Browse Source

Consolidate 3-point leveling point options

pull/1/head
Scott Lahteine 7 years ago
parent
commit
dd2949922b
  1. 40
      Marlin/Configuration.h
  2. 40
      Marlin/src/config/default/Configuration.h
  3. 40
      Marlin/src/config/examples/AlephObjects/TAZ4/Configuration.h
  4. 40
      Marlin/src/config/examples/AliExpress/CL-260/Configuration.h
  5. 44
      Marlin/src/config/examples/Anet/A6/Configuration.h
  6. 44
      Marlin/src/config/examples/Anet/A8/Configuration.h
  7. 40
      Marlin/src/config/examples/Azteeg/X5GT/Configuration.h
  8. 44
      Marlin/src/config/examples/BIBO/TouchX/cyclops/Configuration.h
  9. 54
      Marlin/src/config/examples/BIBO/TouchX/default/Configuration.h
  10. 40
      Marlin/src/config/examples/BQ/Hephestos/Configuration.h
  11. 43
      Marlin/src/config/examples/BQ/Hephestos_2/Configuration.h
  12. 40
      Marlin/src/config/examples/BQ/WITBOX/Configuration.h
  13. 40
      Marlin/src/config/examples/Cartesio/Configuration.h
  14. 45
      Marlin/src/config/examples/Creality/CR-10/Configuration.h
  15. 42
      Marlin/src/config/examples/Creality/CR-10S/Configuration.h
  16. 44
      Marlin/src/config/examples/Creality/CR-10mini/Configuration.h
  17. 40
      Marlin/src/config/examples/Creality/Ender-2/Configuration.h
  18. 42
      Marlin/src/config/examples/Creality/Ender-4/Configuration.h
  19. 40
      Marlin/src/config/examples/Felix/Configuration.h
  20. 40
      Marlin/src/config/examples/Felix/DUAL/Configuration.h
  21. 55
      Marlin/src/config/examples/FolgerTech/i3-2020/Configuration.h
  22. 44
      Marlin/src/config/examples/Geeetech/GT2560/Configuration.h
  23. 39
      Marlin/src/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h
  24. 40
      Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h
  25. 40
      Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h
  26. 40
      Marlin/src/config/examples/Infitary/i3-M508/Configuration.h
  27. 42
      Marlin/src/config/examples/JGAurora/A5/Configuration.h
  28. 40
      Marlin/src/config/examples/MakerParts/Configuration.h
  29. 47
      Marlin/src/config/examples/Malyan/M150/Configuration.h
  30. 40
      Marlin/src/config/examples/Malyan/M200/Configuration.h
  31. 40
      Marlin/src/config/examples/Micromake/C1/basic/Configuration.h
  32. 40
      Marlin/src/config/examples/Micromake/C1/enhanced/Configuration.h
  33. 40
      Marlin/src/config/examples/Mks/Sbase/Configuration.h
  34. 40
      Marlin/src/config/examples/RepRapWorld/Megatronics/Configuration.h
  35. 40
      Marlin/src/config/examples/RigidBot/Configuration.h
  36. 40
      Marlin/src/config/examples/SCARA/Configuration.h
  37. 40
      Marlin/src/config/examples/STM32F10/Configuration.h
  38. 40
      Marlin/src/config/examples/Sanguinololu/Configuration.h
  39. 40
      Marlin/src/config/examples/TheBorg/Configuration.h
  40. 44
      Marlin/src/config/examples/TinyBoy2/Configuration.h
  41. 46
      Marlin/src/config/examples/Tronxy/X1/Configuration.h
  42. 40
      Marlin/src/config/examples/Tronxy/X5S/Configuration.h
  43. 48
      Marlin/src/config/examples/Tronxy/XY100/Configuration.h
  44. 40
      Marlin/src/config/examples/UltiMachine/Archim2/Configuration.h
  45. 40
      Marlin/src/config/examples/Velleman/K8200/Configuration.h
  46. 40
      Marlin/src/config/examples/Velleman/K8400/Configuration.h
  47. 40
      Marlin/src/config/examples/Velleman/K8400/Dual-head/Configuration.h
  48. 43
      Marlin/src/config/examples/Wanhao/Duplicator 6/Configuration.h
  49. 40
      Marlin/src/config/examples/adafruit/ST7565/Configuration.h
  50. 48
      Marlin/src/config/examples/delta/FLSUN/auto_calibrate/Configuration.h
  51. 42
      Marlin/src/config/examples/delta/FLSUN/kossel/Configuration.h
  52. 43
      Marlin/src/config/examples/delta/FLSUN/kossel_mini/Configuration.h
  53. 47
      Marlin/src/config/examples/delta/Hatchbox_Alpha/Configuration.h
  54. 46
      Marlin/src/config/examples/delta/generic/Configuration.h
  55. 46
      Marlin/src/config/examples/delta/kossel_mini/Configuration.h
  56. 50
      Marlin/src/config/examples/delta/kossel_pro/Configuration.h
  57. 46
      Marlin/src/config/examples/delta/kossel_xl/Configuration.h
  58. 49
      Marlin/src/config/examples/gCreate/gMax1.5+/Configuration.h
  59. 40
      Marlin/src/config/examples/makibox/Configuration.h
  60. 40
      Marlin/src/config/examples/stm32f103ret6/Configuration.h
  61. 40
      Marlin/src/config/examples/tvrrug/Round2/Configuration.h
  62. 46
      Marlin/src/config/examples/wt150/Configuration.h
  63. 30
      Marlin/src/feature/bedlevel/ubl/ubl_G29.cpp
  64. 6
      Marlin/src/gcode/bedlevel/abl/G29.cpp
  65. 63
      Marlin/src/inc/Conditionals_post.h
  66. 31
      Marlin/src/inc/SanityCheck.h

40
Marlin/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/default/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/AlephObjects/TAZ4/Configuration.h

@ -983,12 +983,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1011,17 +1010,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1034,13 +1022,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1061,6 +1042,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/AliExpress/CL-260/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

44
Marlin/src/config/examples/Anet/A6/Configuration.h

@ -827,7 +827,7 @@
#define Z_CLEARANCE_DEPLOY_PROBE 10 // Z Clearance for Deploy/Stow
#define Z_CLEARANCE_BETWEEN_PROBES 5 // Z Clearance between probe points
//#define Z_AFTER_PROBING 5 // Z position after probing is done
//#define Z_CLEARANCE_DEPLOY_PROBE 5 // Z Clearance for Deploy/Stow
//#define Z_CLEARANCE_DEPLOY_PROBE 5 // Z Clearance for Deploy/Stow
//#define Z_CLEARANCE_BETWEEN_PROBES 3 // Z Clearance between probe points
//#define Z_AFTER_PROBING 3 // Z position after probing is done
@ -1087,10 +1087,10 @@
//#define BACK_PROBE_BED_POSITION 190
// ANET A6 BLTOUCH right (39mm) to the nozzle
#define LEFT_PROBE_BED_POSITION 36
#define RIGHT_PROBE_BED_POSITION 190
#define FRONT_PROBE_BED_POSITION 20
#define BACK_PROBE_BED_POSITION 190
//#define LEFT_PROBE_BED_POSITION 36
//#define RIGHT_PROBE_BED_POSITION 190
//#define FRONT_PROBE_BED_POSITION 20
//#define BACK_PROBE_BED_POSITION 190
// ANET A6 with new X-Axis and modded Y-Axis
//#define LEFT_PROBE_BED_POSITION 20
@ -1104,7 +1104,6 @@
//#define FRONT_PROBE_BED_POSITION 20
//#define BACK_PROBE_BED_POSITION 194
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1126,17 +1125,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1149,13 +1137,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1176,6 +1157,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1687,6 +1681,8 @@
// RepRapDiscount FULL GRAPHIC Smart Controller
// http://reprap.org/wiki/RepRapDiscount_Full_Graphic_Smart_Controller
//
// Note: Details on connecting to the Anet V1.0 controller are in the file pins_ANET_10.h
//
//#define REPRAP_DISCOUNT_FULL_GRAPHIC_SMART_CONTROLLER
//

