From 98b55421a524a0ad1e98839e80179452228971b4 Mon Sep 17 00:00:00 2001 From: Scott Lahteine Date: Mon, 11 Mar 2019 16:24:58 -0500 Subject: [PATCH] Clean up some temp config --- Marlin/Configuration.h | 47 +++++++++---------- config/default/Configuration.h | 47 +++++++++---------- .../examples/3DFabXYZ/Migbot/Configuration.h | 47 +++++++++---------- .../AlephObjects/TAZ4/Configuration.h | 47 +++++++++---------- .../AliExpress/CL-260/Configuration.h | 47 +++++++++---------- .../AliExpress/UM2pExt/Configuration.h | 47 +++++++++---------- config/examples/Anet/A2/Configuration.h | 47 +++++++++---------- config/examples/Anet/A2plus/Configuration.h | 47 +++++++++---------- config/examples/Anet/A6/Configuration.h | 47 +++++++++---------- config/examples/Anet/A8/Configuration.h | 47 +++++++++---------- config/examples/AnyCubic/i3/Configuration.h | 47 +++++++++---------- config/examples/ArmEd/Configuration.h | 47 +++++++++---------- config/examples/Azteeg/X5GT/Configuration.h | 47 +++++++++---------- .../BIBO/TouchX/cyclops/Configuration.h | 47 +++++++++---------- .../BIBO/TouchX/default/Configuration.h | 47 +++++++++---------- config/examples/BQ/Hephestos/Configuration.h | 47 +++++++++---------- .../examples/BQ/Hephestos_2/Configuration.h | 45 +++++++++--------- config/examples/BQ/WITBOX/Configuration.h | 47 +++++++++---------- config/examples/Cartesio/Configuration.h | 47 +++++++++---------- .../examples/Creality/CR-10/Configuration.h | 47 +++++++++---------- .../examples/Creality/CR-10S/Configuration.h | 47 +++++++++---------- .../Creality/CR-10_5S/Configuration.h | 47 +++++++++---------- .../Creality/CR-10mini/Configuration.h | 47 +++++++++---------- config/examples/Creality/CR-8/Configuration.h | 47 +++++++++---------- .../examples/Creality/Ender-2/Configuration.h | 47 +++++++++---------- .../examples/Creality/Ender-3/Configuration.h | 47 +++++++++---------- .../examples/Creality/Ender-4/Configuration.h | 47 +++++++++---------- config/examples/Einstart-S/Configuration.h | 47 +++++++++---------- config/examples/Felix/Configuration.h | 47 +++++++++---------- config/examples/Felix/DUAL/Configuration.h | 47 +++++++++---------- .../FlashForge/CreatorPro/Configuration.h | 47 +++++++++---------- .../FolgerTech/i3-2020/Configuration.h | 47 +++++++++---------- .../examples/Formbot/Raptor/Configuration.h | 47 +++++++++---------- .../examples/Formbot/T_Rex_2+/Configuration.h | 47 +++++++++---------- .../examples/Formbot/T_Rex_3/Configuration.h | 47 +++++++++---------- config/examples/Geeetech/A10M/Configuration.h | 47 +++++++++---------- config/examples/Geeetech/A20M/Configuration.h | 47 +++++++++---------- .../examples/Geeetech/GT2560/Configuration.h | 47 +++++++++---------- .../Geeetech/I3_Pro_X-GT2560/Configuration.h | 47 +++++++++---------- .../Geeetech/MeCreator2/Configuration.h | 47 +++++++++---------- .../Prusa i3 Pro B/bltouch/Configuration.h | 47 +++++++++---------- .../Prusa i3 Pro B/noprobe/Configuration.h | 47 +++++++++---------- .../Geeetech/Prusa i3 Pro C/Configuration.h | 47 +++++++++---------- .../Geeetech/Prusa i3 Pro W/Configuration.h | 47 +++++++++---------- .../examples/Infitary/i3-M508/Configuration.h | 47 +++++++++---------- config/examples/JGAurora/A5/Configuration.h | 47 +++++++++---------- config/examples/MakerParts/Configuration.h | 47 +++++++++---------- config/examples/Malyan/M150/Configuration.h | 47 +++++++++---------- config/examples/Malyan/M200/Configuration.h | 47 +++++++++---------- .../Micromake/C1/basic/Configuration.h | 47 +++++++++---------- .../Micromake/C1/enhanced/Configuration.h | 47 +++++++++---------- config/examples/Mks/Robin/Configuration.h | 47 +++++++++---------- config/examples/Mks/Sbase/Configuration.h | 47 +++++++++---------- .../Printrbot/PrintrboardG2/Configuration.h | 47 +++++++++---------- .../examples/RapideLite/RL200/Configuration.h | 47 +++++++++---------- .../examples/RepRapPro/Huxley/Configuration.h | 47 +++++++++---------- .../RepRapWorld/Megatronics/Configuration.h | 47 +++++++++---------- config/examples/RigidBot/Configuration.h | 47 +++++++++---------- config/examples/SCARA/Configuration.h | 47 +++++++++---------- config/examples/STM32F10/Configuration.h | 47 +++++++++---------- config/examples/STM32F4/Configuration.h | 47 +++++++++---------- config/examples/Sanguinololu/Configuration.h | 47 +++++++++---------- config/examples/TheBorg/Configuration.h | 47 +++++++++---------- config/examples/TinyBoy2/Configuration.h | 47 +++++++++---------- config/examples/Tronxy/X1/Configuration.h | 47 +++++++++---------- config/examples/Tronxy/X3A/Configuration.h | 47 +++++++++---------- config/examples/Tronxy/X5S-2E/Configuration.h | 47 +++++++++---------- config/examples/Tronxy/X5S/Configuration.h | 47 +++++++++---------- config/examples/Tronxy/XY100/Configuration.h | 47 +++++++++---------- .../UltiMachine/Archim1/Configuration.h | 47 +++++++++---------- .../UltiMachine/Archim2/Configuration.h | 47 +++++++++---------- config/examples/VORONDesign/Configuration.h | 47 +++++++++---------- .../examples/Velleman/K8200/Configuration.h | 47 +++++++++---------- .../examples/Velleman/K8400/Configuration.h | 47 +++++++++---------- .../Velleman/K8400/Dual-head/Configuration.h | 47 +++++++++---------- .../examples/WASP/PowerWASP/Configuration.h | 47 +++++++++---------- .../Wanhao/Duplicator 6/Configuration.h | 47 +++++++++---------- .../examples/adafruit/ST7565/Configuration.h | 47 +++++++++---------- .../delta/Anycubic/Kossel/Configuration.h | 47 +++++++++---------- .../FLSUN/auto_calibrate/Configuration.h | 47 +++++++++---------- .../delta/FLSUN/kossel/Configuration.h | 47 +++++++++---------- .../delta/FLSUN/kossel_mini/Configuration.h | 47 +++++++++---------- .../Geeetech/Rostock 301/Configuration.h | 47 +++++++++---------- .../delta/Hatchbox_Alpha/Configuration.h | 47 +++++++++---------- .../examples/delta/MKS/SBASE/Configuration.h | 47 +++++++++---------- .../delta/Tevo Little Monster/Configuration.h | 47 +++++++++---------- config/examples/delta/generic/Configuration.h | 47 +++++++++---------- .../delta/kossel_mini/Configuration.h | 47 +++++++++---------- .../examples/delta/kossel_pro/Configuration.h | 47 +++++++++---------- .../examples/delta/kossel_xl/Configuration.h | 47 +++++++++---------- .../examples/gCreate/gMax1.5+/Configuration.h | 47 +++++++++---------- config/examples/makibox/Configuration.h | 47 +++++++++---------- config/examples/stm32f103ret6/Configuration.h | 47 +++++++++---------- config/examples/tvrrug/Round2/Configuration.h | 47 +++++++++---------- config/examples/wt150/Configuration.h | 47 +++++++++---------- 95 files changed, 2089 insertions(+), 2374 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index f31d4481b5..655ec94c7f 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/default/Configuration.h b/config/default/Configuration.h index f31d4481b5..655ec94c7f 100644 --- a/config/default/Configuration.h +++ b/config/default/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/3DFabXYZ/Migbot/Configuration.h b/config/examples/3DFabXYZ/Migbot/Configuration.h index 6b4724034b..7599a9a0b9 100644 --- a/config/examples/3DFabXYZ/Migbot/Configuration.h +++ b/config/examples/3DFabXYZ/Migbot/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 5 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 5 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 5 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 5 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/AlephObjects/TAZ4/Configuration.h b/config/examples/AlephObjects/TAZ4/Configuration.h index 982c8f9312..c5ce1e1027 100644 --- a/config/examples/AlephObjects/TAZ4/Configuration.h +++ b/config/examples/AlephObjects/TAZ4/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 250 #define HEATER_1_MAXTEMP 250 #define HEATER_2_MAXTEMP 250 #define HEATER_3_MAXTEMP 250 #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/AliExpress/CL-260/Configuration.h b/config/examples/AliExpress/CL-260/Configuration.h index dc9bf048b0..77f6b34d61 100644 --- a/config/examples/AliExpress/CL-260/Configuration.h +++ b/config/examples/AliExpress/CL-260/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/AliExpress/UM2pExt/Configuration.h b/config/examples/AliExpress/UM2pExt/Configuration.h index ec19c2f07c..797c135c29 100644 --- a/config/examples/AliExpress/UM2pExt/Configuration.h +++ b/config/examples/AliExpress/UM2pExt/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 130 +#define BED_MAXTEMP 130 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Anet/A2/Configuration.h b/config/examples/Anet/A2/Configuration.h index 1d16c9380e..a7b63a80ec 100644 --- a/config/examples/Anet/A2/Configuration.h +++ b/config/examples/Anet/A2/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Anet/A2plus/Configuration.h b/config/examples/Anet/A2plus/Configuration.h index 55c622329e..6b96efafc9 100644 --- a/config/examples/Anet/A2plus/Configuration.h +++ b/config/examples/Anet/A2plus/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Anet/A6/Configuration.h b/config/examples/Anet/A6/Configuration.h index 345aef2063..545ce98d9d 100644 --- a/config/examples/Anet/A6/Configuration.h +++ b/config/examples/Anet/A6/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 130 +#define BED_MAXTEMP 130 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Anet/A8/Configuration.h b/config/examples/Anet/A8/Configuration.h index a1dbf7bd4b..7300c8b658 100644 --- a/config/examples/Anet/A8/Configuration.h +++ b/config/examples/Anet/A8/Configuration.h @@ -389,37 +389,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 6 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 6 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 6 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 6 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 130 +#define BED_MAXTEMP 130 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/AnyCubic/i3/Configuration.h b/config/examples/AnyCubic/i3/Configuration.h index 307ab03f1f..f1989253a1 100644 --- a/config/examples/AnyCubic/i3/Configuration.h +++ b/config/examples/AnyCubic/i3/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/ArmEd/Configuration.h b/config/examples/ArmEd/Configuration.h index 2989c87b23..6299c2ba6b 100644 --- a/config/examples/ArmEd/Configuration.h +++ b/config/examples/ArmEd/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Azteeg/X5GT/Configuration.h b/config/examples/Azteeg/X5GT/Configuration.h index a8dabcf79c..cda5640be1 100644 --- a/config/examples/Azteeg/X5GT/Configuration.h +++ b/config/examples/Azteeg/X5GT/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/BIBO/TouchX/cyclops/Configuration.h b/config/examples/BIBO/TouchX/cyclops/Configuration.h index a440d1f42a..8ce90df050 100644 --- a/config/examples/BIBO/TouchX/cyclops/Configuration.h +++ b/config/examples/BIBO/TouchX/cyclops/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 285 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 115 +#define BED_MAXTEMP 115 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/BIBO/TouchX/default/Configuration.h b/config/examples/BIBO/TouchX/default/Configuration.h index b6d3ded901..db5c28f692 100644 --- a/config/examples/BIBO/TouchX/default/Configuration.h +++ b/config/examples/BIBO/TouchX/default/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 115 +#define BED_MAXTEMP 115 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/BQ/Hephestos/Configuration.h b/config/examples/BQ/Hephestos/Configuration.h index d6480f7e83..5844a4902a 100644 --- a/config/examples/BQ/Hephestos/Configuration.h +++ b/config/examples/BQ/Hephestos/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 260 #define HEATER_1_MAXTEMP 260 #define HEATER_2_MAXTEMP 260 #define HEATER_3_MAXTEMP 260 #define HEATER_4_MAXTEMP 260 #define HEATER_5_MAXTEMP 260 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/BQ/Hephestos_2/Configuration.h b/config/examples/BQ/Hephestos_2/Configuration.h index 2151e07dac..104c969402 100644 --- a/config/examples/BQ/Hephestos_2/Configuration.h +++ b/config/examples/BQ/Hephestos_2/Configuration.h @@ -396,30 +396,27 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 230 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 diff --git a/config/examples/BQ/WITBOX/Configuration.h b/config/examples/BQ/WITBOX/Configuration.h index 90641ec6c4..c0a8b05f76 100644 --- a/config/examples/BQ/WITBOX/Configuration.h +++ b/config/examples/BQ/WITBOX/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 260 #define HEATER_1_MAXTEMP 260 #define HEATER_2_MAXTEMP 260 #define HEATER_3_MAXTEMP 260 #define HEATER_4_MAXTEMP 260 #define HEATER_5_MAXTEMP 260 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Cartesio/Configuration.h b/config/examples/Cartesio/Configuration.h index 500d07b97a..7bdaf10205 100644 --- a/config/examples/Cartesio/Configuration.h +++ b/config/examples/Cartesio/Configuration.h @@ -389,37 +389,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 4 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 4 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 415 #define HEATER_1_MAXTEMP 415 #define HEATER_2_MAXTEMP 415 #define HEATER_3_MAXTEMP 415 #define HEATER_4_MAXTEMP 415 #define HEATER_5_MAXTEMP 415 -#define BED_MAXTEMP 165 +#define BED_MAXTEMP 165 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/CR-10/Configuration.h b/config/examples/Creality/CR-10/Configuration.h index 53b7cf6272..3c02fe56db 100644 --- a/config/examples/Creality/CR-10/Configuration.h +++ b/config/examples/Creality/CR-10/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/CR-10S/Configuration.h b/config/examples/Creality/CR-10S/Configuration.h index 1b491b8c97..b5ba96139f 100644 --- a/config/examples/Creality/CR-10S/Configuration.h +++ b/config/examples/Creality/CR-10S/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 250 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/CR-10_5S/Configuration.h b/config/examples/Creality/CR-10_5S/Configuration.h index 70d6ca38b1..d340acbdae 100644 --- a/config/examples/Creality/CR-10_5S/Configuration.h +++ b/config/examples/Creality/CR-10_5S/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 265 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/CR-10mini/Configuration.h b/config/examples/Creality/CR-10mini/Configuration.h index 82b42063b5..d6edbcdc59 100644 --- a/config/examples/Creality/CR-10mini/Configuration.h +++ b/config/examples/Creality/CR-10mini/Configuration.h @@ -397,37 +397,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/CR-8/Configuration.h b/config/examples/Creality/CR-8/Configuration.h index f7216847b2..5eafe174b5 100644 --- a/config/examples/Creality/CR-8/Configuration.h +++ b/config/examples/Creality/CR-8/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/Ender-2/Configuration.h b/config/examples/Creality/Ender-2/Configuration.h index 1731dbca68..da2dcb62fd 100644 --- a/config/examples/Creality/Ender-2/Configuration.h +++ b/config/examples/Creality/Ender-2/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 75 +#define BED_MAXTEMP 