diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index 09d5f3f1f1..7601dd65a3 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/default/Configuration.h b/Marlin/src/config/default/Configuration.h index 09d5f3f1f1..7601dd65a3 100644 --- a/Marlin/src/config/default/Configuration.h +++ b/Marlin/src/config/default/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/AlephObjects/TAZ4/Configuration.h b/Marlin/src/config/examples/AlephObjects/TAZ4/Configuration.h index b09a0eea12..eebbe77994 100644 --- a/Marlin/src/config/examples/AlephObjects/TAZ4/Configuration.h +++ b/Marlin/src/config/examples/AlephObjects/TAZ4/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/AliExpress/CL-260/Configuration.h b/Marlin/src/config/examples/AliExpress/CL-260/Configuration.h index bb56793f61..b64643537c 100644 --- a/Marlin/src/config/examples/AliExpress/CL-260/Configuration.h +++ b/Marlin/src/config/examples/AliExpress/CL-260/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Anet/A6/Configuration.h b/Marlin/src/config/examples/Anet/A6/Configuration.h index cd3434544a..feec3b2c10 100644 --- a/Marlin/src/config/examples/Anet/A6/Configuration.h +++ b/Marlin/src/config/examples/Anet/A6/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Anet/A8/Configuration.h b/Marlin/src/config/examples/Anet/A8/Configuration.h index d1a195c2d2..d352828a73 100644 --- a/Marlin/src/config/examples/Anet/A8/Configuration.h +++ b/Marlin/src/config/examples/Anet/A8/Configuration.h @@ -254,7 +254,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Azteeg/X5GT/Configuration.h b/Marlin/src/config/examples/Azteeg/X5GT/Configuration.h index 2370f431dd..bdbd3be4c0 100644 --- a/Marlin/src/config/examples/Azteeg/X5GT/Configuration.h +++ b/Marlin/src/config/examples/Azteeg/X5GT/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/BQ/Hephestos/Configuration.h b/Marlin/src/config/examples/BQ/Hephestos/Configuration.h index 8ce581742f..4cf6844c05 100644 --- a/Marlin/src/config/examples/BQ/Hephestos/Configuration.h +++ b/Marlin/src/config/examples/BQ/Hephestos/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/BQ/Hephestos_2/Configuration.h b/Marlin/src/config/examples/BQ/Hephestos_2/Configuration.h index 9c2634955b..d0378cdddc 100644 --- a/Marlin/src/config/examples/BQ/Hephestos_2/Configuration.h +++ b/Marlin/src/config/examples/BQ/Hephestos_2/Configuration.h @@ -252,7 +252,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/BQ/WITBOX/Configuration.h b/Marlin/src/config/examples/BQ/WITBOX/Configuration.h index f8f91d3a53..1fcc1f8b6a 100644 --- a/Marlin/src/config/examples/BQ/WITBOX/Configuration.h +++ b/Marlin/src/config/examples/BQ/WITBOX/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Cartesio/Configuration.h b/Marlin/src/config/examples/Cartesio/Configuration.h index fa4c9efea2..c7ade6ee6d 100644 --- a/Marlin/src/config/examples/Cartesio/Configuration.h +++ b/Marlin/src/config/examples/Cartesio/Configuration.h @@ -254,7 +254,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Creality/CR-10/Configuration.h b/Marlin/src/config/examples/Creality/CR-10/Configuration.h index 3f18a3229a..1719f0846a 100755 --- a/Marlin/src/config/examples/Creality/CR-10/Configuration.h +++ b/Marlin/src/config/examples/Creality/CR-10/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Felix/Configuration.h b/Marlin/src/config/examples/Felix/Configuration.h index aa5ab9c370..052a16779c 100644 --- a/Marlin/src/config/examples/Felix/Configuration.h +++ b/Marlin/src/config/examples/Felix/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Felix/DUAL/Configuration.h b/Marlin/src/config/examples/Felix/DUAL/Configuration.h index f4ce09ef77..83a6ab34fe 100644 --- a/Marlin/src/config/examples/Felix/DUAL/Configuration.h +++ b/Marlin/src/config/examples/Felix/DUAL/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/FolgerTech/i3-2020/Configuration.h