Scott Lahteine
460f73056b
Fix ECHOPAIR ambiguity
- Also patch up some warnings
10 years ago
Scott Lahteine
19d418cd6a
Fix up the code to eliminate warnings
10 years ago
Scott Lahteine
b2496533c6
Put " M" into pmem
10 years ago
Scott Lahteine
267d6bef15
Eliminate most warnings
- Fix a bug reading `code_value` for `M503 Sn`
- Hide and remove unused variables
10 years ago
Scott Lahteine
b76a352d41
Fix the planeNormal calculation
10 years ago
Scott Lahteine
410f64782a
Always 4 temp sensors
10 years ago
Scott Lahteine
0b32431551
Remove abs() from planeNormal.z
10 years ago
Scott Lahteine
53169d96e8
Set temp_meas_ready in set_current_temp_raw
10 years ago
Scott Lahteine
04328d7537
Add zprobe_zoffset in set_bed_level_equation_*
- Also a small tweak to SanityCheck.h
10 years ago
Scott Lahteine
78090275a9
Fix probe range editing
- Increase the probe offset range to -20…20
- Apply the range limits to the menu item
10 years ago
AnHardt
1ff6df8f9e
Avoid warnings in SanitiCheck.h
/SanityCheck.h:107:53: warning: missing terminating ' character
...
10 years ago
AnHardt
ebe5b87c2c
< like in the oher compareble loops
to avoid:
Marlin_main.cpp:1790: warning: array subscript is above array bounds.
10 years ago
Christian Bohn
eab5fad539
code formatting
10 years ago
Scott Lahteine
abadeac08d
Group zprobe_zoffset with bed leveling
10 years ago
Scott Lahteine
32331faee4
Prettify Bed Level Correction Matrix
- Put + in front of positive values in the output
10 years ago
Scott Lahteine
5261d35737
Fix custom m-code behavior
Don’t set CUSTOM_M_CODE_SET_Z_PROBE_OFFSET if there’s no Z probe
10 years ago
Scott Lahteine
96b5da7198
Fix up bed leveling code
- Init `zprobe_zoffset`
- Remove `current_position[Z_AXIS] = zprobe_zoffset` lines from the
`set_bed_level_equation_*` functions
- Apply standards to `mesh_bed_leveling` files
- Document `MESH_BED_LEVELING`
10 years ago
AnHardt
f680e509c4
Enclosed error-messages for TEMP_SENSOR_1_AS_REDUNDANT in PSTR()
10 years ago
Victor Torre
d43d47da14
Clean "fromsd" array is not SDSUPPORT
if not have SDSUPPORT the fromsd array is not necessary
10 years ago
AnHardt
ac81b4084f
Make variables and function static.
10 years ago
alexborro
55025558dc
Implement Dry-Run mode in G29
It just probe all the bed without appliying the matrix.
Useful after a first G29 to check the topology.
10 years ago
wurstnase
a4ad9117dd
comment #define Z_DUAL_STEPPER_DRIVERS
10 years ago
chris-bo
2dfd0e5ce7
Update Configuration.h
documentation how to disable buzzer feedback
10 years ago
Christian Bohn
4c3cbc0961
use only one implementation for beeper feedback
10 years ago
AnHardt
01cc97a3c3
Corected condition for PIDdT
10 years ago
AnHardt
94330705c7
Move definition of PIDdT back to temperature.h
make it unconditional
remove all definitions in the 'Configuration.h's
remove form 'Conditionals.h'
10 years ago
AnHardt
dd0067afa6
Fix MAX6675 again and introduce set_current_temp_raw()
to make the temperature-code work again with Arduino 1.0.6.
Sorry could not make an extra block on base level.
10 years ago
AnHardt
8848b7e9ef
Add the missed {} to END_MENU in ultralcd.cpp
what caused an extra update of encoderLine most of the time.
10 years ago
AnHardt
4beffbca69
Make SMALL_INFOFONT configurable.
Tweak the documentation
10 years ago
alexborro
c2ba5d0c09
Fix ZigZag and Topograph table
ZigZag: Inverted Behavior.. If T supplied, it does not zigzag.
Topograph table: The table was rotated 90º clockwise.