75 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/Ender-3/Configuration.h b/config/examples/Creality/Ender-3/Configuration.h index b599a5318e..4ffa6f9a66 100644 --- a/config/examples/Creality/Ender-3/Configuration.h +++ b/config/examples/Creality/Ender-3/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 125 +#define BED_MAXTEMP 125 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Creality/Ender-4/Configuration.h b/config/examples/Creality/Ender-4/Configuration.h index f43638adab..c5f92319d6 100644 --- a/config/examples/Creality/Ender-4/Configuration.h +++ b/config/examples/Creality/Ender-4/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Einstart-S/Configuration.h b/config/examples/Einstart-S/Configuration.h index 6837a12715..ad714d1d2a 100644 --- a/config/examples/Einstart-S/Configuration.h +++ b/config/examples/Einstart-S/Configuration.h @@ -390,37 +390,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Felix/Configuration.h b/config/examples/Felix/Configuration.h index c1f2d63cbb..8b8639aaf9 100644 --- a/config/examples/Felix/Configuration.h +++ b/config/examples/Felix/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 15 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 15 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Felix/DUAL/Configuration.h b/config/examples/Felix/DUAL/Configuration.h index 64a60cbd39..f173dc574c 100644 --- a/config/examples/Felix/DUAL/Configuration.h +++ b/config/examples/Felix/DUAL/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 15 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 15 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/FlashForge/CreatorPro/Configuration.h b/config/examples/FlashForge/CreatorPro/Configuration.h index bbfb027987..d4e075bb16 100644 --- a/config/examples/FlashForge/CreatorPro/Configuration.h +++ b/config/examples/FlashForge/CreatorPro/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/FolgerTech/i3-2020/Configuration.h b/config/examples/FolgerTech/i3-2020/Configuration.h index 79a320c71c..b91fa0d41c 100644 --- a/config/examples/FolgerTech/i3-2020/Configuration.h +++ b/config/examples/FolgerTech/i3-2020/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 245 #define HEATER_1_MAXTEMP 245 #define HEATER_2_MAXTEMP 245 #define HEATER_3_MAXTEMP 245 #define HEATER_4_MAXTEMP 245 #define HEATER_5_MAXTEMP 245 -#define BED_MAXTEMP 115 +#define BED_MAXTEMP 115 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Formbot/Raptor/Configuration.h b/config/examples/Formbot/Raptor/Configuration.h index 2994c1efc0..7749bd466f 100644 --- a/config/examples/Formbot/Raptor/Configuration.h +++ b/config/examples/Formbot/Raptor/Configuration.h @@ -433,38 +433,35 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 290 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #if ENABLED(BED_AC) - #define BED_MAXTEMP 150 + #define BED_MAXTEMP 150 #else - #define BED_MAXTEMP 100 + #define BED_MAXTEMP 100 #endif //=========================================================================== diff --git a/config/examples/Formbot/T_Rex_2+/Configuration.h b/config/examples/Formbot/T_Rex_2+/Configuration.h index 6ff1d327a9..b61fa02ea2 100644 --- a/config/examples/Formbot/T_Rex_2+/Configuration.h +++ b/config/examples/Formbot/T_Rex_2+/Configuration.h @@ -403,37 +403,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 410 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Formbot/T_Rex_3/Configuration.h b/config/examples/Formbot/T_Rex_3/Configuration.h index 48b7b2302e..3b98ac9e21 100644 --- a/config/examples/Formbot/T_Rex_3/Configuration.h +++ b/config/examples/Formbot/T_Rex_3/Configuration.h @@ -397,37 +397,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 410 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/A10M/Configuration.h b/config/examples/Geeetech/A10M/Configuration.h index 91da7829db..4d47e1c286 100644 --- a/config/examples/Geeetech/A10M/Configuration.h +++ b/config/examples/Geeetech/A10M/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/A20M/Configuration.h b/config/examples/Geeetech/A20M/Configuration.h index a6345ed295..3a049c4593 100644 --- a/config/examples/Geeetech/A20M/Configuration.h +++ b/config/examples/Geeetech/A20M/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/GT2560/Configuration.h b/config/examples/Geeetech/GT2560/Configuration.h index 8bf0b084fe..64e58d340c 100644 --- a/config/examples/Geeetech/GT2560/Configuration.h +++ b/config/examples/Geeetech/GT2560/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h b/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h index 7e20661ede..a6ec6b32c3 100644 --- a/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h +++ b/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/MeCreator2/Configuration.h b/config/examples/Geeetech/MeCreator2/Configuration.h index d5d541909a..055893e5ed 100644 --- a/config/examples/Geeetech/MeCreator2/Configuration.h +++ b/config/examples/Geeetech/MeCreator2/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h