b/Marlin/src/config/examples/FolgerTech/i3-2020/Configuration.h index 4e8d969be7..dafd79109f 100644 --- a/Marlin/src/config/examples/FolgerTech/i3-2020/Configuration.h +++ b/Marlin/src/config/examples/FolgerTech/i3-2020/Configuration.h @@ -254,7 +254,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Geeetech/GT2560/Configuration.h b/Marlin/src/config/examples/Geeetech/GT2560/Configuration.h index 09e78efdeb..9f2c25d385 100644 --- a/Marlin/src/config/examples/Geeetech/GT2560/Configuration.h +++ b/Marlin/src/config/examples/Geeetech/GT2560/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h b/Marlin/src/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h index 15a7290fea..2a7033879d 100644 --- a/Marlin/src/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h +++ b/Marlin/src/config/examples/Geeetech/I3_Pro_X-GT2560/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Infitary/i3-M508/Configuration.h b/Marlin/src/config/examples/Infitary/i3-M508/Configuration.h index 2e3484e4c3..ee4c0b0884 100644 --- a/Marlin/src/config/examples/Infitary/i3-M508/Configuration.h +++ b/Marlin/src/config/examples/Infitary/i3-M508/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/MakerParts/Configuration.h b/Marlin/src/config/examples/MakerParts/Configuration.h index f28444bdf5..4ef181ca79 100644 --- a/Marlin/src/config/examples/MakerParts/Configuration.h +++ b/Marlin/src/config/examples/MakerParts/Configuration.h @@ -273,7 +273,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Malyan/M150/Configuration.h b/Marlin/src/config/examples/Malyan/M150/Configuration.h index 2d2bedee92..b247802edf 100644 --- a/Marlin/src/config/examples/Malyan/M150/Configuration.h +++ b/Marlin/src/config/examples/Malyan/M150/Configuration.h @@ -258,7 +258,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Malyan/M200/Configuration.h b/Marlin/src/config/examples/Malyan/M200/Configuration.h index a308d28a1b..74744cfa66 100644 --- a/Marlin/src/config/examples/Malyan/M200/Configuration.h +++ b/Marlin/src/config/examples/Malyan/M200/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Micromake/C1/basic/Configuration.h b/Marlin/src/config/examples/Micromake/C1/basic/Configuration.h index b828688c3f..d5bcd1a582 100644 --- a/Marlin/src/config/examples/Micromake/C1/basic/Configuration.h +++ b/Marlin/src/config/examples/Micromake/C1/basic/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Micromake/C1/enhanced/Configuration.h b/Marlin/src/config/examples/Micromake/C1/enhanced/Configuration.h index dc6d8cbbbf..90018c4f14 100644 --- a/Marlin/src/config/examples/Micromake/C1/enhanced/Configuration.h +++ b/Marlin/src/config/examples/Micromake/C1/enhanced/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Mks/Sbase/Configuration.h b/Marlin/src/config/examples/Mks/Sbase/Configuration.h index e79b3f4756..c99d9af893 100644 --- a/Marlin/src/config/examples/Mks/Sbase/Configuration.h +++ b/Marlin/src/config/examples/Mks/Sbase/Configuration.h @@ -254,7 +254,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/RepRapWorld/Megatronics/Configuration.h b/Marlin/src/config/examples/RepRapWorld/Megatronics/Configuration.h index b03412dd11..6e4b8f718f 100644 --- a/Marlin/src/config/examples/RepRapWorld/Megatronics/Configuration.h +++ b/Marlin/src/config/examples/RepRapWorld/Megatronics/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/RigidBot/Configuration.h b/Marlin/src/config/examples/RigidBot/Configuration.h index 26e341d458..4b4219e986 100644 --- a/Marlin/src/config/examples/RigidBot/Configuration.h +++ b/Marlin/src/config/examples/RigidBot/Configuration.h @@ -256,7 +256,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/SCARA/Configuration.h b/Marlin/src/config/examples/SCARA/Configuration.h index 28ee15753b..aba6a47e2c 100644 --- a/Marlin/src/config/examples/SCARA/Configuration.h +++ b/Marlin/src/config/examples/SCARA/Configuration.h @@ -283,7 +283,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/STM32F10/Configuration.h b/Marlin/src/config/examples/STM32F10/Configuration.h index 424f9539ae..bebd2ff553 100644 --- a/Marlin/src/config/examples/STM32F10/Configuration.h +++ b/Marlin/src/config/examples/STM32F10/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Sanguinololu/Configuration.h b/Marlin/src/config/examples/Sanguinololu/Configuration.h index 2b051c2ddd..8f90e4f9a0 100644 --- a/Marlin/src/config/examples/Sanguinololu/Configuration.h +++ b/Marlin/src/config/examples/Sanguinololu/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/TinyBoy2/Configuration.h b/Marlin/src/config/examples/TinyBoy2/Configuration.h index 78c00cc31e..645f94e17f 100644 --- a/Marlin/src/config/examples/TinyBoy2/Configuration.h +++ b/Marlin/src/config/examples/TinyBoy2/Configuration.h @@ -275,7 +275,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Tronxy/X1/Configuration.h b/Marlin/src/config/examples/Tronxy/X1/Configuration.h index 39033fbbf1..4fea1c8411 100644 --- a/Marlin/src/config/examples/Tronxy/X1/Configuration.h +++ b/Marlin/src/config/examples/Tronxy/X1/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/UltiMachine/Archim2/Configuration.h b/Marlin/src/config/examples/UltiMachine/Archim2/Configuration.h index 3551116ced..32cd47806f 100644 --- a/Marlin/src/config/examples/UltiMachine/Archim2/Configuration.h +++ b/Marlin/src/config/examples/UltiMachine/Archim2/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Velleman/K8200/Configuration.h b/Marlin/src/config/examples/Velleman/K8200/Configuration.h index e6d2c26fc1..086060e4f0 100644 --- a/Marlin/src/config/examples/Velleman/K8200/Configuration.h +++ b/Marlin/src/config/examples/Velleman/K8200/Configuration.h @@ -273,7 +273,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Velleman/K8400/Configuration.h b/Marlin/src/config/examples/Velleman/K8400/Configuration.h index 4f7be99557..f6d8efa009 100644 --- a/Marlin/src/config/examples/Velleman/K8400/Configuration.h +++ b/Marlin/src/config/examples/Velleman/K8400/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Velleman/K8400/Dual-head/Configuration.h b/Marlin/src/config/examples/Velleman/K8400/Dual-head/Configuration.h index 6fe9563617..2d03ef33ca 100644 --- a/Marlin/src/config/examples/Velleman/K8400/Dual-head/Configuration.h +++ b/Marlin/src/config/examples/Velleman/K8400/Dual-head/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/Wanhao/Duplicator 6/Configuration.h b/Marlin/src/config/examples/Wanhao/Duplicator 6/Configuration.h index e742e2128c..f81e677114 100644 --- a/Marlin/src/config/examples/Wanhao/Duplicator 6/Configuration.h +++ b/Marlin/src/config/examples/Wanhao/Duplicator 6/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/adafruit/ST7565/Configuration.h b/Marlin/src/config/examples/adafruit/ST7565/Configuration.h index 5453a8ebdf..e01bd065ca 100644 --- a/Marlin/src/config/examples/adafruit/ST7565/Configuration.h +++ b/Marlin/src/config/examples/adafruit/ST7565/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/delta/FLSUN/auto_calibrate/Configuration.h b/Marlin/src/config/examples/delta/FLSUN/auto_calibrate/Configuration.h index d46a1a5ede..f623b8a14e 100644 --- a/Marlin/src/config/examples/delta/FLSUN/auto_calibrate/Configuration.h +++ b/Marlin/src/config/examples/delta/FLSUN/auto_calibrate/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/delta/FLSUN/kossel_mini/Configuration.h b/Marlin/src/config/examples/delta/FLSUN/kossel_mini/Configuration.h index ca2baea15f..316494b72e 100644 --- a/Marlin/src/config/examples/delta/FLSUN/kossel_mini/Configuration.h +++ b/Marlin/src/config/examples/delta/FLSUN/kossel_mini/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/delta/generic/Configuration.h