From e282d69f63b3ea4625a7041946d5e5e95e42c97e Mon Sep 17 00:00:00 2001 From: Petr Zahradnik Date: Sat, 9 Jul 2016 11:38:18 +0200 Subject: [PATCH] Print job timer comment changed --- Marlin/Configuration.h | 5 ++++- Marlin/example_configurations/Cartesio/Configuration.h | 5 ++++- Marlin/example_configurations/Felix/Configuration.h | 5 ++++- Marlin/example_configurations/Hephestos/Configuration.h | 5 ++++- Marlin/example_configurations/Hephestos_2/Configuration.h | 5 ++++- Marlin/example_configurations/K8200/Configuration.h | 5 ++++- Marlin/example_configurations/K8400/Configuration.h | 5 ++++- .../RepRapWorld/Megatronics/Configuration.h | 5 ++++- Marlin/example_configurations/RigidBot/Configuration.h | 5 ++++- Marlin/example_configurations/SCARA/Configuration.h | 5 ++++- Marlin/example_configurations/TAZ4/Configuration.h | 5 ++++- Marlin/example_configurations/WITBOX/Configuration.h | 5 ++++- .../example_configurations/adafruit/ST7565/Configuration.h | 5 ++++- Marlin/example_configurations/delta/biv2.5/Configuration.h | 5 ++++- Marlin/example_configurations/delta/generic/Configuration.h | 5 ++++- .../example_configurations/delta/kossel_mini/Configuration.h | 5 ++++- .../example_configurations/delta/kossel_pro/Configuration.h | 5 ++++- .../example_configurations/delta/kossel_xl/Configuration.h | 5 ++++- Marlin/example_configurations/makibox/Configuration.h | 5 ++++- Marlin/example_configurations/tvrrug/Round2/Configuration.h | 5 ++++- 20 files changed, 80 insertions(+), 20 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index aa1733cc26..947c9245ea 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -790,7 +790,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/Cartesio/Configuration.h b/Marlin/example_configurations/Cartesio/Configuration.h index 2fd390eed2..1a78e0b5d4 100644 --- a/Marlin/example_configurations/Cartesio/Configuration.h +++ b/Marlin/example_configurations/Cartesio/Configuration.h @@ -789,7 +789,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/Felix/Configuration.h b/Marlin/example_configurations/Felix/Configuration.h index d8495eb840..b6d798cb44 100644 --- a/Marlin/example_configurations/Felix/Configuration.h +++ b/Marlin/example_configurations/Felix/Configuration.h @@ -773,7 +773,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/Hephestos/Configuration.h b/Marlin/example_configurations/Hephestos/Configuration.h index a047e59c55..0e9bf234af 100644 --- a/Marlin/example_configurations/Hephestos/Configuration.h +++ b/Marlin/example_configurations/Hephestos/Configuration.h @@ -782,7 +782,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/Hephestos_2/Configuration.h b/Marlin/example_configurations/Hephestos_2/Configuration.h index 4704fa8227..c4bd607791 100644 --- a/Marlin/example_configurations/Hephestos_2/Configuration.h +++ b/Marlin/example_configurations/Hephestos_2/Configuration.h @@ -784,7 +784,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/K8200/Configuration.h b/Marlin/example_configurations/K8200/Configuration.h index 5267edcbd2..ddf6f7d6c6 100644 --- a/Marlin/example_configurations/K8200/Configuration.h +++ b/Marlin/example_configurations/K8200/Configuration.h @@ -807,7 +807,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/K8400/Configuration.h b/Marlin/example_configurations/K8400/Configuration.h index a7c61de56b..550f9bd3ea 100644 --- a/Marlin/example_configurations/K8400/Configuration.h +++ b/Marlin/example_configurations/K8400/Configuration.h @@ -790,7 +790,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h b/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h index e394b6b2af..3de1f0540b 100644 --- a/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h +++ b/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h @@ -790,7 +790,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/RigidBot/Configuration.h b/Marlin/example_configurations/RigidBot/Configuration.h index ad5c408500..367cfcb48a 100644 --- a/Marlin/example_configurations/RigidBot/Configuration.h +++ b/Marlin/example_configurations/RigidBot/Configuration.h @@ -788,7 +788,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/SCARA/Configuration.h