
|
|
#error Missing or invalid definitions for DUAL_X_CARRIAGE mode.
|
|
#endif
|
|
#if X_HOME_DIR != -1 || X2_HOME_DIR != 1
|
|
#error Please use canonical x-carriage assignment.
|
|
#endif
|
|
#endif // DUAL_X_CARRIAGE
|
|
|
|
/**
|
|
* Make sure auto fan pins don't conflict with the fan pin
|
|
*/
|
|
#if HAS_AUTO_FAN && HAS_FAN
|
|
#if EXTRUDER_0_AUTO_FAN_PIN == FAN_PIN
|
|
#error You cannot set EXTRUDER_0_AUTO_FAN_PIN equal to FAN_PIN.
|
|
#elif EXTRUDER_1_AUTO_FAN_PIN == FAN_PIN
|
|
#error You cannot set EXTRUDER_1_AUTO_FAN_PIN equal to FAN_PIN.
|
|
#elif EXTRUDER_2_AUTO_FAN_PIN == FAN_PIN
|
|
#error You cannot set EXTRUDER_2_AUTO_FAN_PIN equal to FAN_PIN.
|
|
#elif EXTRUDER_3_AUTO_FAN_PIN == FAN_PIN
|
|
#error You cannot set EXTRUDER_3_AUTO_FAN_PIN equal to FAN_PIN.
|
|
#endif
|
|
#endif
|
|
|
|
#if HAS_FAN && CONTROLLERFAN_PIN == FAN_PIN
|
|
#error You cannot set CONTROLLERFAN_PIN equal to FAN_PIN.
|
|
#endif
|
|
|
|
/**
|
|
* Test Heater, Temp Sensor, and Extruder Pins; Sensor Type must also be set.
|
|
*/
|
|
#if EXTRUDERS > 3
|
|
#if !HAS_HEATER_3
|
|
#error HEATER_3_PIN not defined for this board.
|
|
#elif !PIN_EXISTS(TEMP_3)
|
|
#error TEMP_3_PIN not defined for this board.
|
|
#elif !PIN_EXISTS(E3_STEP) || !PIN_EXISTS(E3_DIR) || !PIN_EXISTS(E3_ENABLE)
|
|
#error E3_STEP_PIN, E3_DIR_PIN, or E3_ENABLE_PIN not defined for this board.
|
|
#elif TEMP_SENSOR_3 == 0
|
|
#error TEMP_SENSOR_3 is required with 4 EXTRUDERS.
|
|
#endif
|
|
#elif EXTRUDERS > 2
|
|
#if !HAS_HEATER_2
|
|
#error HEATER_2_PIN not defined for this board.
|
|
#elif !PIN_EXISTS(TEMP_2)
|
|
#error TEMP_2_PIN not defined for this board.
|
|
#elif !PIN_EXISTS(E2_STEP) || !PIN_EXISTS(E2_DIR) || !PIN_EXISTS(E2_ENABLE)
|
|
#error E2_STEP_PIN, E2_DIR_PIN, or E2_ENABLE_PIN not defined for this board.
|
|
#elif TEMP_SENSOR_2 == 0
|
|
#error TEMP_SENSOR_2 is required with 3 or more EXTRUDERS.
|
|
#endif
|
|
#elif EXTRUDERS > 1
|
|
#if !PIN_EXISTS(TEMP_1)
|
|
#error TEMP_1_PIN not defined for this board.
|
|
#elif !PIN_EXISTS(E1_STEP) || !PIN_EXISTS(E1_DIR) || !PIN_EXISTS(E1_ENABLE)
|
|
#error E1_STEP_PIN, E1_DIR_PIN, or E1_ENABLE_PIN not defined for this board.
|
|
#endif
|
|
#endif
|
|
|
|
#if EXTRUDERS > 1 || ENABLED(HEATERS_PARALLEL)
|
|
#if !HAS_HEATER_1
|
|
#error HEATER_1_PIN not defined for this board.
|
|
#endif
|
|
#endif
|
|
|
|
#if TEMP_SENSOR_1 == 0
|
|
#if EXTRUDERS > 1
|
|
#error TEMP_SENSOR_1 is required with 2 or more EXTRUDERS.
