@ -624,14 +624,15 @@ |
|
|
|
#endif |
|
|
|
|
|
|
|
/**
|
|
|
|
* Enable if probing seems unreliable. Heaters and/or fans - consistent with the |
|
|
|
* options selected below - will be disabled during probing so as to minimize |
|
|
|
* potential EM interference by quieting/silencing the source of the 'noise' (the change |
|
|
|
* in current flowing through the wires). This is likely most useful to users of the |
|
|
|
* BLTouch probe, but may also help those with inductive or other probe types. |
|
|
|
* Enable one or more of the following if probing seems unreliable. |
|
|
|
* Heaters and/or fans can be disabled during probing to minimize electrical |
|
|
|
* noise. A delay can also be added to allow noise and vibration to settle. |
|
|
|
* These options are most useful for the BLTouch probe, but may also improve |
|
|
|
* readings with inductive probes and piezo sensors. |
|
|
|
*/ |
|
|
|
//#define PROBING_HEATERS_OFF // Turn heaters off when probing
|
|
|
|
//#define PROBING_FANS_OFF // Turn fans off when probing
|
|
|
|
//#define DELAY_BEFORE_PROBING 200 // (ms) To prevent vibrations from triggering piezo sensors
|
|
|
|
|
|
|
|
// A probe that is deployed and stowed with a solenoid pin (SOL1_PIN)
|
|
|
|
//#define SOLENOID_PROBE
|
|
|
|