@ -964,24 +964,34 @@ |
|
|
|
//
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Z Probe to nozzle (X,Y) offset, relative to (0, 0). |
|
|
|
* Nozzle-to-Probe offsets { X, Y, Z } |
|
|
|
* |
|
|
|
* In the following example the X and Y offsets are both positive: |
|
|
|
* - Use a caliper or ruler to measure the distance from the tip of |
|
|
|
* the Nozzle to the center-point of the Probe in the X and Y axes. |
|
|
|
* - For the Z offset use your best known value and adjust at runtime. |
|
|
|
* - Probe Offsets can be tuned at runtime with 'M851', LCD menus, babystepping, etc. |
|
|
|
* |
|
|
|
* #define NOZZLE_TO_PROBE_OFFSET { 10, 10, 0 } |
|
|
|
* Assuming the typical work area orientation: |
|
|
|
* - Probe to RIGHT of the Nozzle has a Positive X offset |
|
|
|
* - Probe to LEFT of the Nozzle has a Negative X offset |
|
|
|
* - Probe in BACK of the Nozzle has a Positive Y offset |
|
|
|
* - Probe in FRONT of the Nozzle has a Negative Y offset |
|
|
|
* |
|
|
|
* Some examples: |
|
|
|
* #define NOZZLE_TO_PROBE_OFFSET { 10, 10, -1 } // Example "1"
|
|
|
|
* #define NOZZLE_TO_PROBE_OFFSET {-10, 5, -1 } // Example "2"
|
|
|
|
* #define NOZZLE_TO_PROBE_OFFSET { 5, -5, -1 } // Example "3"
|
|
|
|
* #define NOZZLE_TO_PROBE_OFFSET {-15,-10, -1 } // Example "4"
|
|
|
|
* |
|
|
|
* +-- BACK ---+ |
|
|
|
* | | |
|
|
|
* L | (+) P | R <-- probe (20,20) |
|
|
|
* E | | I |
|
|
|
* F | (-) N (+) | G <-- nozzle (10,10) |
|
|
|
* T | | H |
|
|
|
* | (-) | T |
|
|
|
* | | |
|
|
|
* | [+] | |
|
|
|
* L | 1 | R <-- Example "1" (right+, back+) |
|
|
|
* E | 2 | I <-- Example "2" ( left-, back+) |
|
|
|
* F |[-] N [+]| G <-- Nozzle |
|
|
|
* T | 3 | H <-- Example "3" (right+, front-) |
|
|
|
* | 4 | T <-- Example "4" ( left-, front-) |
|
|
|
* | [-] | |
|
|
|
* O-- FRONT --+ |
|
|
|
* (0,0) |
|
|
|
* |
|
|
|
* Specify a Probe position as { X, Y, Z } |
|
|
|
*/ |
|
|
|
#define NOZZLE_TO_PROBE_OFFSET { 10, 10, 0 } |
|
|
|
|
|
|
|