@ -14,11 +14,14 @@ |
|
|
|
#endif |
|
|
|
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
|
|
|
|
|
|
|
//// Heating sanity check:
|
|
|
|
// This waits for the watch period in milliseconds whenever an M104 or M109 increases the target temperature
|
|
|
|
// If the temperature has not increased at the end of that period, the target temperature is set to zero.
|
|
|
|
// It can be reset with another M104/M109. This check is also only triggered if the target temperature and
|
|
|
|
// the current temperature differ by at least 2x WATCH_TEMP_INCREASE
|
|
|
|
/**
|
|
|
|
* Heating Sanity Check |
|
|
|
* |
|
|
|
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds, |
|
|
|
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a |
|
|
|
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target |
|
|
|
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius. |
|
|
|
*/ |
|
|
|
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
|
|
|
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
|
|
|
|
|
|
|