index 70128c3133..3bc9ce1369 100644 --- a/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 125 +#define BED_MAXTEMP 125 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h index fc800d8312..810814a2c0 100644 --- a/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 125 +#define BED_MAXTEMP 125 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h index 959a961141..7f89c34a72 100644 --- a/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h index fa60ead3ab..033cdad113 100644 --- a/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Infitary/i3-M508/Configuration.h b/config/examples/Infitary/i3-M508/Configuration.h index 9bd026c0c8..2cc02e8dfa 100644 --- a/config/examples/Infitary/i3-M508/Configuration.h +++ b/config/examples/Infitary/i3-M508/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 125 +#define BED_MAXTEMP 125 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/JGAurora/A5/Configuration.h b/config/examples/JGAurora/A5/Configuration.h index 013d7b29cb..8dad7d2ed6 100644 --- a/config/examples/JGAurora/A5/Configuration.h +++ b/config/examples/JGAurora/A5/Configuration.h @@ -393,37 +393,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 265 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/MakerParts/Configuration.h b/config/examples/MakerParts/Configuration.h index d27314af59..61833f7fa3 100644 --- a/config/examples/MakerParts/Configuration.h +++ b/config/examples/MakerParts/Configuration.h @@ -408,37 +408,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Malyan/M150/Configuration.h b/config/examples/Malyan/M150/Configuration.h index a6cdb98bf3..844944177c 100644 --- a/config/examples/Malyan/M150/Configuration.h +++ b/config/examples/Malyan/M150/Configuration.h @@ -396,37 +396,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Malyan/M200/Configuration.h b/config/examples/Malyan/M200/Configuration.h index dfa4436845..e431462148 100644 --- a/config/examples/Malyan/M200/Configuration.h +++ b/config/examples/Malyan/M200/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 250 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 100 +#define BED_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Micromake/C1/basic/Configuration.h b/config/examples/Micromake/C1/basic/Configuration.h index f1bb827cd2..122927a306 100644 --- a/config/examples/Micromake/C1/basic/Configuration.h +++ b/config/examples/Micromake/C1/basic/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Micromake/C1/enhanced/Configuration.h b/config/examples/Micromake/C1/enhanced/Configuration.h index 0d54b8d575..77fd7d7db3 100644 --- a/config/examples/Micromake/C1/enhanced/Configuration.h +++ b/config/examples/Micromake/C1/enhanced/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Mks/Robin/Configuration.h b/config/examples/Mks/Robin/Configuration.h index eed09a285f..fb3e3c6d69 100644 --- a/config/examples/Mks/Robin/Configuration.h +++ b/config/examples/Mks/Robin/Configuration.h @@ -389,37 +389,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Mks/Sbase/Configuration.h b/config/examples/Mks/Sbase/Configuration.h index 712a3d39c0..160b8855df 100644 --- a/config/examples/Mks/Sbase/Configuration.h +++ b/config/examples/Mks/Sbase/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Printrbot/PrintrboardG2/Configuration.h b/config/examples/Printrbot/PrintrboardG2/Configuration.h index ce508b9b9d..341135e3b0 100644 --- a/config/examples/Printrbot/PrintrboardG2/Configuration.h +++ b/config/examples/Printrbot/PrintrboardG2/Configuration.h @@ -389,37 +389,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/RapideLite/RL200/Configuration.h b/config/examples/RapideLite/RL200/Configuration.h index 65634f8410..533076ee02 100644 --- a/config/examples/RapideLite/RL200/Configuration.h +++ b/config/examples/RapideLite/RL200/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 250 #define HEATER_1_MAXTEMP 250 #define HEATER_2_MAXTEMP 250 #define HEATER_3_MAXTEMP 250 #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/RepRapPro/Huxley/Configuration.h b/config/examples/RepRapPro/Huxley/Configuration.h index 171ee06807..f214f8cd1d 100644 --- a/config/examples/RepRapPro/Huxley/Configuration.h +++ b/config/examples/RepRapPro/Huxley/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/RepRapWorld/Megatronics/Configuration.h b/config/examples/RepRapWorld/Megatronics/Configuration.h index 392222916f..8e678816e2 100644 --- a/config/examples/RepRapWorld/Megatronics/Configuration.h +++ b/config/examples/RepRapWorld/Megatronics/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/RigidBot/Configuration.h b/config/examples/RigidBot/Configuration.h index a9a00acac8..36a5f3f114 100644 --- a/config/examples/RigidBot/Configuration.h +++ b/config/examples/RigidBot/Configuration.h @@ -391,37 +391,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT //#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/SCARA/Configuration.h b/config/examples/SCARA/Configuration.h index e4a785f2ba..a94e4da75e 100644 --- a/config/examples/SCARA/Configuration.h +++ b/config/examples/SCARA/Configuration.h @@ -419,37 +419,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 3 // (seconds) -#define TEMP_HYSTERESIS 2 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 3 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_HYSTERESIS 2 // (°C) Temperature proximity considered "close enough" to the target +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/STM32F10/Configuration.h b/config/examples/STM32F10/Configuration.h index 9dccbbb31b..e6db23d988 100644 --- a/config/examples/STM32F10/Configuration.h +++ b/config/examples/STM32F10/Configuration.h @@ -389,37 +389,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/STM32F4/Configuration.h b/config/examples/STM32F4/Configuration.h index b18e5089aa..894e4f79a3 100644 --- a/config/examples/STM32F4/Configuration.h +++ b/config/examples/STM32F4/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Sanguinololu/Configuration.h b/config/examples/Sanguinololu/Configuration.h index cc1a9b4604..979c04b98d 100644 --- a/config/examples/Sanguinololu/Configuration.h +++ b/config/examples/Sanguinololu/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/TheBorg/Configuration.h b/config/examples/TheBorg/Configuration.h index 090ddf338e..d4a79c4a65 100644 --- a/config/examples/TheBorg/Configuration.h +++ b/config/examples/TheBorg/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/TinyBoy2/Configuration.h b/config/examples/TinyBoy2/Configuration.h index fd04a56637..74cfff7f32 100644 --- a/config/examples/TinyBoy2/Configuration.h +++ b/config/examples/TinyBoy2/Configuration.h @@ -415,37 +415,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 250 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 100 +#define BED_MAXTEMP 100 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Tronxy/X1/Configuration.h b/config/examples/Tronxy/X1/Configuration.h index 6bc1477459..cf330fe3f8 100644 --- a/config/examples/Tronxy/X1/Configuration.h +++ b/config/examples/Tronxy/X1/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 260 #define HEATER_1_MAXTEMP 260 #define HEATER_2_MAXTEMP 260 #define HEATER_3_MAXTEMP 260 #define HEATER_4_MAXTEMP 260 #define HEATER_5_MAXTEMP 260 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Tronxy/X3A/Configuration.h b/config/examples/Tronxy/X3A/Configuration.h index 7230e66a60..62c21a0955 100644 --- a/config/examples/Tronxy/X3A/Configuration.h +++ b/config/examples/Tronxy/X3A/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 130 +#define BED_MAXTEMP 130 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Tronxy/X5S-2E/Configuration.h b/config/examples/Tronxy/X5S-2E/Configuration.h index 0a544b169d..9f87f7819c 100644 --- a/config/examples/Tronxy/X5S-2E/Configuration.h +++ b/config/examples/Tronxy/X5S-2E/Configuration.h @@ -390,30 +390,27 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) // Tronxy X5S-2E: // WARNING: Never exceed 260C. The OEM stock model uses low temperature heat breaks with PTFE-lining. #define HEATER_0_MAXTEMP 260 @@ -424,7 +421,7 @@ #define HEATER_5_MAXTEMP 260 // Tronxy X5S-2E: // The OEM stock model uses a clone MK3a 300 @ 12V with no insulation and can reach a maximum 70C at 25C ambient. -#define BED_MAXTEMP 81 +#define BED_MAXTEMP 81 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Tronxy/X5S/Configuration.h b/config/examples/Tronxy/X5S/Configuration.h index 6ee62b534b..dbedb22c5b 100644 --- a/config/examples/Tronxy/X5S/Configuration.h +++ b/config/examples/Tronxy/X5S/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Tronxy/XY100/Configuration.h b/config/examples/Tronxy/XY100/Configuration.h index 0229444631..a64bfbcfd7 100644 --- a/config/examples/Tronxy/XY100/Configuration.h +++ b/config/examples/Tronxy/XY100/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/UltiMachine/Archim1/Configuration.h b/config/examples/UltiMachine/Archim1/Configuration.h index e3155357a9..26aa690840 100644 --- a/config/examples/UltiMachine/Archim1/Configuration.h +++ b/config/examples/UltiMachine/Archim1/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/UltiMachine/Archim2/Configuration.h b/config/examples/UltiMachine/Archim2/Configuration.h index 8553fbaf0e..ac16650ac3 100644 --- a/config/examples/UltiMachine/Archim2/Configuration.h +++ b/config/examples/UltiMachine/Archim2/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/VORONDesign/Configuration.h b/config/examples/VORONDesign/Configuration.h index 54e4a44f49..37b7b28ea2 100644 --- a/config/examples/VORONDesign/Configuration.h +++ b/config/examples/VORONDesign/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Velleman/K8200/Configuration.h b/config/examples/Velleman/K8200/Configuration.h index 704c40cbcf..209f96bd65 100644 --- a/config/examples/Velleman/K8200/Configuration.h +++ b/config/examples/Velleman/K8200/Configuration.h @@ -408,37 +408,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Velleman/K8400/Configuration.h b/config/examples/Velleman/K8400/Configuration.h index 97d4340a19..22b00725bf 