@ -50,6 +50,10 @@ |
|
|
|
#define INTERSECTION_CIRCLE_RADIUS 5 |
|
|
|
#define CROSSHAIRS_SIZE 3 |
|
|
|
|
|
|
|
#ifndef G26_XY_FEEDRATE |
|
|
|
#define G26_XY_FEEDRATE (PLANNER_XY_FEEDRATE() / 3.0) |
|
|
|
#endif |
|
|
|
|
|
|
|
#if CROSSHAIRS_SIZE >= INTERSECTION_CIRCLE_RADIUS |
|
|
|
#error "CROSSHAIRS_SIZE must be less than INTERSECTION_CIRCLE_RADIUS." |
|
|
|
#endif |
|
|
@ -240,7 +244,7 @@ void move_to(const float &rx, const float &ry, const float &z, const float &e_de |
|
|
|
|
|
|
|
// Check if X or Y is involved in the movement.
|
|
|
|
// Yes: a 'normal' movement. No: a retract() or recover()
|
|
|
|
feed_value = has_xy_component ? PLANNER_XY_FEEDRATE() / 3.0 : planner.settings.max_feedrate_mm_s[E_AXIS] / 1.5; |
|
|
|
feed_value = has_xy_component ? G26_XY_FEEDRATE : planner.settings.max_feedrate_mm_s[E_AXIS] / 1.5; |
|
|
|
|
|
|
|
if (g26_debug_flag) SERIAL_ECHOLNPAIR("in move_to() feed_value for XY:", feed_value); |
|
|
|
|
|
|
@ -567,8 +571,8 @@ void GcodeSuite::G26() { |
|
|
|
|
|
|
|
if (parser.seenval('B')) { |
|
|
|
g26_bed_temp = parser.value_celsius(); |
|
|
|
if (g26_bed_temp && !WITHIN(g26_bed_temp, 40, 140)) { |
|
|
|
SERIAL_ECHOLNPGM("?Specified bed temperature not plausible (40-140C)."); |
|
|
|
if (g26_bed_temp && !WITHIN(g26_bed_temp, 40, (BED_MAXTEMP - 15))) { |
|
|
|
SERIAL_ECHOLNPAIR("?Specified bed temperature not plausible (40-", int(BED_MAXTEMP - 15), "C)."); |
|
|
|
return; |
|
|
|
} |
|
|
|
} |
|
|
@ -597,7 +601,7 @@ void GcodeSuite::G26() { |
|
|
|
|
|
|
|
if (parser.seenval('S')) { |
|
|
|
g26_nozzle = parser.value_float(); |
|
|
|
if (!WITHIN(g26_nozzle, 0.1, 1.0)) { |
|
|
|
if (!WITHIN(g26_nozzle, 0.1, 2.0)) { |
|
|
|
SERIAL_ECHOLNPGM("?Specified nozzle size not plausible."); |
|
|
|
return; |
|
|
|
} |
|
|
@ -637,7 +641,7 @@ void GcodeSuite::G26() { |
|
|
|
|
|
|
|
if (parser.seenval('H')) { |
|
|
|
g26_hotend_temp = parser.value_celsius(); |
|
|
|
if (!WITHIN(g26_hotend_temp, 165, 280)) { |
|
|
|
if (!WITHIN(g26_hotend_temp, 165, (HEATER_0_MAXTEMP - 15))) { |
|
|
|
SERIAL_ECHOLNPGM("?Specified nozzle temperature not plausible."); |
|
|
|
return; |
|
|
|
} |
|
|
|