Browse Source

Configs for Prusa i3 Pro B GT2560 Rev.A Plus (#9505)

One without probe and one with BLTOUCH.
pull/1/head
Scott Lahteine 7 years ago
committed by GitHub
parent
commit
8558264514
No known key found for this signature in database GPG Key ID: 4AEE18F83AFDEB23
  1. 39
      Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/README.md
  2. 1826
      Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h
  3. 1825
      Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h

39
Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/README.md

@ -0,0 +1,39 @@
These are example configurations for the low-cost [Acrylic Prusa I3 pro B 3D Printer DIY kit](http://www.geeetech.com/acrylic-geeetech-prusa-i3-pro-b-3d-printer-diy-kit-p-917.html) and the [3DTouch auto bed leveling sensor](http://www.geeetech.com/geeetech-3dtouch-auto-bed-leveling-sensor-for-3d-printer-p-1010.html) based on:
- `../GT2560/`
- [Marlin 1.1.4 With 3DTouch / BLTouch for i3 Pro B](https://www.geeetech.com/forum/viewtopic.php?t=19846)
The main characteristics of these configurations are:
- The defined motherboard is `BOARD_GT2560_REV_A_PLUS`.
- Travel limits are adjusted to the printer bed size and position.
- An example `SKEW_CORRECTION` for a particular printer is enabled. See comments below about how to adjust it to a particular printer.
- Using the LCD controller for bed leveling is enabled.
- `PROBE_MANUALLY` is enabled, which *provides a means to do "Auto" Bed Leveling without a probe*.
- The `LEVEL_BED_CORNERS` option for manual bed adjustment is enabled.
- Bilinear bed leveling is enabled, the boundaries for probing are adjusted to the glass size, and extrapolation is enabled.
- `PRINTCOUNTER` is enabled, in order to track statistical data.
- `INDIVIDUAL_AXIS_HOMING_MENU` is enabled, which adds individual axis homing items (Home X, Home Y, and Home Z) to the LCD menu.
- The speaker is enabled for the UI feedback.
- `bltouch` variant:
- `USE_ZMAX_PLUG` is enabled. See comments about connections below.
- Heaters and fans are turned off when probing.
- Multiple probing is set to 3.
# First-time configuration
## Skew factor
The skew factor must be adjusted for each printer:
- First, uncomment `#define XY_SKEW_FACTOR 0.0`, compile and upload the firmware.
- Then, print [YACS (Yet Another Calibration Square)](https://www.thingiverse.com/thing:2563185). Hint, scale it considering a margin for brim (if used). The larger, the better to make error measurements.
- Measure the printed part according to the comments in the example configuration file, and set `XY_DIAG_AC`, `XY_DIAG_BD` and `Y_SIDE_AD`.
- Last, comment `#define XY_SKEW_FACTOR 0.0` again, compile and upload.
## 3DTouch auto leveling sensor
- Print a suitable mount to attach the sensor to the printer. The example configuration file is adjusted to http://www.geeetech.com/wiki/images/6/61/3DTouch_auto_leveling_sensor-1.zip
- Unlike suggested in [geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor](https://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor), the existing end stop switch is expected to be kept connected to Z_MIN. So, the sensor is to be connected to Z_MAX, according to Marlin's default settings. Furthermore, GT2560-A+ provides a connector for the servo next to thermistor connectors (see [GT2560](https://www.geeetech.com/wiki/images/thumb/4/45/GT2560_wiring.jpg/700px-GT2560_wiring.jpg) and [GT2560-A+](http://i.imgur.com/E0t34VU.png)).
- Be careful to respect the polarity of the sensor when connecting it to the GT2560-A+. Unlike end stops, reversing the connection will prevent the sensor from working properly.
- [Test](http://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor#Testing) and [calibrate](https://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor#Calibration) the sensor.

1826
Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h

File diff suppressed because it is too large

1825
Marlin/src/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h

File diff suppressed because it is too large
Loading…
Cancel
Save