100644 --- a/config/examples/Velleman/K8400/Configuration.h +++ b/config/examples/Velleman/K8400/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 2 // (seconds) -#define TEMP_HYSTERESIS 5 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 2 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 5 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Velleman/K8400/Dual-head/Configuration.h b/config/examples/Velleman/K8400/Dual-head/Configuration.h index 46fa6748ad..cb86599e40 100644 --- a/config/examples/Velleman/K8400/Dual-head/Configuration.h +++ b/config/examples/Velleman/K8400/Dual-head/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 2 // (seconds) -#define TEMP_HYSTERESIS 5 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 2 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_HYSTERESIS 5 // (°C) Temperature proximity considered "close enough" to the target +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/WASP/PowerWASP/Configuration.h b/config/examples/WASP/PowerWASP/Configuration.h index 0378317d9f..687b8863ec 100644 --- a/config/examples/WASP/PowerWASP/Configuration.h +++ b/config/examples/WASP/PowerWASP/Configuration.h @@ -407,37 +407,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 5 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 5 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 230 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/Wanhao/Duplicator 6/Configuration.h b/config/examples/Wanhao/Duplicator 6/Configuration.h index 3e7abb3aba..05e3e9ca82 100644 --- a/config/examples/Wanhao/Duplicator 6/Configuration.h +++ b/config/examples/Wanhao/Duplicator 6/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 260 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/adafruit/ST7565/Configuration.h b/config/examples/adafruit/ST7565/Configuration.h index 0046664dd3..05a6608c20 100644 --- a/config/examples/adafruit/ST7565/Configuration.h +++ b/config/examples/adafruit/ST7565/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/Anycubic/Kossel/Configuration.h b/config/examples/delta/Anycubic/Kossel/Configuration.h index ba5368bdb5..34bf408191 100644 --- a/config/examples/delta/Anycubic/Kossel/Configuration.h +++ b/config/examples/delta/Anycubic/Kossel/Configuration.h @@ -409,37 +409,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 120 +#define BED_MAXTEMP 120 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/FLSUN/auto_calibrate/Configuration.h b/config/examples/delta/FLSUN/auto_calibrate/Configuration.h index deeb1401ba..b847fceafd 100644 --- a/config/examples/delta/FLSUN/auto_calibrate/Configuration.h +++ b/config/examples/delta/FLSUN/auto_calibrate/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 250 #define HEATER_1_MAXTEMP 250 #define HEATER_2_MAXTEMP 250 #define HEATER_3_MAXTEMP 250 #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 -#define BED_MAXTEMP 115 +#define BED_MAXTEMP 115 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/FLSUN/kossel/Configuration.h b/config/examples/delta/FLSUN/kossel/Configuration.h index 9a2d70407c..5ec1e117ce 100644 --- a/config/examples/delta/FLSUN/kossel/Configuration.h +++ b/config/examples/delta/FLSUN/kossel/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 250 #define HEATER_1_MAXTEMP 250 #define HEATER_2_MAXTEMP 250 #define HEATER_3_MAXTEMP 250 #define HEATER_4_MAXTEMP 250 #define HEATER_5_MAXTEMP 250 -#define BED_MAXTEMP 115 +#define BED_MAXTEMP 115 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/FLSUN/kossel_mini/Configuration.h b/config/examples/delta/FLSUN/kossel_mini/Configuration.h index 085142651d..89202af3f4 100644 --- a/config/examples/delta/FLSUN/kossel_mini/Configuration.h +++ b/config/examples/delta/FLSUN/kossel_mini/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/Geeetech/Rostock 301/Configuration.h b/config/examples/delta/Geeetech/Rostock 301/Configuration.h index 48c99c8b70..f87081e95d 100644 --- a/config/examples/delta/Geeetech/Rostock 301/Configuration.h +++ b/config/examples/delta/Geeetech/Rostock 301/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/Hatchbox_Alpha/Configuration.h b/config/examples/delta/Hatchbox_Alpha/Configuration.h index 5037d498b7..0755ccdedc 100644 --- a/config/examples/delta/Hatchbox_Alpha/Configuration.h +++ b/config/examples/delta/Hatchbox_Alpha/Configuration.h @@ -393,37 +393,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/MKS/SBASE/Configuration.h b/config/examples/delta/MKS/SBASE/Configuration.h index b8c3b29d95..9dd59fe1c5 100644 --- a/config/examples/delta/MKS/SBASE/Configuration.h +++ b/config/examples/delta/MKS/SBASE/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/Tevo Little Monster/Configuration.h b/config/examples/delta/Tevo Little Monster/Configuration.h index ef72b1bd6d..92f594b932 100644 --- a/config/examples/delta/Tevo Little Monster/Configuration.h +++ b/config/examples/delta/Tevo Little Monster/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/generic/Configuration.h