From 49e83dd7c81cffef7462a0a53a70a125562de83a Mon Sep 17 00:00:00 2001 From: InsanityAutomation <38436470+InsanityAutomation@users.noreply.github.com> Date: Sat, 25 May 2019 22:56:47 -0400 Subject: [PATCH] BLTouch V3.1 changes (#14104) --- Marlin/Configuration.h | 68 ++++++++++++++++-- Marlin/src/Marlin.cpp | 2 +- Marlin/src/feature/bltouch.cpp | 72 ++++++++++++++++--- Marlin/src/feature/bltouch.h | 9 ++- Marlin/src/inc/SanityCheck.h | 4 +- Marlin/src/lcd/language/language_en.h | 27 ++++--- Marlin/src/lcd/menu/menu_advanced.cpp | 14 ---- Marlin/src/lcd/menu/menu_configuration.cpp | 29 +++++++- Marlin/src/module/configuration_store.cpp | 44 +++++++++++- config/default/Configuration.h | 68 ++++++++++++++++-- .../examples/3DFabXYZ/Migbot/Configuration.h | 68 ++++++++++++++++-- .../AlephObjects/TAZ4/Configuration.h | 68 ++++++++++++++++-- .../AliExpress/CL-260/Configuration.h | 68 ++++++++++++++++-- .../AliExpress/UM2pExt/Configuration.h | 68 ++++++++++++++++-- config/examples/Anet/A2/Configuration.h | 68 ++++++++++++++++-- config/examples/Anet/A2plus/Configuration.h | 68 ++++++++++++++++-- config/examples/Anet/A6/Configuration.h | 68 ++++++++++++++++-- config/examples/Anet/A8/Configuration.h | 68 ++++++++++++++++-- config/examples/Anet/A8plus/Configuration.h | 68 ++++++++++++++++-- config/examples/Anet/E16/Configuration.h | 68 ++++++++++++++++-- config/examples/AnyCubic/i3/Configuration.h | 68 ++++++++++++++++-- config/examples/ArmEd/Configuration.h | 68 ++++++++++++++++-- config/examples/Azteeg/X5GT/Configuration.h | 68 ++++++++++++++++-- .../BIBO/TouchX/cyclops/Configuration.h | 68 ++++++++++++++++-- .../BIBO/TouchX/default/Configuration.h | 68 ++++++++++++++++-- config/examples/BQ/Hephestos/Configuration.h | 68 ++++++++++++++++-- .../examples/BQ/Hephestos_2/Configuration.h | 68 ++++++++++++++++-- config/examples/BQ/WITBOX/Configuration.h | 68 ++++++++++++++++-- config/examples/Cartesio/Configuration.h | 68 ++++++++++++++++-- .../examples/Creality/CR-10/Configuration.h | 68 ++++++++++++++++-- .../examples/Creality/CR-10S/Configuration.h | 68 ++++++++++++++++-- .../Creality/CR-10_5S/Configuration.h | 68 ++++++++++++++++-- .../Creality/CR-10mini/Configuration.h | 68 ++++++++++++++++-- config/examples/Creality/CR-8/Configuration.h | 68 ++++++++++++++++-- .../examples/Creality/Ender-2/Configuration.h | 68 ++++++++++++++++-- .../examples/Creality/Ender-3/Configuration.h | 68 ++++++++++++++++-- .../examples/Creality/Ender-4/Configuration.h | 68 ++++++++++++++++-- config/examples/Einstart-S/Configuration.h | 68 ++++++++++++++++-- config/examples/Felix/Configuration.h | 68 ++++++++++++++++-- config/examples/Felix/DUAL/Configuration.h | 68 ++++++++++++++++-- .../FlashForge/CreatorPro/Configuration.h | 68 ++++++++++++++++-- .../FolgerTech/i3-2020/Configuration.h | 68 ++++++++++++++++-- .../examples/Formbot/Raptor/Configuration.h | 68 ++++++++++++++++-- .../examples/Formbot/T_Rex_2+/Configuration.h | 68 ++++++++++++++++-- .../examples/Formbot/T_Rex_3/Configuration.h | 68 ++++++++++++++++-- config/examples/Geeetech/A10M/Configuration.h | 69 ++++++++++++++++-- config/examples/Geeetech/A20M/Configuration.h | 69 ++++++++++++++++-- .../examples/Geeetech/GT2560/Configuration.h | 68 ++++++++++++++++-- .../Geeetech/MeCreator2/Configuration.h | 68 ++++++++++++++++-- .../Prusa i3 Pro B/bltouch/Configuration.h | 68 ++++++++++++++++-- .../Prusa i3 Pro B/noprobe/Configuration.h | 68 ++++++++++++++++-- .../Geeetech/Prusa i3 Pro C/Configuration.h | 68 ++++++++++++++++-- .../Geeetech/Prusa i3 Pro W/Configuration.h | 68 ++++++++++++++++-- .../examples/Infitary/i3-M508/Configuration.h | 68 ++++++++++++++++-- config/examples/JGAurora/A5/Configuration.h | 68 ++++++++++++++++-- config/examples/MakerParts/Configuration.h | 68 ++++++++++++++++-- config/examples/Malyan/M150/Configuration.h | 68 ++++++++++++++++-- config/examples/Malyan/M200/Configuration.h | 68 ++++++++++++++++-- .../Micromake/C1/basic/Configuration.h | 68 ++++++++++++++++-- .../Micromake/C1/enhanced/Configuration.h | 68 ++++++++++++++++-- config/examples/Mks/Robin/Configuration.h | 68 ++++++++++++++++-- config/examples/Mks/Sbase/Configuration.h | 68 ++++++++++++++++-- .../Printrbot/PrintrboardG2/Configuration.h | 68 ++++++++++++++++-- .../examples/RapideLite/RL200/Configuration.h | 68 ++++++++++++++++-- .../examples/RepRapPro/Huxley/Configuration.h | 68 ++++++++++++++++-- .../RepRapWorld/Megatronics/Configuration.h | 68 ++++++++++++++++-- config/examples/RigidBot/Configuration.h | 68 ++++++++++++++++-- config/examples/SCARA/Configuration.h | 68 ++++++++++++++++-- .../STM32/Black_STM32F407VET6/Configuration.h | 68 ++++++++++++++++-- .../examples/STM32/STM32F10/Configuration.h | 68 ++++++++++++++++-- config/examples/STM32/STM32F4/Configuration.h | 68 ++++++++++++++++-- .../STM32/stm32f103ret6/Configuration.h | 68 ++++++++++++++++-- config/examples/Sanguinololu/Configuration.h | 68 ++++++++++++++++-- config/examples/TheBorg/Configuration.h | 68 ++++++++++++++++-- config/examples/TinyBoy2/Configuration.h | 68 ++++++++++++++++-- config/examples/Tronxy/X1/Configuration.h | 68 ++++++++++++++++-- config/examples/Tronxy/X3A/Configuration.h | 68 ++++++++++++++++-- config/examples/Tronxy/X5S-2E/Configuration.h | 68 ++++++++++++++++-- config/examples/Tronxy/X5S/Configuration.h | 68 ++++++++++++++++-- config/examples/Tronxy/XY100/Configuration.h | 68 ++++++++++++++++-- .../UltiMachine/Archim1/Configuration.h | 68 ++++++++++++++++-- .../UltiMachine/Archim2/Configuration.h | 68 ++++++++++++++++-- config/examples/VORONDesign/Configuration.h | 68 ++++++++++++++++-- .../examples/Velleman/K8200/Configuration.h | 68 ++++++++++++++++-- .../examples/Velleman/K8400/Configuration.h | 68 ++++++++++++++++-- .../Velleman/K8400/Dual-head/Configuration.h | 68 ++++++++++++++++-- .../examples/WASP/PowerWASP/Configuration.h | 68 ++++++++++++++++-- .../Wanhao/Duplicator 6/Configuration.h | 68 ++++++++++++++++-- .../examples/adafruit/ST7565/Configuration.h | 68 ++++++++++++++++-- .../delta/Anycubic/Kossel/Configuration.h | 68 ++++++++++++++++-- .../FLSUN/auto_calibrate/Configuration.h | 68 ++++++++++++++++-- .../delta/FLSUN/kossel/Configuration.h | 68 ++++++++++++++++-- .../delta/FLSUN/kossel_mini/Configuration.h | 68 ++++++++++++++++-- .../Geeetech/Rostock 301/Configuration.h | 68 ++++++++++++++++-- .../delta/Hatchbox_Alpha/Configuration.h | 68 ++++++++++++++++-- .../examples/delta/MKS/SBASE/Configuration.h | 68 ++++++++++++++++-- config/examples/delta/generic/Configuration.h | 68 ++++++++++++++++-- .../delta/kossel_mini/Configuration.h | 68 ++++++++++++++++-- .../examples/delta/kossel_pro/Configuration.h | 68 ++++++++++++++++-- .../examples/delta/kossel_xl/Configuration.h | 68 ++++++++++++++++-- config/examples/makibox/Configuration.h | 68 ++++++++++++++++-- config/examples/tvrrug/Round2/Configuration.h | 68 ++++++++++++++++-- config/examples/wt150/Configuration.h | 68 ++++++++++++++++-- 103 files changed, 6050 insertions(+), 613 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index 4e4393ae8c..d0ccf20148 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/Marlin/src/Marlin.cpp b/Marlin/src/Marlin.cpp index 6f9e527832..c1f87f55dc 100644 --- a/Marlin/src/Marlin.cpp +++ b/Marlin/src/Marlin.cpp @@ -1058,7 +1058,7 @@ void setup() { #endif #if ENABLED(BLTOUCH) - bltouch.init(); + bltouch.init(/*set_voltage=*/true); #endif #if ENABLED(I2C_POSITION_ENCODERS) diff --git a/Marlin/src/feature/bltouch.cpp b/Marlin/src/feature/bltouch.cpp index 2b0b73bc95..abaeb153ee 100644 --- a/Marlin/src/feature/bltouch.cpp +++ b/Marlin/src/feature/bltouch.cpp @@ -28,6 +28,8 @@ BLTouch bltouch; +bool BLTouch::last_written_mode; // Initialized by settings.load, 0 = Open Drain; 1 = 5V Drain + #include "../module/servo.h" void stop(); @@ -38,21 +40,53 @@ void stop(); bool BLTouch::command(const BLTCommand cmd, const millis_t &ms) { if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPAIR("BLTouch Command :", cmd); MOVE_SERVO(Z_PROBE_SERVO_NR, cmd); - safe_delay(MAX(ms, BLTOUCH_DELAY)); // BLTOUCH_DELAY is also the *minimum* delay + safe_delay(MAX(ms, (uint32_t)BLTOUCH_DELAY)); // BLTOUCH_DELAY is also the *minimum* delay return triggered(); } -void BLTouch::init() { - // This is called by marlin.cpp on initialization - // SET_5V_MODE (if enabled). OD_MODE is the default on power on. - // This mode will stay active until manual SET_OD_MODE or power cycle - #if ENABLED(BLTOUCH_FORCE_5V_MODE) - _set_5V_mode(); // Set 5V mode if explicitely demanded (V3 upwards) +// Init the class and device. Call from setup(). +void BLTouch::init(const bool set_voltage/*=false*/) { + // Voltage Setting (if enabled). At every Marlin initialization: + // BLTOUCH < V3.0 and clones: This will be ignored by the probe + // BLTOUCH V3.0: SET_5V_MODE or SET_OD_MODE (if enabled). + // OD_MODE is the default on power on, but setting it does not hurt + // This mode will stay active until manual SET_OD_MODE or power cycle + // BLTOUCH V3.1: SET_5V_MODE or SET_OD_MODE (if enabled). + // At power on, the probe will default to the eeprom settings configured by the user + #if ENABLED(BLTOUCH_FORCE_MODE_SET) + + constexpr bool should_set = true; + + #else + + if (DEBUGGING(LEVELING)) { + DEBUG_ECHOLNPAIR("last_written_mode - ", (int)last_written_mode); + DEBUG_ECHOLNPGM("config mode - " + #if ENABLED(BLTOUCH_SET_5V_MODE) + "BLTOUCH_SET_5V_MODE" + #else + "OD" + #endif + ); + } + + const bool should_set = last_written_mode != (false + #if ENABLED(BLTOUCH_SET_5V_MODE) + || true + #endif + ); + #endif + + if (should_set && set_voltage) + mode_conv_proc((false + #if ENABLED(BLTOUCH_SET_5V_MODE) + || true + #endif + )); + _reset(); _stow(); - // There really should be no alarm outstanding now, and no triggered condition. But if there is, - // there is no need to worry people here on init right at the start of the printer. } void