@ -783,11 +783,14 @@ static_assert(Y_MAX_LENGTH >= Y_BED_SIZE, "Movement bounds (Y_MIN_POS, Y_MAX_POS |
|
|
|
#endif |
|
|
|
|
|
|
|
#if !defined(TARGET_LPC1768) && ANY( \ |
|
|
|
ENDSTOPPULLDOWNS, \ |
|
|
|
ENDSTOPPULLDOWN_XMAX, ENDSTOPPULLDOWN_YMAX, \ |
|
|
|
ENDSTOPPULLDOWN_ZMAX, ENDSTOPPULLDOWN_XMIN, \ |
|
|
|
ENDSTOPPULLDOWN_YMIN, ENDSTOPPULLDOWN_ZMIN \ |
|
|
|
) |
|
|
|
ENDSTOPPULLDOWNS, ENDSTOPPULLDOWN_ZMIN_PROBE, \ |
|
|
|
ENDSTOPPULLDOWN_XMAX, ENDSTOPPULLDOWN_YMAX, ENDSTOPPULLDOWN_ZMAX, \ |
|
|
|
ENDSTOPPULLDOWN_XMIN, ENDSTOPPULLDOWN_YMIN, ENDSTOPPULLDOWN_ZMIN, \ |
|
|
|
FIL_RUNOUT_PULLDOWN, \ |
|
|
|
FIL_RUNOUT1_PULLDOWN, FIL_RUNOUT2_PULLDOWN, FIL_RUNOUT3_PULLDOWN, FIL_RUNOUT4_PULLDOWN, \ |
|
|
|
FIL_RUNOUT5_PULLDOWN, FIL_RUNOUT6_PULLDOWN, FIL_RUNOUT7_PULLDOWN, FIL_RUNOUT8_PULLDOWN, \ |
|
|
|
POWER_LOSS_PULLDOWN, CALIBRATION_PIN_PULLDOWN \ |
|
|
|
) |
|
|
|
#error "PULLDOWN pin mode is not available on the selected board." |
|
|
|
#endif |
|
|
|
|
|
|
@ -1146,6 +1149,9 @@ static_assert(Y_MAX_LENGTH >= Y_BED_SIZE, "Movement bounds (Y_MIN_POS, Y_MAX_POS |
|
|
|
#elif ENABLED(SINGLENOZZLE) |
|
|
|
|
|
|
|
#error "SINGLENOZZLE requires 2 or more EXTRUDERS." |
|
|
|
#if ENABLED(PID_PARAMS_PER_HOTEND) |
|
|
|
#error "PID_PARAMS_PER_HOTEND must be disabled when using any SINGLENOZZLE extruder." |
|
|
|
#endif |
|
|
|
|
|
|
|
#endif |
|
|
|
|
|
|
|