b/Marlin/example_configurations/SCARA/Configuration.h index 1c23794d01..c63171354f 100644 --- a/Marlin/example_configurations/SCARA/Configuration.h +++ b/Marlin/example_configurations/SCARA/Configuration.h @@ -798,7 +798,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/TAZ4/Configuration.h b/Marlin/example_configurations/TAZ4/Configuration.h index e5a7dd8443..7c50aa0f3b 100644 --- a/Marlin/example_configurations/TAZ4/Configuration.h +++ b/Marlin/example_configurations/TAZ4/Configuration.h @@ -811,7 +811,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/WITBOX/Configuration.h b/Marlin/example_configurations/WITBOX/Configuration.h index d3012dbfb1..0b9a6a80d5 100644 --- a/Marlin/example_configurations/WITBOX/Configuration.h +++ b/Marlin/example_configurations/WITBOX/Configuration.h @@ -782,7 +782,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/adafruit/ST7565/Configuration.h b/Marlin/example_configurations/adafruit/ST7565/Configuration.h index 9c4f23d181..c7592bc8d8 100644 --- a/Marlin/example_configurations/adafruit/ST7565/Configuration.h +++ b/Marlin/example_configurations/adafruit/ST7565/Configuration.h @@ -790,7 +790,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/delta/biv2.5/Configuration.h b/Marlin/example_configurations/delta/biv2.5/Configuration.h index 3dfd2dd93f..aca2d8b498 100644 --- a/Marlin/example_configurations/delta/biv2.5/Configuration.h +++ b/Marlin/example_configurations/delta/biv2.5/Configuration.h @@ -885,7 +885,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/delta/generic/Configuration.h b/Marlin/example_configurations/delta/generic/Configuration.h index 396a406710..38798fc9a5 100644 --- a/Marlin/example_configurations/delta/generic/Configuration.h +++ b/Marlin/example_configurations/delta/generic/Configuration.h @@ -879,7 +879,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/delta/kossel_mini/Configuration.h b/Marlin/example_configurations/delta/kossel_mini/Configuration.h index 53f0310b0b..fef003f0af 100644 --- a/Marlin/example_configurations/delta/kossel_mini/Configuration.h +++ b/Marlin/example_configurations/delta/kossel_mini/Configuration.h @@ -882,7 +882,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/delta/kossel_pro/Configuration.h b/Marlin/example_configurations/delta/kossel_pro/Configuration.h index ec37272def..f8685d5f32 100644 --- a/Marlin/example_configurations/delta/kossel_pro/Configuration.h +++ b/Marlin/example_configurations/delta/kossel_pro/Configuration.h @@ -882,7 +882,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/delta/kossel_xl/Configuration.h b/Marlin/example_configurations/delta/kossel_xl/Configuration.h index 1d17d17f1f..2dc46f30c9 100644 --- a/Marlin/example_configurations/delta/kossel_xl/Configuration.h +++ b/Marlin/example_configurations/delta/kossel_xl/Configuration.h @@ -884,7 +884,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/makibox/Configuration.h b/Marlin/example_configurations/makibox/Configuration.h index 6543925582..0b33f909b1 100644 --- a/Marlin/example_configurations/makibox/Configuration.h +++ b/Marlin/example_configurations/makibox/Configuration.h @@ -793,7 +793,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: diff --git a/Marlin/example_configurations/tvrrug/Round2/Configuration.h b/Marlin/example_configurations/tvrrug/Round2/Configuration.h index 8d14edadfb..2771c366e6 100644 --- a/Marlin/example_configurations/tvrrug/Round2/Configuration.h +++ b/Marlin/example_configurations/tvrrug/Round2/Configuration.h @@ -784,7 +784,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo // Print job timer // // Enable this option to automatically start and stop the -// print job timer when M104 and M109 commands are received. +// print job timer when M104/M109/M190 commands are received. +// M104 (extruder without wait) - high temp = none, low temp = stop timer +// M109 (extruder with wait) - high temp = start timer, low temp = stop timer +// M190 (bed with wait) - high temp = start timer, low temp = none // // In all cases the timer can be started and stopped using // the following commands: