- enquecommand with multiple lines "\n" doesn't work -> M140 S0 didn't
get processed. So I wrote a new func for the cooldown which uses
setTargetHotend. In addition this does return to status page after
selection.
- Added setWatch() to preheat-functions (Temperatur sanity check
would never have worked when preheating from the lcd panel)
Add new 'callback' edit-menu types that call a function after the edit is done. Use this to display and edit Ki and Kd correctly (removing the scaling first and reapplying it after). Also use it to reset maximum stepwise acceleration rates, after updating mm/s^2 rates via menus. (Previously, changes did nothing to affect planner unless saved back to EEPROM, and the machine reset).
Add calls to updatePID() so that PID loop uses updated values whether set by gcode (it already did this), or by restoring defaults, or loading from EEPROM (it didn't do those last two). Similarly, update the maximum step/s^2 accel rates when the mm/s^2 values are changed - whether by menu edits, restore defaults, or EEPROM read.
Refactor the acceleration rate update logic, and the PID scaling logic, into new functions that can be called from wherever, including the callbacks.
Add menu items to allow the z jerk and e jerk to be viewed/edited in the Control->Motion menu, as per xy jerk.
Conflicts:
Marlin/language.h
The new version of the library means that PANELOLU no longer needs to be
defined in LiquidTWI.h (the library file can be used as is) and the new
version of the library also enables the buzzer on the Panucatt VIKI
panel.
This allows PID_FUNCTIONAL_RANGE to use a maximum duty cycle higher
than PID_MAX. This is useful for powerful heaters to heat quickly in
bang-bang mode, but use a lower duty cycle that is easier to stabilize
in PID mode.