Browse Source

RUMBA has 3 E plugs

vanilla_fb_2.0.x
Scott Lahteine 5 years ago
parent
commit
4f55723527
  1. 5
      Marlin/src/module/temperature.cpp

5
Marlin/src/module/temperature.cpp

@ -1660,10 +1660,9 @@ void Temperature::init() {
#endif
#if MB(RUMBA)
// Disable RUMBA JTAG in case the thermocouple extension is plugged on top of JTAG connector
#define _AD(N) ANY(HEATER_##N##_USES_AD595, HEATER_##N##_USES_AD8495)
#if _AD(0) || _AD(1) || _AD(2) /* RUMBA has 3 E plugs // || _AD(3) || _AD(4) || _AD(5) || _AD(6) || _AD(7) */ \
|| _AD(BED) || _AD(CHAMBER)
// Disable RUMBA JTAG in case the thermocouple extension is plugged on top of JTAG connector
#if _AD(0) || _AD(1) || _AD(2) || _AD(BED) || _AD(CHAMBER)
MCUCR = _BV(JTD);
MCUCR = _BV(JTD);
#endif