Browse Source

Extend Heater Overshoot Options (#21273)

Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
vanilla_fb_2.0.x
Keith Bennett 4 years ago
committed by Scott Lahteine
parent
commit
d4a6014578
  1. 9
      Marlin/Configuration.h

9
Marlin/Configuration.h

@ -476,6 +476,15 @@
#define BED_MAXTEMP 150
#define CHAMBER_MAXTEMP 60
/**
* Thermal Overshoot
* During heatup (and printing) the temperature can often "overshoot" the target by many degrees
* (especially before PID tuning). Setting the target temperature too close to MAXTEMP guarantees
* a MAXTEMP shutdown! Use these values to forbid temperatures being set too close to MAXTEMP.
*/
#define HOTEND_OVERSHOOT 15 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
#define BED_OVERSHOOT 10 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
//===========================================================================