Browse Source

Improve Renkforce configs (#16417)

pull/1/head
Dirk O. Kaar 5 years ago
committed by Scott Lahteine
parent
commit
ec03e46ffa
  1. 6
      config/examples/Renkforce/RF100/Configuration.h
  2. 6
      config/examples/Renkforce/RF100XL/Configuration.h
  3. 6
      config/examples/Renkforce/RF100v2/Configuration.h

6
config/examples/Renkforce/RF100/Configuration.h

@ -137,7 +137,7 @@
#define KILL_PIN 64 #define KILL_PIN 64
// Name displayed in the LCD "Ready" message and Info menu // Name displayed in the LCD "Ready" message and Info menu
//#define CUSTOM_MACHINE_NAME "RF100" #define CUSTOM_MACHINE_NAME "RF100"
// Printer's unique ID, used by some programs to differentiate between machines. // Printer's unique ID, used by some programs to differentiate between machines.
// Choose your own or use a service like http://www.uuidgenerator.net/version4 // Choose your own or use a service like http://www.uuidgenerator.net/version4
@ -726,7 +726,7 @@
* Override with M92 * Override with M92
* X, Y, Z, E0 [, E1[, E2...]] * X, Y, Z, E0 [, E1[, E2...]]
*/ */
#define DEFAULT_AXIS_STEPS_PER_UNIT { 78.82, 78.82, 800, 115 } #define DEFAULT_AXIS_STEPS_PER_UNIT { 78.82, 78.82, 800, 116 }
/** /**
* Default Max Feed Rate (mm/s) * Default Max Feed Rate (mm/s)
@ -1055,7 +1055,7 @@
//#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off. //#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off.
//#define Z_HOMING_HEIGHT 4 // (mm) Minimal Z height before homing (G28) for Z clearance above the bed, clamps, ... #define Z_HOMING_HEIGHT 4 // (mm) Minimal Z height before homing (G28) for Z clearance above the bed, clamps, ...
// Be sure you have this distance over your Z_MAX_POS in case. // Be sure you have this distance over your Z_MAX_POS in case.
// Direction of endstops when homing; 1=MAX, -1=MIN // Direction of endstops when homing; 1=MAX, -1=MIN

6
config/examples/Renkforce/RF100XL/Configuration.h

@ -137,7 +137,7 @@
#define KILL_PIN 64 #define KILL_PIN 64
// Name displayed in the LCD "Ready" message and Info menu // Name displayed in the LCD "Ready" message and Info menu
//#define CUSTOM_MACHINE_NAME "RF100" #define CUSTOM_MACHINE_NAME "RF100 XL"
// Printer's unique ID, used by some programs to differentiate between machines. // Printer's unique ID, used by some programs to differentiate between machines.
// Choose your own or use a service like http://www.uuidgenerator.net/version4 // Choose your own or use a service like http://www.uuidgenerator.net/version4
@ -726,7 +726,7 @@
* Override with M92 * Override with M92
* X, Y, Z, E0 [, E1[, E2...]] * X, Y, Z, E0 [, E1[, E2...]]
*/ */
#define DEFAULT_AXIS_STEPS_PER_UNIT { 78.82, 78.82, 800, 115 } #define DEFAULT_AXIS_STEPS_PER_UNIT { 78.82, 78.82, 800, 116 }
/** /**
* Default Max Feed Rate (mm/s) * Default Max Feed Rate (mm/s)
@ -1055,7 +1055,7 @@
//#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off. //#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off.
//#define Z_HOMING_HEIGHT 4 // (mm) Minimal Z height before homing (G28) for Z clearance above the bed, clamps, ... #define Z_HOMING_HEIGHT 4 // (mm) Minimal Z height before homing (G28) for Z clearance above the bed, clamps, ...
// Be sure you have this distance over your Z_MAX_POS in case. // Be sure you have this distance over your Z_MAX_POS in case.
// Direction of endstops when homing; 1=MAX, -1=MIN // Direction of endstops when homing; 1=MAX, -1=MIN

6
config/examples/Renkforce/RF100v2/Configuration.h

@ -137,7 +137,7 @@
#define KILL_PIN 64 #define KILL_PIN 64
// Name displayed in the LCD "Ready" message and Info menu // Name displayed in the LCD "Ready" message and Info menu
//#define CUSTOM_MACHINE_NAME "RF100" #define CUSTOM_MACHINE_NAME "RF100"
// Printer's unique ID, used by some programs to differentiate between machines. // Printer's unique ID, used by some programs to differentiate between machines.
// Choose your own or use a service like http://www.uuidgenerator.net/version4 // Choose your own or use a service like http://www.uuidgenerator.net/version4
@ -726,7 +726,7 @@
* Override with M92 * Override with M92
* X, Y, Z, E0 [, E1[, E2...]] * X, Y, Z, E0 [, E1[, E2...]]
*/ */
#define DEFAULT_AXIS_STEPS_PER_UNIT { 78.82, 78.82, 800, 115 } #define DEFAULT_AXIS_STEPS_PER_UNIT { 78.82, 78.82, 800, 116 }
/** /**
* Default Max Feed Rate (mm/s) * Default Max Feed Rate (mm/s)
@ -1055,7 +1055,7 @@
//#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off. //#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off.
//#define Z_HOMING_HEIGHT 4 // (mm) Minimal Z height before homing (G28) for Z clearance above the bed, clamps, ... #define Z_HOMING_HEIGHT 4 // (mm) Minimal Z height before homing (G28) for Z clearance above the bed, clamps, ...
// Be sure you have this distance over your Z_MAX_POS in case. // Be sure you have this distance over your Z_MAX_POS in case.
// Direction of endstops when homing; 1=MAX, -1=MIN // Direction of endstops when homing; 1=MAX, -1=MIN

Loading…