Browse Source

Cosmetic tweaks from dev

pull/1/head
Scott Lahteine 9 years ago
parent
commit
988332c67a
  1. 2
      Marlin/scripts/createTemperatureLookupMarlin.py

2
Marlin/scripts/createTemperatureLookupMarlin.py

@ -26,7 +26,7 @@ import getopt
ZERO = 273.15 # zero point of Kelvin scale ZERO = 273.15 # zero point of Kelvin scale
VADC = 5 # ADC voltage VADC = 5 # ADC voltage
VCC = 5 # supply voltage VCC = 5 # supply voltage
ARES = 2**10 # 10 Bit ADC resolution ARES = pow(2,10) # 10 Bit ADC resolution
VSTEP = VADC / ARES # ADC voltage resolution VSTEP = VADC / ARES # ADC voltage resolution
TMIN = 0 # lowest temperature in table TMIN = 0 # lowest temperature in table
TMAX = 350 # highest temperature in table TMAX = 350 # highest temperature in table

Loading…
Cancel
Save