BLTouch::clear() { @@ -97,6 +131,11 @@ bool BLTouch::deploy_proc() { } } + // One of the recommended ANTClabs ways to probe, using SW MODE + #if ENABLED(BLTOUCH_FORCE_SW_MODE) + _set_SW_mode(); + #endif + // Now the probe is ready to issue a 10ms pulse when the pin goes up. // The trigger STOW (see motion.cpp for example) will pull up the probes pin as soon as the pulse // is registered. @@ -159,4 +198,19 @@ bool BLTouch::status_proc() { return !tr; } +void BLTouch::mode_conv_proc(const bool M5V) { + /** + * BLTOUCH pre V3.0 and clones: No reaction at all to this sequence apart from a DEPLOY -> STOW + * BLTOUCH V3.0: This will set the mode (twice) and sadly, a STOW is needed at the end, because of the deploy + * BLTOUCH V3.1: This will set the mode and store it in the eeprom. The STOW is not needed but does not hurt + */ + if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPAIR("BLTouch Set Mode - ", (int)M5V); + _deploy(); + if (M5V) _set_5V_mode(); else _set_OD_mode(); + _mode_store(); + if (M5V) _set_5V_mode(); else _set_OD_mode(); + _stow(); + last_written_mode = M5V; +} + #endif // BLTOUCH diff --git a/Marlin/src/feature/bltouch.h b/Marlin/src/feature/bltouch.h index 25a1191935..b349c61804 100644 --- a/Marlin/src/feature/bltouch.h +++ b/Marlin/src/feature/bltouch.h @@ -67,8 +67,8 @@ typedef unsigned char BLTCommand; class BLTouch { public: - static bool triggered(); // used by menu_advanced.cpp - static void init(); // used by main.cpp + static void init(const bool set_voltage=false); + static bool last_written_mode; // Initialized by settings.load, 0 = Open Drain; 1 = 5V Drain // DEPLOY and STOW are wrapped for error handling - these are used by homing and by probing FORCE_INLINE static bool deploy() { return deploy_proc(); } @@ -90,15 +90,20 @@ public: FORCE_INLINE static void _deploy() { command(BLTOUCH_DEPLOY, BLTOUCH_DEPLOY_DELAY); } FORCE_INLINE static void _stow() { command(BLTOUCH_STOW, BLTOUCH_STOW_DELAY); } + FORCE_INLINE static void mode_conv_5V() { mode_conv_proc(true); } + FORCE_INLINE static void mode_conv_OD() { mode_conv_proc(false); } + private: FORCE_INLINE static bool _deploy_query_alarm() { return command(BLTOUCH_DEPLOY, BLTOUCH_DEPLOY_DELAY); } FORCE_INLINE static bool _stow_query_alarm() { return command(BLTOUCH_STOW, BLTOUCH_STOW_DELAY); } static void clear(); static bool command(const BLTCommand cmd, const millis_t &ms); + static bool triggered(); static bool deploy_proc(); static bool stow_proc(); static bool status_proc(); + static void mode_conv_proc(const bool M5V); }; // Deploy/stow angles for use by servo.cpp / servo.h diff --git a/Marlin/src/inc/SanityCheck.h b/Marlin/src/inc/SanityCheck.h index 3409cf35ad..5bea38d9eb 100644 --- a/Marlin/src/inc/SanityCheck.h +++ b/Marlin/src/inc/SanityCheck.h @@ -1028,8 +1028,8 @@ static_assert(Y_MAX_LENGTH >= Y_BED_SIZE, "Movement bounds (Y_MIN_POS, Y_MAX_POS #if ENABLED(BLTOUCH) #if BLTOUCH_DELAY < 200 #error "BLTOUCH_DELAY less than 200 is unsafe and is not supported." - #elif DISABLED(BLTOUCH_FORCE_5V_MODE) && NONE(ENDSTOPPULLUPS, ENDSTOPPULLUP_ZMIN, ENDSTOPPULLUP_ZMIN_PROBE) - #error "BLTOUCH without BLTOUCH_FORCE_5V_MODE requires ENDSTOPPULLUPS, ENDSTOPPULLUP_ZMIN or ENDSTOPPULLUP_ZMIN_PROBE." + #elif DISABLED(BLTOUCH_SET_5V_MODE) && NONE(ENDSTOPPULLUPS, ENDSTOPPULLUP_ZMIN, ENDSTOPPULLUP_ZMIN_PROBE) + #error "BLTOUCH without BLTOUCH_SET_5V_MODE requires ENDSTOPPULLUPS, ENDSTOPPULLUP_ZMIN or ENDSTOPPULLUP_ZMIN_PROBE." #endif #endif diff --git a/Marlin/src/lcd/language/language_en.h b/Marlin/src/lcd/language/language_en.h index 939c03a39d..aa4770bfd5 100644 --- a/Marlin/src/lcd/language/language_en.h +++ b/Marlin/src/lcd/language/language_en.h @@ -901,28 +901,37 @@ #define MSG_BLTOUCH _UxGT("BLTouch") #endif #ifndef MSG_BLTOUCH_SELFTEST - #define MSG_BLTOUCH_SELFTEST _UxGT("BLTouch Self-Test") + #define MSG_BLTOUCH_SELFTEST _UxGT("Cmd: Self-Test") #endif #ifndef MSG_BLTOUCH_RESET - #define MSG_BLTOUCH_RESET _UxGT("Reset BLTouch") + #define MSG_BLTOUCH_RESET _UxGT("Cmd: Reset") +#endif +#ifndef MSG_BLTOUCH_STOW + #define MSG_BLTOUCH_STOW _UxGT("Cmd: Stow") #endif #ifndef MSG_BLTOUCH_DEPLOY - #define MSG_BLTOUCH_DEPLOY _UxGT("Deploy BLTouch") + #define MSG_BLTOUCH_DEPLOY _UxGT("Cmd: Deploy") #endif #ifndef MSG_BLTOUCH_SW_MODE - #define MSG_BLTOUCH_SW_MODE _UxGT("BLTouch SW Mode") + #define MSG_BLTOUCH_SW_MODE _UxGT("Cmd: SW-Mode") #endif #ifndef MSG_BLTOUCH_5V_MODE - #define MSG_BLTOUCH_5V_MODE _UxGT("BLTouch 5V Mode") + #define MSG_BLTOUCH_5V_MODE _UxGT("Cmd: 5V-Mode") #endif #ifndef MSG_BLTOUCH_OD_MODE - #define MSG_BLTOUCH_OD_MODE _UxGT("BLTouch OD Mode") + #define MSG_BLTOUCH_OD_MODE _UxGT("Cmd: OD-Mode") #endif #ifndef MSG_BLTOUCH_MODE_STORE - #define MSG_BLTOUCH_MODE_STORE _UxGT("BLTouch Mode Store") + #define MSG_BLTOUCH_MODE_STORE _UxGT("Cmd: Mode-Store") #endif -#ifndef MSG_BLTOUCH_STOW - #define MSG_BLTOUCH_STOW _UxGT("Stow BLTouch") +#ifndef