Jonathan Bastien-Filiatrault
e86f2342c0
Separate the maximum integral power for the bed from PID_INTEGRAL_DRIVE_MAX / PID_MAX.
My PID_INTEGRAL_DRIVE_MAX was at 96, which was insufficient for my bed
to reach its intended temperature. The head requires a low maximum power since
I run on 24 volts and it has a somewhat low thermal mass.
10 years ago
AnHardt
f0523b5816
Initialize the display earlier
to have it ready to display errors during (temperature)-setup.
10 years ago
Scott Lahteine
790c697c19
Fix DEGREES macro
10 years ago
Scott Lahteine
03d5709b09
M110 is a known command
- The command parser now displays “unknown command” in more cases.
Known commands must be added to the `switch` inside `process_commands`
to suppress the error.
10 years ago
Scott Lahteine
d76a01194d
Slight size reduction by adding idle()
10 years ago
Richard Wackerbarth
2deb5a8ac5
Temporary Hack
REVERT THIS CHANGE
In proper use, we want to force the vendor to update this file to reflect distribution parameters
However, until most users have converted to automatic versioning,
we “grant them a pass”
10 years ago
Richard Wackerbarth
b5743d6927
Use SOURCE_CODE_URL rather than FIRMWARE_URL
10 years ago
Richard Wackerbarth
5ea139fd79
Revised Versioning mechanism
10 years ago
AnHardt
da246f5cb1
Activate BED_MINTEMP error.
And call _temp_error() directly for ERR_MAXTEMP_BED to avoid the only one time use of bed_max_temp_error().
Includes #2156 .
10 years ago
AnHardt
959da98d8e
Call kill() only once when triggered by a temperature error
to avoid stack overflow when called from interrupt.
Some clean up for calls of disable_all_heaters().
'disable_all_heaters()' is called in kill() and again when 'killed' is already set inside _temp_error().
10 years ago
Scott Lahteine
68f6f149d0
Reduce code size with out_of_range_error function
- Affects code size when automatic bed leveling is enabled
10 years ago
wurstnase
94120740d8
faster compare
!(~(ab)&0x3) and ab == 0x3 are equal
10 years ago
Scott Lahteine
b55f8718c3
Indent G90/G91, G92
10 years ago
Scott Lahteine
b0d520b109
Indent G30, G31/G32
10 years ago
Scott Lahteine
ffe27a6225
Indent G29
10 years ago
Scott Lahteine
86083badc2
Indent G4, G10/G11, G28
10 years ago
Scott Lahteine
47d7a9cb5e
Indent G2/G3
10 years ago
Scott Lahteine
350f239d84
Indent G0/G1
10 years ago
Scott Lahteine
672b0c1fd3
Cleanup pins in RAMPS_13_EFB boards
10 years ago
Scott Lahteine
15a2351675
No need for +1 on initial seen_pointer
10 years ago
Scott Lahteine
550dd87b2a
Set seen_pointer before calling code_value
10 years ago
Scott Lahteine
063881b5bd
Fix a couple of doubled semicolons
10 years ago
AnHardt
0c0ace2a04
Remove start_watching_heater() fom M104 and M109
10 years ago
Scott Lahteine
00716d0ca0
Small start_watching_heater adjustment
10 years ago
Scott Lahteine
bde9c70d42
Suppress the line mismatch error after M303
10 years ago
wurstnase
ff98b8632b
new endstop bits
10 years ago
AnHardt
9b0fa9c309
Changed dependency of start_watching_heater() in setTargetHotend() to THERMAL_PROTECTION_HOTENDS
10 years ago
AnHardt
bc0764894a
Shift call of start_watching_heater() into setTargetHotend()
to warrant watching is set or reset.
Make setTargetBed() in _lcd_preheat() dependant of TEMP_SENSOR_BED.
Use disable_all_heaters() in lcd_cooldown() and abort_on_endstop_hit.
10 years ago
Richard Wackerbarth
b878bc5620
Introducing the Kossel Pro Build Configuration
10 years ago
Richard Wackerbarth
1d8f61ca8a
AT90USB is defined in pins.h
10 years ago
Richard Wackerbarth
735bf2d35f
Describe Custom M Code
10 years ago
Scott Lahteine
f39658c822
M120 and M121 are reversed
10 years ago
Scott Lahteine
6eb4f90ce7
Also synchronize configurator copies of configs
10 years ago
Scott Lahteine
9d1961ebe3
Witbox and Hephestos are just RAMPS_13_EFB
10 years ago
AnHardt
89d2ee6f13
Make output on display dependant of ULTRA_LCD
10 years ago
AnHardt
cb6e82dc60
Change from kill() to kill(const char *)
in temperature.cpp
10 years ago
AnHardt
9d13942278
Use new kill() with parameter.
10 years ago
AnHardt
f4a93ed997
Add a string parameter to kill()
Makes the output on the LCD adjustable.
10 years ago
AnHardt
2990c6c45f
Use new kill_() for _temp_error()
instead of stop(). We really want to require a reset and no chance to set a new temperature.
10 years ago
Ed Boston
082ed3beed
Propagate Configuration.h changes
Updated all the example Configuration.h files for the new display type.
10 years ago
Ed Boston
152b681bb5
Added link to controller github
Added the link to the github information about the
ELB_FULL_GRAPHIC_CONTROLLER
10 years ago
AnHardt
4d4fa3607b
Remove Duemilanove
No way to fit Marlin into 32K.
10 years ago
Ed Boston
ca8d1756d5
Define fixes
Fixed a couple defines that were not changed or commented out.
10 years ago
CONSULitAS
b96b28b7cc
language.h: update documentation for LANGUAGE_INCLUDE
language.h: update documentation for LANGUAGE_INCLUDE
@thinkyhead What do you think? I think there should be a warning like
this.
10 years ago
Christian Bohn
258bcdefe0
move dogm font selection to configuration_adv.h
10 years ago
AnHardt
7750180c93
transpire -> expire
Minor wording correction.
10 years ago
AnHardt
70163dafb9
Use _temp_error() for all errors thrown by different mechanisms
Now ending in an endless loop.
Tidy up the output format.
We now get:
ERRORTEXT ", system stopped! Heater_ID: " HEATERID
Where ERRORTEXT can be:
"Heating failed"
"Thermal Runaway"
"MAXTEMP triggered"
"MINTEMP triggered"
and soon
"Thermal Jump"
HEATERID can be
0, 1, 2 ,3 , "bed"
This messages are always followed by the common:
"Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
10 years ago
Scott Lahteine
a0f362c735
Simplify & optimize with current_command_args
10 years ago
Scott Lahteine
adc8fcb77f
More parser comments, optimize code_seen, save with goto
10 years ago
Scott Lahteine
c6d8dd19d9
use fetched value
10 years ago