b/Marlin/src/config/examples/delta/generic/Configuration.h index 6f518db874..4c53d21072 100644 --- a/Marlin/src/config/examples/delta/generic/Configuration.h +++ b/Marlin/src/config/examples/delta/generic/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/delta/kossel_mini/Configuration.h b/Marlin/src/config/examples/delta/kossel_mini/Configuration.h index 9a0251577f..b48db2a4e1 100644 --- a/Marlin/src/config/examples/delta/kossel_mini/Configuration.h +++ b/Marlin/src/config/examples/delta/kossel_mini/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/delta/kossel_pro/Configuration.h b/Marlin/src/config/examples/delta/kossel_pro/Configuration.h index 0d7e157681..84695b0a64 100644 --- a/Marlin/src/config/examples/delta/kossel_pro/Configuration.h +++ b/Marlin/src/config/examples/delta/kossel_pro/Configuration.h @@ -257,7 +257,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/delta/kossel_xl/Configuration.h b/Marlin/src/config/examples/delta/kossel_xl/Configuration.h index 27c6b72ba5..4fb53477dc 100644 --- a/Marlin/src/config/examples/delta/kossel_xl/Configuration.h +++ b/Marlin/src/config/examples/delta/kossel_xl/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/gCreate/gMax1.5+/Configuration.h b/Marlin/src/config/examples/gCreate/gMax1.5+/Configuration.h index 2c00bed65b..bca4e3a2a3 100644 --- a/Marlin/src/config/examples/gCreate/gMax1.5+/Configuration.h +++ b/Marlin/src/config/examples/gCreate/gMax1.5+/Configuration.h @@ -258,7 +258,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/makibox/Configuration.h b/Marlin/src/config/examples/makibox/Configuration.h index 91be05ed5a..e3dd1c2b71 100644 --- a/Marlin/src/config/examples/makibox/Configuration.h +++ b/Marlin/src/config/examples/makibox/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/stm32f103ret6/Configuration.h b/Marlin/src/config/examples/stm32f103ret6/Configuration.h index 431c9cb70d..82b72cead3 100644 --- a/Marlin/src/config/examples/stm32f103ret6/Configuration.h +++ b/Marlin/src/config/examples/stm32f103ret6/Configuration.h @@ -234,7 +234,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/tvrrug/Round2/Configuration.h b/Marlin/src/config/examples/tvrrug/Round2/Configuration.h index 05633fb367..6e3c385424 100644 --- a/Marlin/src/config/examples/tvrrug/Round2/Configuration.h +++ b/Marlin/src/config/examples/tvrrug/Round2/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/config/examples/wt150/Configuration.h b/Marlin/src/config/examples/wt150/Configuration.h index 1519b1d461..69f6815b3d 100644 --- a/Marlin/src/config/examples/wt150/Configuration.h +++ b/Marlin/src/config/examples/wt150/Configuration.h @@ -253,7 +253,7 @@ * 2 : 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) * 3 : Mendel-parts thermistor (4.7k pullup) * 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! - * 5 : 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup) + * 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan & J-Head) (4.7k pullup) * 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) * 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) * 71 : 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup) diff --git a/Marlin/src/module/thermistor/thermistor_5.h b/Marlin/src/module/thermistor/thermistor_5.h index 07f68feb2b..8a5b9fd1a3 100644 --- a/Marlin/src/module/thermistor/thermistor_5.h +++ b/Marlin/src/module/thermistor/thermistor_5.h @@ -21,7 +21,7 @@ */ // 100k ParCan thermistor (104GT-2) -// ATC Semitec 104GT-2 (Used in ParCan) +// ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan) // Verified by linagee. Source: http://shop.arcol.hu/static/datasheets/thermistors.pdf // Calculated using 4.7kohm pullup, voltage divider math, and manufacturer provided temp/resistance const short temptable_5[][2] PROGMEM = {