void manage_inactivity(bool ignore_stepper_queue=false)
standard is false so it is not necessary to change additional code. this
change should be better, hopefully nophead like this :)
- Fixed issue when BAL area probing is shorter than it should be for
grid probing
- Warning when BAL activated with Delta Kinematics
- Fix XY_TRAVEL_SPEED when homing Z axis
Current defaults are all 255. If it makes sense to reduce them, they should come down together, and
be in a PID_INTEGRAL_DRIVE_MAX <= PID_MAX <- BANG_MAX relationship.
Moved PSTR() macro to correct place which was causing the " initializer fails to determine size of '__c' " when attempting to compile with BABYSTEPPING enabled.
in
G0 to G3 were previously acknowledged in the get_command method, causing
them to be possibly acknowledged before commands coming after them that
were acknowledged in process_commands.
This patch fixes this, moving the acknowledgement of G0 to G3 to the
process_commands method as well. These commands are therefore no
longer acknowledged when the enter the cmd_buffer but instead only
acknowledged when the enter the plan_buffer.
Guaranteeing that commands are acknowledged in the same order in which
they were received by the firmware allows host software to be able to
track the life cycle of commands and such a better management of the
firmware's serial buffers as well as better internal command processing
and response parsing without having to depend on throwing an epic
amount of regular expressions against each line received back from the
firmware.
FixesErikZalm/Marlin#1147