44
Marlin/src/config/examples/Anet/A8/Configuration.h

@ -970,12 +970,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION 15
//#define RIGHT_PROBE_BED_POSITION 190
//#define FRONT_PROBE_BED_POSITION 15
//#define BACK_PROBE_BED_POSITION 170
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1002,12 +1001,12 @@
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 20
#define ABL_PROBE_PT_1_Y 160
#define ABL_PROBE_PT_2_X 20
#define ABL_PROBE_PT_2_Y 10
#define ABL_PROBE_PT_3_X 180
#define ABL_PROBE_PT_3_Y 10
#define PROBE_PT_1_X 20
#define PROBE_PT_1_Y 160
#define PROBE_PT_2_X 20
#define PROBE_PT_2_Y 10
#define PROBE_PT_3_X 180
#define PROBE_PT_3_Y 10
#elif ENABLED(AUTO_BED_LEVELING_UBL)
@ -1021,13 +1020,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1048,6 +1040,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1541,11 +1546,12 @@
//
//#define G3D_PANEL
//
// RepRapDiscount FULL GRAPHIC Smart Controller
// http://reprap.org/wiki/RepRapDiscount_Full_Graphic_Smart_Controller
//
// Note: Details on connecting to the Anet V1.0 controller are in the file pins_ANET_10.h
//
//#define REPRAP_DISCOUNT_FULL_GRAPHIC_SMART_CONTROLLER
//

40
Marlin/src/config/examples/Azteeg/X5GT/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

44
Marlin/src/config/examples/BIBO/TouchX/cyclops/Configuration.h

@ -810,8 +810,8 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off.
#define Z_HOMING_HEIGHT 10 // (in mm) Minimal z height before homing (G28) for Z clearance above the bed, clamps, ...
// Be sure you have this distance over your Z_MAX_POS in case.
#define Z_HOMING_HEIGHT 8 // (in mm) Minimal z height before homing (G28) for Z clearance above the bed, clamps, ...
// Be sure you have this distance over your Z_MAX_POS in case.
// Direction of endstops when homing; 1=MAX, -1=MIN
// :[-1,1]
@ -963,12 +963,11 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION 170
#define FRONT_PROBE_BED_POSITION 20
#define BACK_PROBE_BED_POSITION 170
//#define LEFT_PROBE_BED_POSITION 15
//#define RIGHT_PROBE_BED_POSITION 170
//#define FRONT_PROBE_BED_POSITION 20
//#define BACK_PROBE_BED_POSITION 170
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

54
Marlin/src/config/examples/BIBO/TouchX/default/Configuration.h

@ -528,13 +528,13 @@
#endif
// Mechanical endstop with COM to ground and NC to Signal uses "false" here (most common setup).
#define X_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Y_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define X_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Y_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the probe.
const bool X_MIN_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
const bool Y_MIN_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
const bool Z_MIN_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
const bool X_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
const bool Y_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
const bool Z_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
// Enable this feature if all enabled endstop pins are interrupt-capable.
// This will remove the need to poll the interrupt pins, saving many CPU cycles.
@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION 170
#define FRONT_PROBE_BED_POSITION 20
#define BACK_PROBE_BED_POSITION 170
//#define LEFT_PROBE_BED_POSITION 15
//#define RIGHT_PROBE_BED_POSITION 170
//#define FRONT_PROBE_BED_POSITION 20
//#define BACK_PROBE_BED_POSITION 170
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/BQ/Hephestos/Configuration.h

@ -951,12 +951,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -979,17 +978,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1002,13 +990,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1029,6 +1010,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

43
Marlin/src/config/examples/BQ/Hephestos_2/Configuration.h

@ -159,7 +159,7 @@
#define EXTRUDERS 1
// Generally expected filament diameter (1.75, 2.85, 3.0, ...). Used for Volumetric, Filament Width Sensor, etc.
#define DEFAULT_NOMINAL_FILAMENT_DIA 3.0
#define DEFAULT_NOMINAL_FILAMENT_DIA 1.75
// For Cyclops or any "multi-extruder" that shares a single nozzle.
//#define SINGLENOZZLE
@ -965,11 +965,10 @@
#define GRID_MAX_POINTS_Y 4
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION X_MIN_POS + (X_PROBE_OFFSET_FROM_EXTRUDER)
#define RIGHT_PROBE_BED_POSITION X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
#define FRONT_PROBE_BED_POSITION Y_MIN_POS + (Y_PROBE_OFFSET_FROM_EXTRUDER)
#define BACK_PROBE_BED_POSITION Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
//#define LEFT_PROBE_BED_POSITION X_MIN_POS + (X_PROBE_OFFSET_FROM_EXTRUDER)
//#define RIGHT_PROBE_BED_POSITION X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
//#define FRONT_PROBE_BED_POSITION Y_MIN_POS + (Y_PROBE_OFFSET_FROM_EXTRUDER)
//#define BACK_PROBE_BED_POSITION Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -996,12 +995,12 @@
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X X_MIN_POS + X_PROBE_OFFSET_FROM_EXTRUDER
#define ABL_PROBE_PT_1_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
#define ABL_PROBE_PT_2_X X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
#define ABL_PROBE_PT_2_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
#define ABL_PROBE_PT_3_X ((X_MIN_POS + X_MAX_POS) / 2)
#define ABL_PROBE_PT_3_Y Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
#define PROBE_PT_1_X X_MIN_POS + X_PROBE_OFFSET_FROM_EXTRUDER
#define PROBE_PT_1_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
#define PROBE_PT_2_X X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
#define PROBE_PT_2_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
#define PROBE_PT_3_X ((X_MIN_POS + X_MAX_POS) / 2)
#define PROBE_PT_3_Y Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
#elif ENABLED(AUTO_BED_LEVELING_UBL)
@ -1015,13 +1014,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1042,6 +1034,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/BQ/WITBOX/Configuration.h

@ -951,12 +951,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -979,17 +978,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1002,13 +990,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1029,6 +1010,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Cartesio/Configuration.h

@ -962,12 +962,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -990,17 +989,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1013,13 +1001,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1040,6 +1021,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

45
Marlin/src/config/examples/Creality/CR-10/Configuration.h

@ -973,12 +973,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1001,17 +1000,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1024,14 +1012,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1052,6 +1032,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1416,13 +1409,13 @@
// This option overrides the default number of encoder pulses needed to
// produce one step. Should be increased for high-resolution encoders.
//
#define ENCODER_PULSES_PER_STEP 4
//#define ENCODER_PULSES_PER_STEP 4
//
// Use this option to override the number of step signals required to
// move between next/prev menu items.
//
#define ENCODER_STEPS_PER_MENU_ITEM 1
//#define ENCODER_STEPS_PER_MENU_ITEM 1
/**
* Encoder Direction Options

42
Marlin/src/config/examples/Creality/CR-10S/Configuration.h

@ -948,7 +948,7 @@
/**
* Enable the G26 Mesh Validation Pattern tool.
*/
#define G26_MESH_VALIDATION
#define G26_MESH_VALIDATION // Enable G26 mesh validation
#if ENABLED(G26_MESH_VALIDATION)
#define MESH_TEST_NOZZLE_SIZE 0.4 // (mm) Diameter of primary nozzle.
#define MESH_TEST_LAYER_HEIGHT 0.2 // (mm) Default layer height for the G26 Mesh Validation Tool.
@ -964,12 +964,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -992,17 +991,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1015,13 +1003,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1042,6 +1023,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

44
Marlin/src/config/examples/Creality/CR-10mini/Configuration.h

@ -982,12 +982,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1010,17 +1009,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1033,13 +1021,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1060,6 +1041,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1424,13 +1418,13 @@
// This option overrides the default number of encoder pulses needed to
// produce one step. Should be increased for high-resolution encoders.
//
#define ENCODER_PULSES_PER_STEP 4
//#define ENCODER_PULSES_PER_STEP 4
//
// Use this option to override the number of step signals required to
// move between next/prev menu items.
//
#define ENCODER_STEPS_PER_MENU_ITEM 1
//#define ENCODER_STEPS_PER_MENU_ITEM 1
/**
* Encoder Direction Options

40
Marlin/src/config/examples/Creality/Ender-2/Configuration.h

@ -967,12 +967,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -995,17 +994,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1018,13 +1006,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1045,6 +1026,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

42
Marlin/src/config/examples/Creality/Ender-4/Configuration.h

@ -957,7 +957,7 @@
/**
* Enable the G26 Mesh Validation Pattern tool.
*/
#define G26_MESH_VALIDATION
#define G26_MESH_VALIDATION // Enable G26 mesh validation
#if ENABLED(G26_MESH_VALIDATION)
#define MESH_TEST_NOZZLE_SIZE 0.4 // (mm) Diameter of primary nozzle.
#define MESH_TEST_LAYER_HEIGHT 0.2 // (mm) Default layer height for the G26 Mesh Validation Tool.
@ -973,12 +973,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1001,17 +1000,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1024,13 +1012,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1051,6 +1032,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Felix/Configuration.h

@ -945,12 +945,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -973,17 +972,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -996,13 +984,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1023,6 +1004,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Felix/DUAL/Configuration.h

@ -945,12 +945,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -973,17 +972,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -996,13 +984,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1023,6 +1004,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

55
Marlin/src/config/examples/FolgerTech/i3-2020/Configuration.h

@ -133,8 +133,7 @@
// The following define selects which electronics board you have.
// Please choose the name from boards.h that matches your setup
#ifndef MOTHERBOARD
//#define MOTHERBOARD BOARD_RAMPS_14_RE_ARM_EFB // For people switching over to the Panucatt Re-ARM board
#define MOTHERBOARD BOARD_RAMPS_14_EFB // For unmodified printers using Atmega-2560 and RAMPS boards.
#define MOTHERBOARD BOARD_RAMPS_14_EFB
#endif
// Optional custom name for your RepStrap or other custom machine
@ -728,10 +727,10 @@
*/
#define X_PROBE_OFFSET_FROM_EXTRUDER 38 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -7 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -10.35 // Z offset: -below +above [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -10.30 // Z offset: -below +above [the nozzle]
// Certain types of probes need to stay away from edges
#define MIN_PROBE_EDGE 10
#define MIN_PROBE_EDGE 0
// X and Y axis travel speed (mm/m) between probes
#define XY_PROBE_SPEED 7500
@ -971,11 +970,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 39
#define RIGHT_PROBE_BED_POSITION 170
#define FRONT_PROBE_BED_POSITION 10
#define BACK_PROBE_BED_POSITION 170
//#define LEFT_PROBE_BED_POSITION (X_MIN_POS + 33)
//#define RIGHT_PROBE_BED_POSITION (X_MAX_POS - 37)
//#define FRONT_PROBE_BED_POSITION (Y_MIN_POS + 7)
//#define BACK_PROBE_BED_POSITION (Y_MAX_POS - 12)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1002,12 +1000,12 @@
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 39
#define ABL_PROBE_PT_1_Y 170
#define ABL_PROBE_PT_2_X 39
#define ABL_PROBE_PT_2_Y 10
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 10
#define PROBE_PT_1_X 39
#define PROBE_PT_1_Y 170
#define PROBE_PT_2_X 39
#define PROBE_PT_2_Y 10
#define PROBE_PT_3_X 170
#define PROBE_PT_3_Y 10
#elif ENABLED(AUTO_BED_LEVELING_UBL)
@ -1021,17 +1019,17 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y 10
#define UBL_PROBE_PT_1_X 45 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 170
#define UBL_PROBE_PT_2_X 45
#define UBL_PROBE_PT_2_Y 25
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 25
#define PROBE_PT_1_X 45 // Probing points for 3-Point leveling of the mesh
#define PROBE_PT_1_Y 170
#define PROBE_PT_2_X 45
#define PROBE_PT_2_Y 25
#define PROBE_PT_3_X 180
#define PROBE_PT_3_Y 25
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
#define UBL_Z_RAISE_WHEN_OFF_MESH 2.5 // When the nozzle is off the mesh, this value is used
#define UBL_Z_RAISE_WHEN_OFF_MESH 2.50// When the nozzle is off the mesh, this value is used
// as the Z-Height correction value.
#elif ENABLED(MESH_BED_LEVELING)
@ -1048,6 +1046,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

44
Marlin/src/config/examples/Geeetech/GT2560/Configuration.h

@ -978,12 +978,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1006,17 +1005,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1029,13 +1017,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1056,6 +1037,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1866,8 +1860,8 @@
*/
#if ENABLED(ULTIMAKERCONTROLLER) || ENABLED(REPRAP_DISCOUNT_SMART_CONTROLLER) || ENABLED(G3D_PANEL) || ENABLED(MKS_MINI_12864)
#define SDSUPPORT // Force SD Card support on for these displays
#elif ENABLED(ULTRA_LCD) && ENABLED(DOGLCD) // No panel, just graphical LCD?
#define LCD_WIDTH_OVERRIDE 20 // Default is 22. For this Geeetech use 20
#else
#define LCD_WIDTH_OVERRIDE 20 // Default is 22. For this Geeetech use 20.
#endif
#endif // CONFIGURATION_H

39
Marlin/src/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h

@ -964,10 +964,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -990,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1013,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1040,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h

@ -979,12 +979,11 @@
#define GRID_MAX_POINTS_X 4
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 10
#define RIGHT_PROBE_BED_POSITION (X_MAX_POS - X_PROBE_OFFSET_FROM_EXTRUDER - 14)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_MAX_POS + Y_PROBE_OFFSET_FROM_EXTRUDER - 25)
//#define LEFT_PROBE_BED_POSITION 10
//#define RIGHT_PROBE_BED_POSITION (X_MAX_POS - X_PROBE_OFFSET_FROM_EXTRUDER - 14)
//#define FRONT_PROBE_BED_POSITION 15
//#define BACK_PROBE_BED_POSITION (Y_MAX_POS + Y_PROBE_OFFSET_FROM_EXTRUDER - 25)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1007,17 +1006,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1030,13 +1018,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1057,6 +1038,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h