MSG_BLTOUCH_MODE_STORE_5V + #define MSG_BLTOUCH_MODE_STORE_5V _UxGT("Set BLTouch to 5V") +#endif +#ifndef MSG_BLTOUCH_MODE_STORE_OD + #define MSG_BLTOUCH_MODE_STORE_OD _UxGT("Set BLTouch to OD") +#endif +#ifndef MSG_BLTOUCH_MODE_ECHO + #define MSG_BLTOUCH_MODE_ECHO _UxGT("Report Drain") #endif #ifndef MSG_MANUAL_DEPLOY #define MSG_MANUAL_DEPLOY _UxGT("Deploy Z-Probe") diff --git a/Marlin/src/lcd/menu/menu_advanced.cpp b/Marlin/src/lcd/menu/menu_advanced.cpp index f17d6b3097..df873fc06d 100644 --- a/Marlin/src/lcd/menu/menu_advanced.cpp +++ b/Marlin/src/lcd/menu/menu_advanced.cpp @@ -39,11 +39,6 @@ #include "../../module/probe.h" #endif -#if ENABLED(BLTOUCH) - #include "../../module/endstops.h" - #include "../../feature/bltouch.h" -#endif - #if ENABLED(PIDTEMP) #include "../../module/temperature.h" #endif @@ -683,15 +678,6 @@ void menu_advanced_settings() { MENU_ITEM_EDIT(bool, MSG_ENDSTOP_ABORT, &planner.abort_on_endstop_hit); #endif - // - // BLTouch Self-Test and Reset - // - #if ENABLED(BLTOUCH) - MENU_ITEM(function, MSG_BLTOUCH_SELFTEST, []{ bltouch._selftest(); ui.refresh(); }); - if (!endstops.z_probe_enabled && bltouch.triggered()) - MENU_ITEM(function, MSG_BLTOUCH_RESET, []{ bltouch._reset(); ui.refresh(); }); - #endif - #if ENABLED(SD_FIRMWARE_UPDATE) bool sd_update_state = settings.sd_update_status(); MENU_ITEM_EDIT_CALLBACK(bool, MSG_SD_UPDATE, &sd_update_state, []{ diff --git a/Marlin/src/lcd/menu/menu_configuration.cpp b/Marlin/src/lcd/menu/menu_configuration.cpp index 3dc617850a..7b65e6ba98 100644 --- a/Marlin/src/lcd/menu/menu_configuration.cpp +++ b/Marlin/src/lcd/menu/menu_configuration.cpp @@ -172,6 +172,24 @@ static void lcd_factory_settings() { #if ENABLED(BLTOUCH) + #if ENABLED(BLTOUCH_LCD_VOLTAGE_MENU) + void bltouch_report() { + SERIAL_ECHOLNPAIR("EEPROM Last BLTouch Mode - ", (int)bltouch.last_written_mode); + SERIAL_ECHOLNPGM("Configuration BLTouch Mode - " + #if ENABLED(BLTOUCH_SET_5V_MODE) + "5V" + #else + "OD" + #endif + ); + char mess[21]; + strcpy_P(mess, PSTR("BLTouch Mode - ")); + sprintf_P(&mess[15], bltouch.last_written_mode ? PSTR("5V") : PSTR("OD")); + ui.set_status(mess); + ui.return_to_status(); + } + #endif + void menu_bltouch() { START_MENU(); MENU_BACK(MSG_CONFIGURATION); @@ -180,9 +198,14 @@ static void lcd_factory_settings() { MENU_ITEM(function, MSG_BLTOUCH_DEPLOY, bltouch._deploy); MENU_ITEM(function, MSG_BLTOUCH_STOW, bltouch._stow); MENU_ITEM(function, MSG_BLTOUCH_SW_MODE, bltouch._set_SW_mode); - MENU_ITEM(function, MSG_BLTOUCH_5V_MODE, bltouch._set_5V_mode); - MENU_ITEM(function, MSG_BLTOUCH_OD_MODE, bltouch._set_OD_mode); - MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE, bltouch._mode_store); + #if ENABLED(BLTOUCH_LCD_VOLTAGE_MENU) + MENU_ITEM(function, MSG_BLTOUCH_5V_MODE, bltouch._set_5V_mode); + MENU_ITEM(function, MSG_BLTOUCH_OD_MODE, bltouch._set_OD_mode); + MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE, bltouch._mode_store); + MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE_5V, bltouch.mode_conv_5V); + MENU_ITEM(function, MSG_BLTOUCH_MODE_STORE_OD, bltouch.mode_conv_OD); + MENU_ITEM(function, MSG_BLTOUCH_MODE_ECHO, bltouch_report); + #endif END_MENU(); } diff --git a/Marlin/src/module/configuration_store.cpp b/Marlin/src/module/configuration_store.cpp index d2e8418fe2..df9f62fce8 100644 --- a/Marlin/src/module/configuration_store.cpp +++ b/Marlin/src/module/configuration_store.cpp @@ -37,7 +37,7 @@ */ // Change EEPROM version if the structure changes -#define EEPROM_VERSION "V66" +#define EEPROM_VERSION "V67" #define EEPROM_OFFSET 100 // Check the integrity of data offsets. @@ -109,6 +109,10 @@ extern float saved_extruder_advance_K[EXTRUDERS]; void M217_report(const bool eeprom); #endif +#if ENABLED(BLTOUCH) + #include "../feature/bltouch.h" +#endif + #if HAS_TRINAMIC #include "stepper_indirection.h" #include "../feature/tmc_util.h" @@ -206,6 +210,11 @@ typedef struct SettingsDataStruct { // uint16_t servo_angles[EEPROM_NUM_SERVOS][2]; // M281 P L U + // + // BLTOUCH + // + bool bltouch_last_written_mode; + // // DELTA / [XYZ]_DUAL_ENDSTOPS // @@ -700,6 +709,19 @@ void MarlinSettings::postprocess() { EEPROM_WRITE(servo_angles); } + // + // BLTOUCH + // + { + _FIELD_TEST(bltouch_last_written_mode); + #if ENABLED(BLTOUCH) + const bool &bltouch_last_written_mode = bltouch.last_written_mode; + #else + constexpr bool bltouch_last_written_mode = false; + #endif + EEPROM_WRITE(bltouch_last_written_mode); + } + // // DELTA Geometry or Dual Endstops offsets // @@ -1488,6 +1510,19 @@ void MarlinSettings::postprocess() { EEPROM_READ(servo_angles_arr); } + // + // BLTOUCH + // + { + _FIELD_TEST(bltouch_last_written_mode); + #if ENABLED(BLTOUCH) + bool &bltouch_last_written_mode = bltouch.last_written_mode; + #else + bool bltouch_last_written_mode; + #endif + EEPROM_READ(bltouch_last_written_mode); + } + // // DELTA Geometry or Dual Endstops offsets // @@ -2313,6 +2348,13 @@ void