With these changes the output of `M503 S0` is all you need to restore
the EEPROM. Building on this it is straightforward to save and restore
the EEPROM state using the SD card or external GCode file.
- Added `M145` to set “heatup states” for the LCD menu
- Added `M420` to toggle Mesh Bed Leveling
- Added `M421` to set a single Mesh coordinate
- Extended `Config_PrintSettings` with added M codes
- Cleaned up some comments here and there
Centralised beep code to lcd_buzz().
From gcode_M300() and lcd_quick_feedback().
Enforced max. duration for M300 to 5 seconds.
Corrected description in 'Configuration.h'
LCD_FEEDBACK_FREQUENCY_HZ 0 gives now a silent delay of
LCD_FEEDBACK_FREQUENCY_DURATION_MS.
- MENU_ITEM causes lcd_quick_feedback to be called, so only those calls
to `lcd_goto_menu` outside of the `MENU_ITEM` macro need to set the
`feedback` flag when calling `lcd_goto_menu`.
Because we now can use utf8 with up to 3 bytes per symbol,
lcd_status_message[] must be 3*LCD_WIDTH wide.
Filling up the message, or cutting to length, are fixed to.
Fix for #1832 about at the end.
In 'if (encoderPastThreshold || LCD_CLICKED)' lcdDrawUpdate was not set.
'lcd_status_update_delay'-loop was not effective in function
lcd_status_screen().
The loop prevented the update of the status screen but not the displays
update.
Shifted the loop into lcd_update().
- Some messages should not expire with `PROGRESS_MSG_EXPIRE`.
- Simplify conditional for progress bar with sanity checks.
- Rename `messageTick` to `expireStatusMillis` and make it the expire
time.
I've updated the minimum values from the LCD.
It has been a while that i want to at least fix this.
I have an inductive probe and often i need to set my zOffset to something lower than 0.5.
With the current implementation, the default LCD value is set to 0.5 for some reason.
On my case i need to be able to set it down to 0.0 as my inductive probe can be lower than 0.5.
Before with the LCD we couldn't change this value below 0.5. We had to flash the firmware every time which was painful.
Now we are able to change this value down to 0.0 if needed.
I've also changed the minimum value for Z min acceleration.
In the default configuration it's set to 25 but on the LCD the minimum was 100 which is not coherent.
I've changes the minimum to 10. On this axis, depending on the mechanics/motor drivers we might require very low acceleration, so i guess 10 is somehow realistic.