@ -978,12 +978,11 @@
#define GRID_MAX_POINTS_X 4
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 10
#define RIGHT_PROBE_BED_POSITION (X_MAX_POS - X_PROBE_OFFSET_FROM_EXTRUDER - 14)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_MAX_POS + Y_PROBE_OFFSET_FROM_EXTRUDER - 25)
//#define LEFT_PROBE_BED_POSITION 10
//#define RIGHT_PROBE_BED_POSITION (X_MAX_POS - X_PROBE_OFFSET_FROM_EXTRUDER - 14)
//#define FRONT_PROBE_BED_POSITION 15
//#define BACK_PROBE_BED_POSITION (Y_MAX_POS + Y_PROBE_OFFSET_FROM_EXTRUDER - 25)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1006,17 +1005,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1029,13 +1017,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1056,6 +1037,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Infitary/i3-M508/Configuration.h

@ -967,12 +967,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -995,17 +994,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1018,13 +1006,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1045,6 +1026,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

42
Marlin/src/config/examples/JGAurora/A5/Configuration.h

@ -959,7 +959,7 @@
/**
* Enable the G26 Mesh Validation Pattern tool.
*/
#define G26_MESH_VALIDATION
#define G26_MESH_VALIDATION // Enable G26 mesh validation
#if ENABLED(G26_MESH_VALIDATION)
#define MESH_TEST_NOZZLE_SIZE 0.4 // (mm) Diameter of primary nozzle.
#define MESH_TEST_LAYER_HEIGHT 0.2 // (mm) Default layer height for the G26 Mesh Validation Tool.
@ -976,11 +976,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION 170
#define FRONT_PROBE_BED_POSITION 20
#define BACK_PROBE_BED_POSITION 170
//#define LEFT_PROBE_BED_POSITION 15
//#define RIGHT_PROBE_BED_POSITION 170
//#define FRONT_PROBE_BED_POSITION 20
//#define BACK_PROBE_BED_POSITION 170
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1003,17 +1002,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1026,13 +1014,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1052,6 +1033,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/MakerParts/Configuration.h

@ -983,12 +983,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1011,17 +1010,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1034,13 +1022,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1061,6 +1042,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

47
Marlin/src/config/examples/Malyan/M150/Configuration.h

@ -21,7 +21,7 @@
*/
/**
* Malyan M150 Configuration
* Maylan M150 Configuration
* Non-Automatic Bed Level config by default
*/
@ -778,8 +778,8 @@
* Example: `M851 Z-5` with a CLEARANCE of 4 => 9mm from bed to nozzle.
* But: `M851 Z+1` with a CLEARANCE of 2 => 2mm from bed to nozzle.
*/
#define Z_CLEARANCE_DEPLOY_PROBE 10 // Z Clearance for Deploy/Stow
#define Z_CLEARANCE_BETWEEN_PROBES 5 // Z Clearance between probe points
//#define Z_CLEARANCE_DEPLOY_PROBE 10 // Z Clearance for Deploy/Stow
//#define Z_CLEARANCE_BETWEEN_PROBES 5 // Z Clearance between probe points
//#define Z_AFTER_PROBING 5 // Z position after probing is done
// For M851 give a range for adjusting the Z probe offset
@ -992,11 +992,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 50
#define RIGHT_PROBE_BED_POSITION 150
#define FRONT_PROBE_BED_POSITION 50
#define BACK_PROBE_BED_POSITION 150
//#define LEFT_PROBE_BED_POSITION 50
//#define RIGHT_PROBE_BED_POSITION 150
//#define FRONT_PROBE_BED_POSITION 50
//#define BACK_PROBE_BED_POSITION 150
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1023,12 +1022,12 @@
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 50
#define ABL_PROBE_PT_1_Y 150
#define ABL_PROBE_PT_2_X 50
#define ABL_PROBE_PT_2_Y 50
#define ABL_PROBE_PT_3_X 150
#define ABL_PROBE_PT_3_Y 50
#define PROBE_PT_1_X 50
#define PROBE_PT_1_Y 150
#define PROBE_PT_2_X 50
#define PROBE_PT_2_Y 50
#define PROBE_PT_3_X 150
#define PROBE_PT_3_Y 50
#elif ENABLED(AUTO_BED_LEVELING_UBL)
@ -1042,13 +1041,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1069,6 +1061,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Malyan/M200/Configuration.h

@ -962,12 +962,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -990,17 +989,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1013,13 +1001,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1040,6 +1021,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Micromake/C1/basic/Configuration.h

@ -967,12 +967,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -995,17 +994,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1018,13 +1006,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1045,6 +1026,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Micromake/C1/enhanced/Configuration.h

@ -967,12 +967,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -995,17 +994,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1018,13 +1006,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1045,6 +1026,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Mks/Sbase/Configuration.h

@ -964,11 +964,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 32
#define RIGHT_PROBE_BED_POSITION 170
#define FRONT_PROBE_BED_POSITION 20
#define BACK_PROBE_BED_POSITION 170
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/RepRapWorld/Megatronics/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/RigidBot/Configuration.h

@ -961,12 +961,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -989,17 +988,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1012,13 +1000,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1039,6 +1020,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/SCARA/Configuration.h

@ -974,12 +974,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1002,17 +1001,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1025,13 +1013,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1052,6 +1033,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/STM32F10/Configuration.h

@ -966,12 +966,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -994,17 +993,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1017,13 +1005,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1044,6 +1025,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Sanguinololu/Configuration.h

@ -994,12 +994,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1022,17 +1021,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1045,13 +1033,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1072,6 +1053,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/TheBorg/Configuration.h

@ -964,11 +964,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 32
#define RIGHT_PROBE_BED_POSITION 210
#define FRONT_PROBE_BED_POSITION 10
#define BACK_PROBE_BED_POSITION 210
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

44
Marlin/src/config/examples/TinyBoy2/Configuration.h

@ -1019,12 +1019,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1047,17 +1046,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1070,13 +1058,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1097,6 +1078,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1461,13 +1455,13 @@
// This option overrides the default number of encoder pulses needed to
// produce one step. Should be increased for high-resolution encoders.
//
#define ENCODER_PULSES_PER_STEP 4
//#define ENCODER_PULSES_PER_STEP 4
//
// Use this option to override the number of step signals required to
// move between next/prev menu items.
//
#define ENCODER_STEPS_PER_MENU_ITEM 1
//#define ENCODER_STEPS_PER_MENU_ITEM 1
/**
* Encoder Direction Options

46
Marlin/src/config/examples/Tronxy/X1/Configuration.h

@ -365,7 +365,7 @@
#define PIDTEMP
#define BANG_MAX 255 // Limits current to nozzle while in bang-bang mode; 255=full current
#define PID_MAX BANG_MAX // Limits current to nozzle while PID is active (see PID_FUNCTIONAL_RANGE below); 255=full current
#define PID_K1 0.95 // Smoothing factor within any PID loop
#define PID_K1 0.95 // Smoothing factor within the PID
#if ENABLED(PIDTEMP)
//#define PID_AUTOTUNE_MENU // Add PID Autotune to the LCD "Temperature" menu to run M303 and apply the result.
//#define PID_DEBUG // Sends debug data to the serial port.
@ -947,7 +947,7 @@
/**
* Enable the G26 Mesh Validation Pattern tool.
*/
#define G26_MESH_VALIDATION
#define G26_MESH_VALIDATION // Enable G26 mesh validation
#if ENABLED(G26_MESH_VALIDATION)
#define MESH_TEST_NOZZLE_SIZE 0.4 // (mm) Diameter of primary nozzle.
#define MESH_TEST_LAYER_HEIGHT 0.2 // (mm) Default layer height for the G26 Mesh Validation Tool.
@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1577,7 +1571,7 @@
//
// ANET and Tronxy Controller supported displays.
//
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
// This LCD is known to be susceptible to electrical interference
// which scrambles the display. Pressing any button clears it up.
// This is a LCD2004 display with 5 analog buttons.

