@ -406,7 +406,7 @@ void ChironTFT::CheckHeaters() { |
|
|
|
|
|
|
|
// Update panel with hotend heater status
|
|
|
|
if (hotend_state != AC_heater_temp_reached) { |
|
|
|
if (WITHIN(getActualTemp_celsius(E0) - getTargetTemp_celsius(E0), -1, 1)) { |
|
|
|
if (WITHIN(getActualTemp_celsius(E0) - getTargetTemp_celsius(E0), -(TEMP_WINDOW), TEMP_WINDOW)) { |
|
|
|
SendtoTFTLN(AC_msg_nozzle_heating_done); |
|
|
|
hotend_state = AC_heater_temp_reached; |
|
|
|
} |
|
|
@ -414,7 +414,7 @@ void ChironTFT::CheckHeaters() { |
|
|
|
|
|
|
|
// Update panel with bed heater status
|
|
|
|
if (hotbed_state != AC_heater_temp_reached) { |
|
|
|
if (WITHIN(getActualTemp_celsius(BED) - getTargetTemp_celsius(BED), -0.5, 0.5)) { |
|
|
|
if (WITHIN(getActualTemp_celsius(BED) - getTargetTemp_celsius(BED), -(TEMP_BED_WINDOW), TEMP_BED_WINDOW)) { |
|
|
|
SendtoTFTLN(AC_msg_bed_heating_done); |
|
|
|
hotbed_state = AC_heater_temp_reached; |
|
|
|
} |
|
|
|