10 years ago
alexborro
0ce3576685
New Feature: Z_DUAL_ENDSTOPS
Z_DUAL_ENDSTOPS is a feature to enable the use of 2 endstops for both Z
steppers - Let's call them Z stepper and Z2 stepper.
That way the machine is capable to align the bed during home, since both
Z steppers are homed.
There is also an implementation of M666 (software endstops adjustment)
to this feature.
After Z homing, this adjustment is applied to just one of the steppers
in order to align the bed.
One just need to home the Z axis and measure the distance difference
between both Z axis and apply the math: Z adjust = Z - Z2.
If the Z stepper axis is closer to the bed, the measure Z > Z2 (yes, it
is.. think about it) and the Z adjust would be positive.
Play a little bit with small adjustments (0.5mm) and check the
behaviour.
The M119 (endstops report) will start reporting the Z2 Endstop as well.
10 years ago
AnHardt
c686069ccd
Revert "Remove 6x9 font"
This reverts commit e6cb8ee188
.
Conflicts:
Marlin/dogm_lcd_implementation.h
Confilkt solved
Needs rework.
10 years ago
AnHardt
b00a531df8
Revert "Removed now unneded FONT_STATUSMENU"
This reverts commit 8c5bb38748
.
10 years ago
Scott Lahteine
fc53e43de6
Don't test raw temp for MAX6675
- Remove test of raw temp for thermistor 0 when using MAX6675
- Longer `raw_temp_value` array for `TEMP_SENSOR_1_AS_REDUNDANT`
10 years ago
Scott Lahteine
1fac388664
Revert measurement loop
10 years ago
nicolas-rambaud
37cde8a191
Report changes from previous PR from old code base including :
I've updated the minimum values from the LCD.
It has been a while that i want to at least fix this.
I have an inductive probe and often i need to set my zOffset to something lower than 0.5.
With the current implementation, the default LCD value is set to 0.5 for some reason.
On my case i need to be able to set it down to 0.0 as my inductive probe can be lower than 0.5.
Before with the LCD we couldn't change this value below 0.5. We had to flash the firmware every time which was painful.
Now we are able to change this value down to 0.0 if needed.
I've also changed the minimum value for Z min acceleration.
In the default configuration it's set to 25 but on the LCD the minimum was 100 which is not coherent.
I've changes the minimum to 10. On this axis, depending on the mechanics/motor drivers we might require very low acceleration, so i guess 10 is somehow realistic.
10 years ago
wurstnase
e6f6c6e3a1
fix bad insertion config again
10 years ago
Scott Lahteine
6bdee87be3
Cleanup temperature code
- Get rid of unused temp states in the ISR, resulting in more frequent
temperature reading with fewer sensors
- Shrink code slightly in min/max testing
10 years ago
Scott Lahteine
7717e1ce33
Fix bad insert in configuration
10 years ago
Scott Lahteine
146501215f
Fix mangled probe_pt calls
- Address issue #1669
- Remove the TOPO_ORIGIN configuration setting
10 years ago
maverikou
15345cc249
Corrected Z_PROBE_ALLEN_KEY behaviour.
10 years ago
maverikou
0f034dd97e
Clean up Z_RAISE_AFTER_PROBING to work the same in all code paths except Z_PROBE_SLED.
10 years ago
maverikou
6c96f32069
Blind fix for #1507
10 years ago
Josef Larsson
379348487e
Removed malplaced comment.
10 years ago
Scott Lahteine
582cd780cd
Fix compile error with `*_DUAL_STEPPER_DRIVERS`
- Patch up macros in stepper.cpp
10 years ago
Josef Larsson
9b3462f73f
Refactor SCARA calibration. Save some lines of code and possibly ROM.
10 years ago
Scott Lahteine
691e753cc3
Don't add home offsets in G29
- Address #1262 by leaving values as set
- Rename `add_homing` to `home_offset`
10 years ago
Scott Lahteine
19df90622b
Include Conditionals.h file in update
10 years ago
Scott Lahteine
2c9bd15625
Move LCD items to `Conditionals.h`
- `Conditionals.h` is included twice, setting LCD values the first time
10 years ago
Scott Lahteine
3703694e30
Fix temperature min/max test
- Base tests on all thermistors/thermocouples, not just heater 0