40
Marlin/src/config/examples/Tronxy/X5S/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION 270
#define FRONT_PROBE_BED_POSITION 20
#define BACK_PROBE_BED_POSITION 260
//#define LEFT_PROBE_BED_POSITION 15
//#define RIGHT_PROBE_BED_POSITION 270
//#define FRONT_PROBE_BED_POSITION 20
//#define BACK_PROBE_BED_POSITION 260
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

48
Marlin/src/config/examples/Tronxy/XY100/Configuration.h

@ -974,12 +974,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1002,17 +1001,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1025,13 +1013,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1052,6 +1033,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1588,10 +1582,10 @@
//
// ANET and Tronxy Controller supported displays.
//
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
// This LCD is known to be susceptible to electrical interference
// which scrambles the display. Pressing any button clears it up.
// This is a LCD2004 display with 5 analog buttons.
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
// This LCD is known to be susceptible to electrical interference
// which scrambles the display. Pressing any button clears it up.
// This is a LCD2004 display with 5 analog buttons.
//#define ANET_FULL_GRAPHICS_LCD // Anet 128x64 full graphics lcd with rotary encoder as used on Anet A6
// A clone of the RepRapDiscount full graphics display but with

40
Marlin/src/config/examples/UltiMachine/Archim2/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Velleman/K8200/Configuration.h

@ -993,12 +993,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1021,17 +1020,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1044,13 +1032,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1071,6 +1052,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Velleman/K8400/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/Velleman/K8400/Dual-head/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

43
Marlin/src/config/examples/Wanhao/Duplicator 6/Configuration.h

@ -973,12 +973,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1001,17 +1000,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1024,19 +1012,9 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
//#define UBL_Z_RAISE_WHEN_OFF_MESH 2.5 // When the nozzle is off the mesh, this value is used
// as the Z-Height correction value.
#elif ENABLED(MESH_BED_LEVELING)
//===========================================================================
@ -1051,6 +1029,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/adafruit/ST7565/Configuration.h

@ -963,12 +963,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -991,17 +990,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1014,13 +1002,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1041,6 +1022,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

48
Marlin/src/config/examples/delta/FLSUN/auto_calibrate/Configuration.h

@ -1095,11 +1095,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 15)
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define RIGHT_PROBE_BED_POSITION (DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define BACK_PROBE_BED_POSITION (DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1126,12 +1125,12 @@
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
@ -1145,14 +1144,12 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1174,6 +1171,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

42
Marlin/src/config/examples/delta/FLSUN/kossel/Configuration.h

@ -1095,11 +1095,10 @@
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 15)
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define RIGHT_PROBE_BED_POSITION (DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define BACK_PROBE_BED_POSITION (DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1122,17 +1121,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1145,15 +1133,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1174,6 +1153,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

43
Marlin/src/config/examples/delta/FLSUN/kossel_mini/Configuration.h

@ -1093,13 +1093,11 @@
#define GRID_MAX_POINTS_X 9
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 15)
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define RIGHT_PROBE_BED_POSITION (DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
//#define BACK_PROBE_BED_POSITION (DELTA_PRINTABLE_RADIUS - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1122,17 +1120,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1145,15 +1132,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1174,6 +1152,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

47
Marlin/src/config/examples/delta/Hatchbox_Alpha/Configuration.h

@ -1087,9 +1087,6 @@
#define MESH_TEST_BED_TEMP 60.0 // (°C) Default bed temperature for the G26 Mesh Validation Tool.
#endif
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 10)
#endif
#if ENABLED(AUTO_BED_LEVELING_LINEAR) || ENABLED(AUTO_BED_LEVELING_BILINEAR)
@ -1099,11 +1096,11 @@
#define GRID_MAX_POINTS_X 9
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
// Set the boundaries for probing (where the probe can reach).
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define RIGHT_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define BACK_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1130,12 +1127,12 @@
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X -116
#define ABL_PROBE_PT_1_Y -67.5
#define ABL_PROBE_PT_2_X 116
#define ABL_PROBE_PT_2_Y -67.5
#define ABL_PROBE_PT_3_X 0
#define ABL_PROBE_PT_3_Y 135
#define PROBE_PT_1_X -116
#define PROBE_PT_1_Y -67.5
#define PROBE_PT_2_X 116
#define PROBE_PT_2_Y -67.5
#define PROBE_PT_3_X 0
#define PROBE_PT_3_Y 135
#elif ENABLED(AUTO_BED_LEVELING_UBL)
@ -1149,15 +1146,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1178,6 +1166,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

46
Marlin/src/config/examples/delta/generic/Configuration.h

@ -1072,9 +1072,6 @@
#define MESH_TEST_BED_TEMP 60.0 // (°C) Default bed temperature for the G26 Mesh Validation Tool.
#endif
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 10)
#endif
#if ENABLED(AUTO_BED_LEVELING_LINEAR) || ENABLED(AUTO_BED_LEVELING_BILINEAR)
@ -1084,11 +1081,11 @@
#define GRID_MAX_POINTS_X 9
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
// Set the boundaries for probing (where the probe can reach).
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define RIGHT_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define BACK_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1111,17 +1108,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1134,15 +1120,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1163,6 +1140,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

46
Marlin/src/config/examples/delta/kossel_mini/Configuration.h

@ -1075,9 +1075,6 @@
#define MESH_TEST_BED_TEMP 60.0 // (°C) Default bed temperature for the G26 Mesh Validation Tool.
#endif
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 10)
#endif
#if ENABLED(AUTO_BED_LEVELING_LINEAR) || ENABLED(AUTO_BED_LEVELING_BILINEAR)
@ -1087,11 +1084,11 @@
#define GRID_MAX_POINTS_X 9
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
// Set the boundaries for probing (where the probe can reach).
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define RIGHT_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define BACK_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1114,17 +1111,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1137,15 +1123,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1166,6 +1143,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

50
Marlin/src/config/examples/delta/kossel_pro/Configuration.h

@ -684,7 +684,7 @@
*
* Enable this option for a probe connected to the Z Min endstop pin.
*/
//#define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN
#define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN
/**
* Z_MIN_PROBE_ENDSTOP
@ -705,7 +705,7 @@
* disastrous consequences. Use with caution and do your homework.
*
*/
#define Z_MIN_PROBE_ENDSTOP
//#define Z_MIN_PROBE_ENDSTOP
/**
* Probe Type
@ -1075,9 +1075,6 @@
#define MESH_TEST_BED_TEMP 60.0 // (°C) Default bed temperature for the G26 Mesh Validation Tool.
#endif
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 10)
#endif
#if ENABLED(AUTO_BED_LEVELING_LINEAR) || ENABLED(AUTO_BED_LEVELING_BILINEAR)
@ -1087,11 +1084,11 @@
#define GRID_MAX_POINTS_X 7
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
// Set the boundaries for probing (where the probe can reach).
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define RIGHT_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE))
//#define BACK_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS -(MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1114,17 +1111,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1137,15 +1123,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1166,6 +1143,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

