Browse Source

Allow Thermistor #12 to be used on hotends also

//100k 0603 SMD Vishay NTCS0603E3104FXT (4.7k pullup) (calibrated for Makibox hot bed)

Caveat Emptor —- 
I’m not sure that this really makes sense,
but why keep someone from using it?
pull/1/head
Richard Wackerbarth 9 years ago
parent
commit
4f314afaf0
  1. 2
      Marlin/thermistortables.h

2
Marlin/thermistortables.h

@ -957,7 +957,7 @@ const short temptable_60[][2] PROGMEM = {
{1008 * OVERSAMPLENR, 0},
};
#endif
#if (THERMISTORBED == 12)
#if (THERMISTORHEATER_0 == 12) || (THERMISTORHEATER_1 == 12) || (THERMISTORHEATER_2 == 12) || (THERMISTORHEATER_3 == 12) || (THERMISTORBED == 12)
//100k 0603 SMD Vishay NTCS0603E3104FXT (4.7k pullup) (calibrated for Makibox hot bed)
const short temptable_12[][2] PROGMEM = {
{35 * OVERSAMPLENR, 180}, //top rating 180C

Loading…
Cancel
Save