Browse Source

🐛 Fix delta calibrate manual move scale (#22430)

vanilla_fb_2.0.x
InsanityAutomation 3 years ago
committed by Scott Lahteine
parent
commit
f9809ca75a
  1. 3
      Marlin/src/lcd/menu/menu_delta_calibrate.cpp

3
Marlin/src/lcd/menu/menu_delta_calibrate.cpp

@ -31,6 +31,7 @@
#include "menu_item.h" #include "menu_item.h"
#include "../../module/delta.h" #include "../../module/delta.h"
#include "../../module/motion.h" #include "../../module/motion.h"
#include "../../module/planner.h"
#if HAS_LEVELING #if HAS_LEVELING
#include "../../feature/bedlevel/bedlevel.h" #include "../../feature/bedlevel/bedlevel.h"
@ -46,7 +47,7 @@ void _man_probe_pt(const xy_pos_t &xy) {
do_blocking_move_to_xy_z(xy, Z_CLEARANCE_BETWEEN_PROBES); do_blocking_move_to_xy_z(xy, Z_CLEARANCE_BETWEEN_PROBES);
ui.wait_for_move = false; ui.wait_for_move = false;
ui.synchronize(); ui.synchronize();
ui.manual_move.menu_scale = _MAX(PROBE_MANUALLY_STEP, MIN_STEPS_PER_SEGMENT / float(DEFAULT_XYZ_STEPS_PER_UNIT)); ui.manual_move.menu_scale = _MAX(PROBE_MANUALLY_STEP, MIN_STEPS_PER_SEGMENT / planner.settings.axis_steps_per_mm[0]); // Use first axis as for delta XYZ should always match
ui.goto_screen(lcd_move_z); ui.goto_screen(lcd_move_z);
} }
} }

Loading…