46
Marlin/src/config/examples/delta/kossel_xl/Configuration.h

@ -1084,9 +1084,6 @@
#define MESH_TEST_BED_TEMP 60.0 // (°C) Default bed temperature for the G26 Mesh Validation Tool.
#endif
// Set the boundaries for probing (where the probe can reach).
#define DELTA_PROBEABLE_RADIUS (DELTA_PRINTABLE_RADIUS - 10)
#endif
#if ENABLED(AUTO_BED_LEVELING_LINEAR) || ENABLED(AUTO_BED_LEVELING_BILINEAR)
@ -1096,11 +1093,11 @@
#define GRID_MAX_POINTS_X 5
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define LEFT_PROBE_BED_POSITION -(DELTA_PROBEABLE_RADIUS)
#define RIGHT_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS
#define FRONT_PROBE_BED_POSITION - (DELTA_PROBEABLE_RADIUS - 20)
#define BACK_PROBE_BED_POSITION DELTA_PROBEABLE_RADIUS - 40
// Set the boundaries for probing (where the probe can reach).
//#define LEFT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS + MIN_PROBE_EDGE)
//#define RIGHT_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS - (MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION -(DELTA_PRINTABLE_RADIUS + MIN_PROBE_EDGE)
//#define BACK_PROBE_BED_POSITION DELTA_PRINTABLE_RADIUS - (MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1123,17 +1120,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1146,15 +1132,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define _PX(R,A) (R) * cos(RADIANS(A))
#define _PY(R,A) (R) * sin(RADIANS(A))
#define UBL_PROBE_PT_1_X _PX(DELTA_PROBEABLE_RADIUS, 0) // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y _PY(DELTA_PROBEABLE_RADIUS, 0)
#define UBL_PROBE_PT_2_X _PX(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_2_Y _PY(DELTA_PROBEABLE_RADIUS, 120)
#define UBL_PROBE_PT_3_X _PX(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_PROBE_PT_3_Y _PY(DELTA_PROBEABLE_RADIUS, 240)
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1175,6 +1152,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

49
Marlin/src/config/examples/gCreate/gMax1.5+/Configuration.h

@ -977,12 +977,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -1005,17 +1004,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1028,12 +1016,12 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 53 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 323
#define UBL_PROBE_PT_2_X 53
#define UBL_PROBE_PT_2_Y 63
#define UBL_PROBE_PT_3_X 348
#define UBL_PROBE_PT_3_Y 211
#define PROBE_PT_1_X 53 // Probing points for 3-Point leveling of the mesh
#define PROBE_PT_1_Y 323
#define PROBE_PT_2_X 53
#define PROBE_PT_2_Y 63
#define PROBE_PT_3_X 348
#define PROBE_PT_3_Y 211
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1055,6 +1043,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1099,8 +1100,8 @@
#define Z_SAFE_HOMING
#if ENABLED(Z_SAFE_HOMING)
#define Z_SAFE_HOMING_X_POINT ((X_BED_SIZE) / 2 - 4) // X point for Z homing when homing all axes (G28).
#define Z_SAFE_HOMING_Y_POINT ((Y_BED_SIZE) / 2 + 4) // Y point for Z homing when homing all axes (G28).
#define Z_SAFE_HOMING_X_POINT ((X_BED_SIZE) / 2 - 8) // X point for Z homing when homing all axes (G28).
#define Z_SAFE_HOMING_Y_POINT ((Y_BED_SIZE) / 2 - 4) // Y point for Z homing when homing all axes (G28).
#endif
// Homing speeds (mm/m)

40
Marlin/src/config/examples/makibox/Configuration.h

@ -966,12 +966,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -994,17 +993,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1017,13 +1005,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1044,6 +1025,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/stm32f103ret6/Configuration.h

@ -964,12 +964,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -992,17 +991,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1015,13 +1003,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1042,6 +1023,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

40
Marlin/src/config/examples/tvrrug/Round2/Configuration.h

@ -958,12 +958,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -986,17 +985,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1009,13 +997,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1036,6 +1017,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY

46
Marlin/src/config/examples/wt150/Configuration.h

@ -507,7 +507,7 @@
#define USE_ZMAX_PLUG
// Enable pullup for all endstops to prevent a floating state
#define ENDSTOPPULLUPS
//#define ENDSTOPPULLUPS
#if DISABLED(ENDSTOPPULLUPS)
// Disable ENDSTOPPULLUPS to set pullups individually
//#define ENDSTOPPULLUP_XMAX
@ -968,12 +968,11 @@
#define GRID_MAX_POINTS_X 3
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
// Set the boundaries for probing (where the probe can reach).
#define LEFT_PROBE_BED_POSITION 15
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
#define FRONT_PROBE_BED_POSITION 15
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
// Probe along the Y axis, advancing X after each column
//#define PROBE_Y_FIRST
@ -996,17 +995,6 @@
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// 3 arbitrary points to probe.
// A simple cross-product is used to estimate the plane of the bed.
#define ABL_PROBE_PT_1_X 15
#define ABL_PROBE_PT_1_Y 180
#define ABL_PROBE_PT_2_X 15
#define ABL_PROBE_PT_2_Y 20
#define ABL_PROBE_PT_3_X 170
#define ABL_PROBE_PT_3_Y 20
#elif ENABLED(AUTO_BED_LEVELING_UBL)
//===========================================================================
@ -1019,13 +1007,6 @@
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
#define UBL_PROBE_PT_1_Y 180
#define UBL_PROBE_PT_2_X 39
#define UBL_PROBE_PT_2_Y 20
#define UBL_PROBE_PT_3_X 180
#define UBL_PROBE_PT_3_Y 20
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
@ -1046,6 +1027,19 @@
#endif // BED_LEVELING
/**
* Points to probe for all 3-point Leveling procedures.
* Override if the automatically selected points are inadequate.
*/
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
//#define PROBE_PT_1_X 15
//#define PROBE_PT_1_Y 180
//#define PROBE_PT_2_X 15
//#define PROBE_PT_2_Y 20
//#define PROBE_PT_3_X 170
//#define PROBE_PT_3_Y 20
#endif
/**
* Use the LCD controller for bed leveling
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
@ -1410,13 +1404,13 @@
// This option overrides the default number of encoder pulses needed to
// produce one step. Should be increased for high-resolution encoders.
//
#define ENCODER_PULSES_PER_STEP 4
//#define ENCODER_PULSES_PER_STEP 4
//
// Use this option to override the number of step signals required to
// move between next/prev menu items.
//
#define ENCODER_STEPS_PER_MENU_ITEM 1
//#define ENCODER_STEPS_PER_MENU_ITEM 1
/**
* Encoder Direction Options

