This addresses comments in #1956 and #1079. In particular, this is useful
when both endstops are stationary on a CoreXY system, and the Y axis needs
to be homed before the X so the flags are aligned.
With these changes the output of `M503 S0` is all you need to restore
the EEPROM. Building on this it is straightforward to save and restore
the EEPROM state using the SD card or external GCode file.
- Added `M145` to set “heatup states” for the LCD menu
- Added `M420` to toggle Mesh Bed Leveling
- Added `M421` to set a single Mesh coordinate
- Extended `Config_PrintSettings` with added M codes
- Cleaned up some comments here and there
Centralised beep code to lcd_buzz().
From gcode_M300() and lcd_quick_feedback().
Enforced max. duration for M300 to 5 seconds.
Corrected description in 'Configuration.h'
LCD_FEEDBACK_FREQUENCY_HZ 0 gives now a silent delay of
LCD_FEEDBACK_FREQUENCY_DURATION_MS.
Example Configuration for K8200 : comments/URL/readme
example_configurations\K8200\Configuration.h:
* add machine specific header
* change STRING_URL to K8200 fork (@thinkyhead: What do you think?)
example_configurations\K8200\readme.md:
* updated documentation
* added URLs and links
Example Configuration for K8200 : comments/URL/readme
example_configurations\K8200\Configuration.h:
* add machine specific header
* change STRING_URL to K8200 fork (@thinkyhead: What do you think?)
example_configurations\K8200\readme.md:
* updated documentation
* added URLs and links
The line const bool Z_PROBE_ENDSTOP_INVERTING = false; // set to true to
invert the logic of the endstop is in the main configuration.h but
wasn't present in the example configuration.h's. Causes a compiling
error with Z Probe enabled. Just added it to all the configs. :)
- Add `Conditionals.h` with calculated configuration values
- Add `SanityCheck.h` with checks for configuration errors
- Remove equivalent code from all configurations
- Move error checks from some sources to `SanityCheck.h` also
- Fix initialization of count_direction in stepper.cpp