|
|
#elif ENABLED(TEMP_SENSOR_1_AS_REDUNDANT)
|
|
#error TEMP_SENSOR_1 is required with TEMP_SENSOR_1_AS_REDUNDANT.
|
|
#endif
|
|
#endif
|
|
|
|
#if !HAS_HEATER_0
|
|
#error HEATER_0_PIN not defined for this board.
|
|
#elif !PIN_EXISTS(TEMP_0)
|
|
#error TEMP_0_PIN not defined for this board.
|
|
#elif !PIN_EXISTS(E0_STEP) || !PIN_EXISTS(E0_DIR) || !PIN_EXISTS(E0_ENABLE)
|
|
#error E0_STEP_PIN, E0_DIR_PIN, or E0_ENABLE_PIN not defined for this board.
|
|
#elif TEMP_SENSOR_0 == 0
|
|
#error TEMP_SENSOR_0 is required.
|
|
#endif
|
|
|
|
/**
|
|
* Warnings for old configurations
|
|
*/
|
|
#if WATCH_TEMP_PERIOD > 500
|
|
#error WATCH_TEMP_PERIOD now uses seconds instead of milliseconds.
|
|
#elif DISABLED(THERMAL_PROTECTION_HOTENDS) && (defined(WATCH_TEMP_PERIOD) || defined(THERMAL_PROTECTION_PERIOD))
|
|
#error Thermal Runaway Protection for hotends is now enabled with THERMAL_PROTECTION_HOTENDS.
|
|
#elif DISABLED(THERMAL_PROTECTION_BED) && defined(THERMAL_PROTECTION_BED_PERIOD)
|
|
#error Thermal Runaway Protection for the bed is now enabled with THERMAL_PROTECTION_BED.
|
|
#elif ENABLED(COREXZ) && ENABLED(Z_LATE_ENABLE)
|
|
#error "Z_LATE_ENABLE can't be used with COREXZ."
|
|
#elif defined(X_HOME_RETRACT_MM)
|
|
#error [XYZ]_HOME_RETRACT_MM settings have been renamed [XYZ]_HOME_BUMP_MM.
|
|
#elif defined(PROBE_SERVO_DEACTIVATION_DELAY)
|
|
#error PROBE_SERVO_DEACTIVATION_DELAY has been replaced with DEACTIVATE_SERVOS_AFTER_MOVE and SERVO_DEACTIVATION_DELAY.
|
|
#elif defined(BEEPER)
|
|
#error BEEPER is now BEEPER_PIN. Please update your pins definitions.
|
|
#elif defined(SDCARDDETECT)
|
|
#error SDCARDDETECT is now SD_DETECT_PIN. Please update your pins definitions.
|
|
#elif defined(SDCARDDETECTINVERTED)
|
|
#error SDCARDDETECTINVERTED is now SD_DETECT_INVERTED. Please update your configuration.
|
|
#elif defined(BTENABLED)
|
|
#error BTENABLED is now BLUETOOTH. Please update your configuration.
|
|
#elif defined(CUSTOM_MENDEL_NAME)
|
|
#error CUSTOM_MENDEL_NAME is now CUSTOM_MACHINE_NAME. Please update your configuration.
|
|
#elif defined(HAS_AUTOMATIC_VERSIONING)
|
|
#error HAS_AUTOMATIC_VERSIONING deprecated - use USE_AUTOMATIC_VERSIONING instead
|
|
#elif defined(ENABLE_AUTO_BED_LEVELING)
|
|
#error ENABLE_AUTO_BED_LEVELING deprecated - use AUTO_BED_LEVELING_FEATURE instead
|
|
#elif defined(SDSLOW)
|
|
#error SDSLOW deprecated - set SPI_SPEED to SPI_HALF_SPEED instead
|
|
#elif defined(SDEXTRASLOW)
|
|
#error SDEXTRASLOW deprecated - set SPI_SPEED to SPI_QUARTER_SPEED instead
|
|
#endif
|
|
|
|
#endif //SANITYCHECK_H
|
|
|