MarlinSettings::reset() { COPY(servo_angles, base_servo_angles); #endif + // + // BLTOUCH + // + //#if ENABLED(BLTOUCH) + // bltouch.last_written_mode; + //#endif + // // Endstop Adjustments // diff --git a/config/default/Configuration.h b/config/default/Configuration.h index 4e4393ae8c..d0ccf20148 100644 --- a/config/default/Configuration.h +++ b/config/default/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/3DFabXYZ/Migbot/Configuration.h b/config/examples/3DFabXYZ/Migbot/Configuration.h index e04d06cf52..7989f37cd6 100644 --- a/config/examples/3DFabXYZ/Migbot/Configuration.h +++ b/config/examples/3DFabXYZ/Migbot/Configuration.h @@ -834,15 +834,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/AlephObjects/TAZ4/Configuration.h b/config/examples/AlephObjects/TAZ4/Configuration.h index 2df48bc0c0..33d2b42ce8 100644 --- a/config/examples/AlephObjects/TAZ4/Configuration.h +++ b/config/examples/AlephObjects/TAZ4/Configuration.h @@ -848,15 +848,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/AliExpress/CL-260/Configuration.h b/config/examples/AliExpress/CL-260/Configuration.h index 2d7a789f00..0605526f74 100644 --- a/config/examples/AliExpress/CL-260/Configuration.h +++ b/config/examples/AliExpress/CL-260/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/AliExpress/UM2pExt/Configuration.h b/config/examples/AliExpress/UM2pExt/Configuration.h index 96eff9c21b..f4423157ae 100644 --- a/config/examples/AliExpress/UM2pExt/Configuration.h +++ b/config/examples/AliExpress/UM2pExt/Configuration.h @@ -839,15 +839,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Anet/A2/Configuration.h b/config/examples/Anet/A2/Configuration.h index 02f701dcb5..eaaf073e16 100644 --- a/config/examples/Anet/A2/Configuration.h +++ b/config/examples/Anet/A2/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Anet/A2plus/Configuration.h b/config/examples/Anet/A2plus/Configuration.h index 49a4ba2f17..ca22d5eeb7 100644 --- a/config/examples/Anet/A2plus/Configuration.h +++ b/config/examples/Anet/A2plus/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Anet/A6/Configuration.h b/config/examples/Anet/A6/Configuration.h index 1f7b2b87ba..35986136c4 100644 --- a/config/examples/Anet/A6/Configuration.h +++ b/config/examples/Anet/A6/Configuration.h @@ -875,15 +875,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Anet/A8/Configuration.h b/config/examples/Anet/A8/Configuration.h index 72b509cf3b..21b76caac5 100644 --- a/config/examples/Anet/A8/Configuration.h +++ b/config/examples/Anet/A8/Configuration.h @@ -841,15 +841,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Anet/A8plus/Configuration.h b/config/examples/Anet/A8plus/Configuration.h index 4b39c71103..c40b6f7827 100644 --- a/config/examples/Anet/A8plus/Configuration.h +++ b/config/examples/Anet/A8plus/Configuration.h @@ -839,15 +839,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Anet/E16/Configuration.h b/config/examples/Anet/E16/Configuration.h index 896514857a..a08d2248c8 100644 --- a/config/examples/Anet/E16/Configuration.h +++ b/config/examples/Anet/E16/Configuration.h @@ -840,15 +840,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/AnyCubic/i3/Configuration.h b/config/examples/AnyCubic/i3/Configuration.h index 4cf8808346..70cfd08dd2 100644 --- a/config/examples/AnyCubic/i3/Configuration.h +++ b/config/examples/AnyCubic/i3/Configuration.h @@ -838,15 +838,71 @@ */ #define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/ArmEd/Configuration.h b/config/examples/ArmEd/Configuration.h index 41fb08b9fc..5e1c2ba6fe 100644 --- a/config/examples/ArmEd/Configuration.h +++ b/config/examples/ArmEd/Configuration.h @@ -829,15 +829,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Azteeg/X5GT/Configuration.h b/config/examples/Azteeg/X5GT/Configuration.h index 16505588a5..f916b973ba 100644 --- a/config/examples/Azteeg/X5GT/Configuration.h +++ b/config/examples/Azteeg/X5GT/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/BIBO/TouchX/cyclops/Configuration.h b/config/examples/BIBO/TouchX/cyclops/Configuration.h index 2e45cb2ef0..cd8e443771 100644 --- a/config/examples/BIBO/TouchX/cyclops/Configuration.h +++ b/config/examples/BIBO/TouchX/cyclops/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/BIBO/TouchX/default/Configuration.h b/config/examples/BIBO/TouchX/default/Configuration.h index 49bf0753cc..995e50f81e 100644 --- a/config/examples/BIBO/TouchX/default/Configuration.h +++ b/config/examples/BIBO/TouchX/default/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/BQ/Hephestos/Configuration.h b/config/examples/BQ/Hephestos/Configuration.h index 39c63e31a2..e79b828fc5 100644 --- a/config/examples/BQ/Hephestos/Configuration.h +++ b/config/examples/BQ/Hephestos/Configuration.h @@ -816,15 +816,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/BQ/Hephestos_2/Configuration.h b/config/examples/BQ/Hephestos_2/Configuration.h index ddf5ecf7c2..aa2dd95f2d 100644 --- a/config/examples/BQ/Hephestos_2/Configuration.h +++ b/config/examples/BQ/Hephestos_2/Configuration.h @@ -829,15 +829,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/BQ/WITBOX/Configuration.h b/config/examples/BQ/WITBOX/Configuration.h index bc4a058ff7..c1a5f95c58 100644 --- a/config/examples/BQ/WITBOX/Configuration.h +++ b/config/examples/BQ/WITBOX/Configuration.h @@ -816,15 +816,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Cartesio/Configuration.h b/config/examples/Cartesio/Configuration.h index 14c73f8256..4c4886e917 100644 --- a/config/examples/Cartesio/Configuration.h +++ b/config/examples/Cartesio/Configuration.h @@ -827,15 +827,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/CR-10/Configuration.h b/config/examples/Creality/CR-10/Configuration.h index b4b9a7b641..5a9c04c86c 100644 --- a/config/examples/Creality/CR-10/Configuration.h +++ b/config/examples/Creality/CR-10/Configuration.h @@ -838,15 +838,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/CR-10S/Configuration.h b/config/examples/Creality/CR-10S/Configuration.h index c1278b75fd..fe9b7a600e 100644 --- a/config/examples/Creality/CR-10S/Configuration.h +++ b/config/examples/Creality/CR-10S/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/CR-10_5S/Configuration.h b/config/examples/Creality/CR-10_5S/Configuration.h index d49fe6faf2..71c38600a8 100644 --- a/config/examples/Creality/CR-10_5S/Configuration.h +++ b/config/examples/Creality/CR-10_5S/Configuration.h @@ -829,15 +829,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/CR-10mini/Configuration.h b/config/examples/Creality/CR-10mini/Configuration.h index 394fbf63e1..4345f0767b 100644 --- a/config/examples/Creality/CR-10mini/Configuration.h +++ b/config/examples/Creality/CR-10mini/Configuration.h @@ -847,15 +847,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/CR-8/Configuration.h b/config/examples/Creality/CR-8/Configuration.h index fc1ab27827..c2891b70d0 100644 --- a/config/examples/Creality/CR-8/Configuration.h +++ b/config/examples/Creality/CR-8/Configuration.h @@ -838,15 +838,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/Ender-2/Configuration.h b/config/examples/Creality/Ender-2/Configuration.h index f355cf9885..02cdca926f 100644 --- a/config/examples/Creality/Ender-2/Configuration.h +++ b/config/examples/Creality/Ender-2/Configuration.h @@ -832,15 +832,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/Ender-3/Configuration.h b/config/examples/Creality/Ender-3/Configuration.h index bd4d338f1a..35efebeba5 100644 --- a/config/examples/Creality/Ender-3/Configuration.h +++ b/config/examples/Creality/Ender-3/Configuration.h @@ -832,15 +832,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Creality/Ender-4/Configuration.h b/config/examples/Creality/Ender-4/Configuration.h index 41d697067f..76c1657ac5 100644 --- a/config/examples/Creality/Ender-4/Configuration.h +++ b/config/examples/Creality/Ender-4/Configuration.h @@ -838,15 +838,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - #define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + #define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Einstart-S/Configuration.h b/config/examples/Einstart-S/Configuration.h index 4d4e161d79..6f915ed4e2 100644 --- a/config/examples/Einstart-S/Configuration.h +++ b/config/examples/Einstart-S/Configuration.h @@ -837,15 +837,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Felix/Configuration.h b/config/examples/Felix/Configuration.h index 0bd72dd751..758cf13c8c 100644 --- a/config/examples/Felix/Configuration.h +++ b/config/examples/Felix/Configuration.h @@ -810,15 +810,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Felix/DUAL/Configuration.h b/config/examples/Felix/DUAL/Configuration.h index 37548d7b14..6269947890 100644 --- a/config/examples/Felix/DUAL/Configuration.h +++ b/config/examples/Felix/DUAL/Configuration.h @@ -810,15 +810,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/FlashForge/CreatorPro/Configuration.h b/config/examples/FlashForge/CreatorPro/Configuration.h index ac1676a5f5..46a5c1b894 100644 --- a/config/examples/FlashForge/CreatorPro/Configuration.h +++ b/config/examples/FlashForge/CreatorPro/Configuration.h @@ -820,15 +820,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/FolgerTech/i3-2020/Configuration.h b/config/examples/FolgerTech/i3-2020/Configuration.h index 9ff1c44f97..b8fa6b5488 100644 --- a/config/examples/FolgerTech/i3-2020/Configuration.h +++ b/config/examples/FolgerTech/i3-2020/Configuration.h @@ -834,15 +834,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Formbot/Raptor/Configuration.h b/config/examples/Formbot/Raptor/Configuration.h index f2353bab21..6daf03396c 100644 --- a/config/examples/Formbot/Raptor/Configuration.h +++ b/config/examples/Formbot/Raptor/Configuration.h @@ -911,15 +911,71 @@ */ #define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Formbot/T_Rex_2+/Configuration.h b/config/examples/Formbot/T_Rex_2+/Configuration.h