b/config/examples/delta/generic/Configuration.h index 4ff806cf65..d024ac4126 100644 --- a/config/examples/delta/generic/Configuration.h +++ b/config/examples/delta/generic/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/kossel_mini/Configuration.h b/config/examples/delta/kossel_mini/Configuration.h index aa8f30a6a8..d4510b9266 100644 --- a/config/examples/delta/kossel_mini/Configuration.h +++ b/config/examples/delta/kossel_mini/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/kossel_pro/Configuration.h b/config/examples/delta/kossel_pro/Configuration.h index c0e7ebb5ad..575592708f 100644 --- a/config/examples/delta/kossel_pro/Configuration.h +++ b/config/examples/delta/kossel_pro/Configuration.h @@ -392,37 +392,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/delta/kossel_xl/Configuration.h b/config/examples/delta/kossel_xl/Configuration.h index 16de2a6093..4244c1075e 100644 --- a/config/examples/delta/kossel_xl/Configuration.h +++ b/config/examples/delta/kossel_xl/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/gCreate/gMax1.5+/Configuration.h b/config/examples/gCreate/gMax1.5+/Configuration.h index 65bc3be325..b52d56b76d 100644 --- a/config/examples/gCreate/gMax1.5+/Configuration.h +++ b/config/examples/gCreate/gMax1.5+/Configuration.h @@ -396,37 +396,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 16 // (seconds) -#define TEMP_HYSTERESIS 12 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 5 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 16 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 5 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 12 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 245 #define HEATER_1_MAXTEMP 245 #define HEATER_2_MAXTEMP 245 #define HEATER_3_MAXTEMP 245 #define HEATER_4_MAXTEMP 245 #define HEATER_5_MAXTEMP 245 -#define BED_MAXTEMP 115 +#define BED_MAXTEMP 115 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/makibox/Configuration.h b/config/examples/makibox/Configuration.h index 3a58f2fed0..7e6ad9e8e3 100644 --- a/config/examples/makibox/Configuration.h +++ b/config/examples/makibox/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/stm32f103ret6/Configuration.h b/config/examples/stm32f103ret6/Configuration.h index 325527951d..e3bc451cd6 100644 --- a/config/examples/stm32f103ret6/Configuration.h +++ b/config/examples/stm32f103ret6/Configuration.h @@ -389,37 +389,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/tvrrug/Round2/Configuration.h b/config/examples/tvrrug/Round2/Configuration.h index 467f780a4c..31642b2ccc 100644 --- a/config/examples/tvrrug/Round2/Configuration.h +++ b/config/examples/tvrrug/Round2/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================ diff --git a/config/examples/wt150/Configuration.h b/config/examples/wt150/Configuration.h index 48e13f0d3d..85e0231d23 100644 --- a/config/examples/wt150/Configuration.h +++ b/config/examples/wt150/Configuration.h @@ -388,37 +388,34 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -// Extruder temperature must be close to target for this long before M109 returns success -#define TEMP_RESIDENCY_TIME 10 // (seconds) -#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// Bed temperature must be close to target for this long before M190 returns success -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) -#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one -#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early. - -// The minimal temperature defines the temperature below which the heater will not be enabled It is used -// to check that the wiring to the thermistor is not broken. -// Otherwise this would lead to the heater being powered on all the time. -#define HEATER_0_MINTEMP 5 -#define HEATER_1_MINTEMP 5 -#define HEATER_2_MINTEMP 5 -#define HEATER_3_MINTEMP 5 -#define HEATER_4_MINTEMP 5 -#define HEATER_5_MINTEMP 5 -#define BED_MINTEMP 5 - -// When temperature exceeds max temp, your heater will be switched off. -// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure! -// You should use MINTEMP for thermistor short/failure protection. +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target + +// Below this temperature the heater will be switched off +// because it probably indicates a broken thermistor wire. +#define HEATER_0_MINTEMP 5 +#define HEATER_1_MINTEMP 5 +#define HEATER_2_MINTEMP 5 +#define HEATER_3_MINTEMP 5 +#define HEATER_4_MINTEMP 5 +#define HEATER_5_MINTEMP 5 +#define BED_MINTEMP 5 + +// Above this temperature the heater will be switched off. +// This can protect components from overheating, but NOT from shorts and failures. +// (Use MINTEMP for thermistor short/failure protection.) #define HEATER_0_MAXTEMP 275 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 #define HEATER_4_MAXTEMP 275 #define HEATER_5_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 150 //=========================================================================== //============================= PID Settings ================================