30
Marlin/src/feature/bedlevel/ubl/ubl_G29.cpp

@ -1519,46 +1519,46 @@
incremental_LSF_reset(&lsf_results);
if (do_3_pt_leveling) {
measured_z = probe_pt(UBL_PROBE_PT_1_X, UBL_PROBE_PT_1_Y, false, g29_verbose_level);
measured_z = probe_pt(PROBE_PT_1_X, PROBE_PT_1_Y, false, g29_verbose_level);
if (isnan(measured_z))
abort_flag = true;
else {
measured_z -= get_z_correction(UBL_PROBE_PT_1_X, UBL_PROBE_PT_1_Y);
measured_z -= get_z_correction(PROBE_PT_1_X, PROBE_PT_1_Y);
//z1 = measured_z;
if (g29_verbose_level > 3) {
serial_spaces(16);
SERIAL_ECHOLNPAIR("Corrected_Z=", measured_z);
}
incremental_LSF(&lsf_results, UBL_PROBE_PT_1_X, UBL_PROBE_PT_1_Y, measured_z);
incremental_LSF(&lsf_results, PROBE_PT_1_X, PROBE_PT_1_Y, measured_z);
}
if (!abort_flag) {
measured_z = probe_pt(UBL_PROBE_PT_2_X, UBL_PROBE_PT_2_Y, false, g29_verbose_level);
measured_z = probe_pt(PROBE_PT_2_X, PROBE_PT_2_Y, false, g29_verbose_level);
//z2 = measured_z;
if (isnan(measured_z))
abort_flag = true;
else {
measured_z -= get_z_correction(UBL_PROBE_PT_2_X, UBL_PROBE_PT_2_Y);
measured_z -= get_z_correction(PROBE_PT_2_X, PROBE_PT_2_Y);
if (g29_verbose_level > 3) {
serial_spaces(16);
SERIAL_ECHOLNPAIR("Corrected_Z=", measured_z);
}
incremental_LSF(&lsf_results, UBL_PROBE_PT_2_X, UBL_PROBE_PT_2_Y, measured_z);
incremental_LSF(&lsf_results, PROBE_PT_2_X, PROBE_PT_2_Y, measured_z);
}
}
if (!abort_flag) {
measured_z = probe_pt(UBL_PROBE_PT_3_X, UBL_PROBE_PT_3_Y, true, g29_verbose_level);
measured_z = probe_pt(PROBE_PT_3_X, PROBE_PT_3_Y, true, g29_verbose_level);
//z3 = measured_z;
if (isnan(measured_z))
abort_flag = true;
else {
measured_z -= get_z_correction(UBL_PROBE_PT_3_X, UBL_PROBE_PT_3_Y);
measured_z -= get_z_correction(PROBE_PT_3_X, PROBE_PT_3_Y);
if (g29_verbose_level > 3) {
serial_spaces(16);
SERIAL_ECHOLNPAIR("Corrected_Z=", measured_z);
}
incremental_LSF(&lsf_results, UBL_PROBE_PT_3_X, UBL_PROBE_PT_3_Y, measured_z);
incremental_LSF(&lsf_results, PROBE_PT_3_X, PROBE_PT_3_Y, measured_z);
}
}
@ -1705,29 +1705,29 @@
*/
#if 0
float t, t1, d;
t = normal.x * (UBL_PROBE_PT_1_X) + normal.y * (UBL_PROBE_PT_1_Y);
t = normal.x * (PROBE_PT_1_X) + normal.y * (PROBE_PT_1_Y);
d = t + normal.z * z1;
SERIAL_ECHOPGM("D from 1st point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_ECHOPGM(" Z error: ");
SERIAL_ECHO_F(normal.z*z1-get_z_correction(UBL_PROBE_PT_1_X, UBL_PROBE_PT_1_Y), 6);
SERIAL_ECHO_F(normal.z*z1-get_z_correction(PROBE_PT_1_X, PROBE_PT_1_Y), 6);
SERIAL_EOL();
t = normal.x * (UBL_PROBE_PT_2_X) + normal.y * (UBL_PROBE_PT_2_Y);
t = normal.x * (PROBE_PT_2_X) + normal.y * (PROBE_PT_2_Y);
d = t + normal.z * z2;
SERIAL_EOL();
SERIAL_ECHOPGM("D from 2nd point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_ECHOPGM(" Z error: ");
SERIAL_ECHO_F(normal.z*z2-get_z_correction(UBL_PROBE_PT_2_X, UBL_PROBE_PT_2_Y), 6);
SERIAL_ECHO_F(normal.z*z2-get_z_correction(PROBE_PT_2_X, PROBE_PT_2_Y), 6);
SERIAL_EOL();
t = normal.x * (UBL_PROBE_PT_3_X) + normal.y * (UBL_PROBE_PT_3_Y);
t = normal.x * (PROBE_PT_3_X) + normal.y * (PROBE_PT_3_Y);
d = t + normal.z * z3;
SERIAL_ECHOPGM("D from 3rd point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_ECHOPGM(" Z error: ");
SERIAL_ECHO_F(normal.z*z3-get_z_correction(UBL_PROBE_PT_3_X, UBL_PROBE_PT_3_Y), 6);
SERIAL_ECHO_F(normal.z*z3-get_z_correction(PROBE_PT_3_X, PROBE_PT_3_Y), 6);
SERIAL_EOL();
t = normal.x * (Z_SAFE_HOMING_X_POINT) + normal.y * (Z_SAFE_HOMING_Y_POINT);

6
Marlin/src/gcode/bedlevel/abl/G29.cpp

@ -235,9 +235,9 @@ void GcodeSuite::G29() {
// Probe at 3 arbitrary points
ABL_VAR vector_3 points[3] = {
vector_3(ABL_PROBE_PT_1_X, ABL_PROBE_PT_1_Y, 0),
vector_3(ABL_PROBE_PT_2_X, ABL_PROBE_PT_2_Y, 0),
vector_3(ABL_PROBE_PT_3_X, ABL_PROBE_PT_3_Y, 0)
vector_3(PROBE_PT_1_X, PROBE_PT_1_Y, 0),
vector_3(PROBE_PT_2_X, PROBE_PT_2_Y, 0),
vector_3(PROBE_PT_3_X, PROBE_PT_3_Y, 0)
};
#endif // AUTO_BED_LEVELING_3POINT

63
Marlin/src/inc/Conditionals_post.h

@ -1139,6 +1139,69 @@
#endif // MESH_BED_LEVELING || AUTO_BED_LEVELING_UBL
#if ENABLED(AUTO_BED_LEVELING_UBL) || ENABLED(AUTO_BED_LEVELING_3POINT)
#if IS_KINEMATIC
#define SIN0 0.0
#define SIN120 0.866025
#define SIN240 -0.866025
#define COS0 1.0
#define COS120 -0.5
#define COS240 -0.5
#ifndef PROBE_PT_1_X
#define PROBE_PT_1_X (X_CENTER + (_PROBE_RADIUS) * COS0)
#endif
#ifndef PROBE_PT_1_Y
#define PROBE_PT_1_Y (Y_CENTER + (_PROBE_RADIUS) * SIN0)
#endif
#ifndef PROBE_PT_2_X
#define PROBE_PT_2_X (X_CENTER + (_PROBE_RADIUS) * COS120)
#endif
#ifndef PROBE_PT_2_Y
#define PROBE_PT_2_Y (Y_CENTER + (_PROBE_RADIUS) * SIN120)
#endif
#ifndef PROBE_PT_3_X
#define PROBE_PT_3_X (X_CENTER + (_PROBE_RADIUS) * COS240)
#endif
#ifndef PROBE_PT_3_Y
#define PROBE_PT_3_Y (Y_CENTER + (_PROBE_RADIUS) * SIN240)
#endif
#else
#ifndef PROBE_PT_1_X
#define PROBE_PT_1_X MIN_PROBE_X
#endif
#ifndef PROBE_PT_1_Y
#define PROBE_PT_1_Y MIN_PROBE_Y
#endif
#ifndef PROBE_PT_2_X
#define PROBE_PT_2_X MAX_PROBE_X
#endif
#ifndef PROBE_PT_2_Y
#define PROBE_PT_2_Y MIN_PROBE_Y
#endif
#ifndef PROBE_PT_3_X
#define PROBE_PT_3_X X_CENTER
#endif
#ifndef PROBE_PT_3_Y
#define PROBE_PT_3_Y MAX_PROBE_Y
#endif
#endif
#endif
#if ENABLED(AUTO_BED_LEVELING_LINEAR) || ENABLED(AUTO_BED_LEVELING_BILINEAR)
#ifndef LEFT_PROBE_BED_POSITION
#define LEFT_PROBE_BED_POSITION MIN_PROBE_X
#endif
#ifndef RIGHT_PROBE_BED_POSITION
#define RIGHT_PROBE_BED_POSITION MAX_PROBE_X
#endif
#ifndef FRONT_PROBE_BED_POSITION
#define FRONT_PROBE_BED_POSITION MIN_PROBE_Y
#endif
#ifndef BACK_PROBE_BED_POSITION
#define BACK_PROBE_BED_POSITION MAX_PROBE_Y
#endif
#endif
/**
* Buzzer/Speaker
*/