index f27e931b40..14826cb109 100644 --- a/config/examples/Formbot/T_Rex_2+/Configuration.h +++ b/config/examples/Formbot/T_Rex_2+/Configuration.h @@ -857,15 +857,71 @@ */ #define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) diff --git a/config/examples/Formbot/T_Rex_3/Configuration.h b/config/examples/Formbot/T_Rex_3/Configuration.h index c3fcb12013..e1ba05b0b8 100644 --- a/config/examples/Formbot/T_Rex_3/Configuration.h +++ b/config/examples/Formbot/T_Rex_3/Configuration.h @@ -844,15 +844,71 @@ */ #define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/A10M/Configuration.h b/config/examples/Geeetech/A10M/Configuration.h index bf073c5f50..f68b271b1d 100644 --- a/config/examples/Geeetech/A10M/Configuration.h +++ b/config/examples/Geeetech/A10M/Configuration.h @@ -811,16 +811,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - #define BLTOUCH_DELAY 200 // Minimum Command delay (ms). Enable and increase if needed - #define BLTOUCH_HS_MODE + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + #define BLTOUCH_DELAY 200 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + #define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/A20M/Configuration.h b/config/examples/Geeetech/A20M/Configuration.h index 2e0c0742b7..c3e6006cbd 100644 --- a/config/examples/Geeetech/A20M/Configuration.h +++ b/config/examples/Geeetech/A20M/Configuration.h @@ -811,16 +811,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - #define BLTOUCH_DELAY 200 // Minimum Command delay (ms). Enable and increase if needed - #define BLTOUCH_HS_MODE + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + #define BLTOUCH_DELAY 200 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + #define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/GT2560/Configuration.h b/config/examples/Geeetech/GT2560/Configuration.h index 81da7cf6d4..af98fe9fbc 100644 --- a/config/examples/Geeetech/GT2560/Configuration.h +++ b/config/examples/Geeetech/GT2560/Configuration.h @@ -843,15 +843,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/MeCreator2/Configuration.h b/config/examples/Geeetech/MeCreator2/Configuration.h index 902de41874..08f8234d90 100644 --- a/config/examples/Geeetech/MeCreator2/Configuration.h +++ b/config/examples/Geeetech/MeCreator2/Configuration.h @@ -835,15 +835,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h index c15e0177ef..c21dde26a6 100644 --- a/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro B/bltouch/Configuration.h @@ -848,15 +848,71 @@ */ #define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h index 7cbebd98ad..e31c8e1000 100644 --- a/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro B/noprobe/Configuration.h @@ -848,15 +848,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h index 774317e696..ea0ad8fb50 100644 --- a/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro C/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h b/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h index 332d1192a2..ecf6ac8f97 100644 --- a/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h +++ b/config/examples/Geeetech/Prusa i3 Pro W/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Infitary/i3-M508/Configuration.h b/config/examples/Infitary/i3-M508/Configuration.h index d3a2f313c2..82d11add64 100644 --- a/config/examples/Infitary/i3-M508/Configuration.h +++ b/config/examples/Infitary/i3-M508/Configuration.h @@ -832,15 +832,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/JGAurora/A5/Configuration.h b/config/examples/JGAurora/A5/Configuration.h index 3c941a05a6..cfb573eb85 100644 --- a/config/examples/JGAurora/A5/Configuration.h +++ b/config/examples/JGAurora/A5/Configuration.h @@ -840,15 +840,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/MakerParts/Configuration.h b/config/examples/MakerParts/Configuration.h index 36128f98be..4169aa3740 100644 --- a/config/examples/MakerParts/Configuration.h +++ b/config/examples/MakerParts/Configuration.h @@ -848,15 +848,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Malyan/M150/Configuration.h b/config/examples/Malyan/M150/Configuration.h index 296f474395..a723d9c012 100644 --- a/config/examples/Malyan/M150/Configuration.h +++ b/config/examples/Malyan/M150/Configuration.h @@ -848,15 +848,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Malyan/M200/Configuration.h b/config/examples/Malyan/M200/Configuration.h index cfa8463b06..3921bd4c89 100644 --- a/config/examples/Malyan/M200/Configuration.h +++ b/config/examples/Malyan/M200/Configuration.h @@ -827,15 +827,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Micromake/C1/basic/Configuration.h b/config/examples/Micromake/C1/basic/Configuration.h index d865baadff..764c83c845 100644 --- a/config/examples/Micromake/C1/basic/Configuration.h +++ b/config/examples/Micromake/C1/basic/Configuration.h @@ -832,15 +832,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Micromake/C1/enhanced/Configuration.h