Browse Source

Sanity check 3-point defines

Fixes #17870
vanilla_fb_2.0.x
Scott Lahteine 5 years ago
parent
commit
86c1125380
  1. 6
      Marlin/src/inc/Conditionals_post.h

6
Marlin/src/inc/Conditionals_post.h

@ -2338,9 +2338,13 @@
#undef MESH_MAX_Y
#endif
#if defined(PROBE_PT_1_X) && defined(PROBE_PT_2_X) && defined(PROBE_PT_3_X) && defined(PROBE_PT_1_Y) && defined(PROBE_PT_2_Y) && defined(PROBE_PT_3_Y)
#define _POINT_COUNT (defined(PROBE_PT_1_X) + defined(PROBE_PT_2_X) + defined(PROBE_PT_3_X) + defined(PROBE_PT_1_Y) + defined(PROBE_PT_2_Y) + defined(PROBE_PT_3_Y))
#if _POINT_COUNT == 6
#define HAS_FIXED_3POINT 1
#elif _POINT_COUNT > 0
#error "For 3-Point Leveling all XY points must be defined (or none for the defaults)."
#endif
#undef _POINT_COUNT
/**