31
Marlin/src/inc/SanityCheck.h

@ -233,6 +233,10 @@
#error "UBL_MESH_INSET is now just MESH_INSET. Please update your configuration."
#elif defined(UBL_MESH_MIN_X) || defined(UBL_MESH_MIN_Y) || defined(UBL_MESH_MAX_X) || defined(UBL_MESH_MAX_Y)
#error "UBL_MESH_(MIN|MAX)_[XY] is now just MESH_(MIN|MAX)_[XY]. Please update your configuration."
#elif defined(ABL_PROBE_PT_1_X) || defined(ABL_PROBE_PT_1_Y) || defined(ABL_PROBE_PT_2_X) || defined(ABL_PROBE_PT_2_Y) || defined(ABL_PROBE_PT_3_X) || defined(ABL_PROBE_PT_3_Y)
#error "ABL_PROBE_PT_[123]_[XY] is now PROBE_PT_[123]_[XY]. Please update your configuration."
#elif defined(UBL_PROBE_PT_1_X) || defined(UBL_PROBE_PT_1_Y) || defined(UBL_PROBE_PT_2_X) || defined(UBL_PROBE_PT_2_Y) || defined(UBL_PROBE_PT_3_X) || defined(UBL_PROBE_PT_3_Y)
#error "UBL_PROBE_PT_[123]_[XY] is now PROBE_PT_[123]_[XY]. Please update your configuration."
#elif defined(ENABLE_MESH_EDIT_GFX_OVERLAY)
#error "ENABLE_MESH_EDIT_GFX_OVERLAY is now MESH_EDIT_GFX_OVERLAY. Please update your configuration."
#elif defined(BABYSTEP_ZPROBE_GFX_REVERSE)
@ -803,6 +807,15 @@ static_assert(X_MAX_LENGTH >= X_BED_SIZE && Y_MAX_LENGTH >= Y_BED_SIZE,
* Bed Leveling Requirements
*/
#if ENABLED(AUTO_BED_LEVELING_UBL) || ENABLED(AUTO_BED_LEVELING_3POINT)
static_assert(WITHIN(PROBE_PT_1_X, MIN_PROBE_X, MAX_PROBE_X), "PROBE_PT_1_X is outside the probe region.");
static_assert(WITHIN(PROBE_PT_2_X, MIN_PROBE_X, MAX_PROBE_X), "PROBE_PT_2_X is outside the probe region.");
static_assert(WITHIN(PROBE_PT_3_X, MIN_PROBE_X, MAX_PROBE_X), "PROBE_PT_3_X is outside the probe region.");
static_assert(WITHIN(PROBE_PT_1_Y, MIN_PROBE_Y, MAX_PROBE_Y), "PROBE_PT_1_Y is outside the probe region.");
static_assert(WITHIN(PROBE_PT_2_Y, MIN_PROBE_Y, MAX_PROBE_Y), "PROBE_PT_2_Y is outside the probe region.");
static_assert(WITHIN(PROBE_PT_3_Y, MIN_PROBE_Y, MAX_PROBE_Y), "PROBE_PT_3_Y is outside the probe region.");
#endif
#if ENABLED(AUTO_BED_LEVELING_UBL)
/**
@ -820,13 +833,6 @@ static_assert(X_MAX_LENGTH >= X_BED_SIZE && Y_MAX_LENGTH >= Y_BED_SIZE,
#error "GRID_MAX_POINTS_[XY] must be a whole number between 3 and 15."
#elif DISABLED(RESTORE_LEVELING_AFTER_G28)
#error "AUTO_BED_LEVELING_UBL (<=1.1.8) always has RESTORE_LEVELING_AFTER_G28 enabled. To keep this behavior, #define RESTORE_LEVELING_AFTER_G28. To keep it disabled comment out this line in SanityCheck.h."
#else
static_assert(WITHIN(UBL_PROBE_PT_1_X, MIN_PROBE_X, MAX_PROBE_X), "UBL_PROBE_PT_1_X is outside the probe region.");
static_assert(WITHIN(UBL_PROBE_PT_2_X, MIN_PROBE_X, MAX_PROBE_X), "UBL_PROBE_PT_2_X is outside the probe region.");
static_assert(WITHIN(UBL_PROBE_PT_3_X, MIN_PROBE_X, MAX_PROBE_X), "UBL_PROBE_PT_3_X is outside the probe region.");
static_assert(WITHIN(UBL_PROBE_PT_1_Y, MIN_PROBE_Y, MAX_PROBE_Y), "UBL_PROBE_PT_1_Y is outside the probe region.");
static_assert(WITHIN(UBL_PROBE_PT_2_Y, MIN_PROBE_Y, MAX_PROBE_Y), "UBL_PROBE_PT_2_Y is outside the probe region.");
static_assert(WITHIN(UBL_PROBE_PT_3_Y, MIN_PROBE_Y, MAX_PROBE_Y), "UBL_PROBE_PT_3_Y is outside the probe region.");
#endif
#elif OLDSCHOOL_ABL
@ -839,7 +845,7 @@ static_assert(X_MAX_LENGTH >= X_BED_SIZE && Y_MAX_LENGTH >= Y_BED_SIZE,
* Delta and SCARA have limited bed leveling options
*/
#if IS_SCARA && DISABLED(AUTO_BED_LEVELING_BILINEAR)
#error "Only AUTO_BED_LEVELING_BILINEAR currently supports SCARA bed leveling."
#error "SCARA machines can only use the AUTO_BED_LEVELING_BILINEAR leveling option."
#endif
/**
@ -854,15 +860,6 @@ static_assert(X_MAX_LENGTH >= X_BED_SIZE && Y_MAX_LENGTH >= Y_BED_SIZE,
static_assert(FRONT_PROBE_BED_POSITION >= MIN_PROBE_Y, "FRONT_PROBE_BED_POSITION is outside the probe region.");
static_assert(BACK_PROBE_BED_POSITION <= MAX_PROBE_Y, "BACK_PROBE_BED_POSITION is outside the probe region.");
#else // AUTO_BED_LEVELING_3POINT
static_assert(WITHIN(ABL_PROBE_PT_1_X, MIN_PROBE_X, MAX_PROBE_X), "ABL_PROBE_PT_1_X is outside the probe region.");
static_assert(WITHIN(ABL_PROBE_PT_2_X, MIN_PROBE_X, MAX_PROBE_X), "ABL_PROBE_PT_2_X is outside the probe region.");
static_assert(WITHIN(ABL_PROBE_PT_3_X, MIN_PROBE_X, MAX_PROBE_X), "ABL_PROBE_PT_3_X is outside the probe region.");
static_assert(WITHIN(ABL_PROBE_PT_1_Y, MIN_PROBE_Y, MAX_PROBE_Y), "ABL_PROBE_PT_1_Y is outside the probe region.");
static_assert(WITHIN(ABL_PROBE_PT_2_Y, MIN_PROBE_Y, MAX_PROBE_Y), "ABL_PROBE_PT_2_Y is outside the probe region.");
static_assert(WITHIN(ABL_PROBE_PT_3_Y, MIN_PROBE_Y, MAX_PROBE_Y), "ABL_PROBE_PT_3_Y is outside the probe region.");
#endif // AUTO_BED_LEVELING_3POINT
#elif ENABLED(MESH_BED_LEVELING)

Loading…
Cancel
Save