b/config/examples/Micromake/C1/enhanced/Configuration.h index 00bccf003d..9f44b63d40 100644 --- a/config/examples/Micromake/C1/enhanced/Configuration.h +++ b/config/examples/Micromake/C1/enhanced/Configuration.h @@ -832,15 +832,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Mks/Robin/Configuration.h b/config/examples/Mks/Robin/Configuration.h index c145a1c001..a295f48412 100644 --- a/config/examples/Mks/Robin/Configuration.h +++ b/config/examples/Mks/Robin/Configuration.h @@ -829,15 +829,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Mks/Sbase/Configuration.h b/config/examples/Mks/Sbase/Configuration.h index 0cac8f55f5..59be6ede75 100644 --- a/config/examples/Mks/Sbase/Configuration.h +++ b/config/examples/Mks/Sbase/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Printrbot/PrintrboardG2/Configuration.h b/config/examples/Printrbot/PrintrboardG2/Configuration.h index 9aa4fdbecc..65714d0c77 100644 --- a/config/examples/Printrbot/PrintrboardG2/Configuration.h +++ b/config/examples/Printrbot/PrintrboardG2/Configuration.h @@ -836,15 +836,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/RapideLite/RL200/Configuration.h b/config/examples/RapideLite/RL200/Configuration.h index 2171159e5a..5718ec16d0 100644 --- a/config/examples/RapideLite/RL200/Configuration.h +++ b/config/examples/RapideLite/RL200/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/RepRapPro/Huxley/Configuration.h b/config/examples/RepRapPro/Huxley/Configuration.h index 125b282705..7ae2ce5a61 100644 --- a/config/examples/RepRapPro/Huxley/Configuration.h +++ b/config/examples/RepRapPro/Huxley/Configuration.h @@ -868,15 +868,71 @@ Black rubber belt(MXL), 18 - tooth aluminium pulley : 87.489 step per mm (Huxley */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/RepRapWorld/Megatronics/Configuration.h b/config/examples/RepRapWorld/Megatronics/Configuration.h index 260d1bb488..df65f1acff 100644 --- a/config/examples/RepRapWorld/Megatronics/Configuration.h +++ b/config/examples/RepRapWorld/Megatronics/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/RigidBot/Configuration.h b/config/examples/RigidBot/Configuration.h index 3aaadc444a..ea7f255bbe 100644 --- a/config/examples/RigidBot/Configuration.h +++ b/config/examples/RigidBot/Configuration.h @@ -826,15 +826,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/SCARA/Configuration.h b/config/examples/SCARA/Configuration.h index ce5279805d..46c998ebac 100644 --- a/config/examples/SCARA/Configuration.h +++ b/config/examples/SCARA/Configuration.h @@ -841,15 +841,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/STM32/Black_STM32F407VET6/Configuration.h b/config/examples/STM32/Black_STM32F407VET6/Configuration.h index 70e457b59a..e6698a6225 100644 --- a/config/examples/STM32/Black_STM32F407VET6/Configuration.h +++ b/config/examples/STM32/Black_STM32F407VET6/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/STM32/STM32F10/Configuration.h b/config/examples/STM32/STM32F10/Configuration.h index 9fbd2cd4cf..ed98a9dad8 100644 --- a/config/examples/STM32/STM32F10/Configuration.h +++ b/config/examples/STM32/STM32F10/Configuration.h @@ -830,15 +830,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/STM32/STM32F4/Configuration.h b/config/examples/STM32/STM32F4/Configuration.h index 137ad945a5..07f140c19b 100644 --- a/config/examples/STM32/STM32F4/Configuration.h +++ b/config/examples/STM32/STM32F4/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/STM32/stm32f103ret6/Configuration.h b/config/examples/STM32/stm32f103ret6/Configuration.h index 1d8ee2d0d6..be99c96901 100644 --- a/config/examples/STM32/stm32f103ret6/Configuration.h +++ b/config/examples/STM32/stm32f103ret6/Configuration.h @@ -830,15 +830,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Sanguinololu/Configuration.h b/config/examples/Sanguinololu/Configuration.h index 412fe24e77..464d58bc0c 100644 --- a/config/examples/Sanguinololu/Configuration.h +++ b/config/examples/Sanguinololu/Configuration.h @@ -859,15 +859,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/TheBorg/Configuration.h b/config/examples/TheBorg/Configuration.h index d3aedbfe77..d9b2d41af1 100644 --- a/config/examples/TheBorg/Configuration.h +++ b/config/examples/TheBorg/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/TinyBoy2/Configuration.h b/config/examples/TinyBoy2/Configuration.h index fc96df55ec..18cd42da3f 100644 --- a/config/examples/TinyBoy2/Configuration.h +++ b/config/examples/TinyBoy2/Configuration.h @@ -879,15 +879,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Tronxy/X1/Configuration.h b/config/examples/Tronxy/X1/Configuration.h index 5be329d417..762500386b 100644 --- a/config/examples/Tronxy/X1/Configuration.h +++ b/config/examples/Tronxy/X1/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Tronxy/X3A/Configuration.h b/config/examples/Tronxy/X3A/Configuration.h index 0f51e5d183..bb4ec62546 100644 --- a/config/examples/Tronxy/X3A/Configuration.h +++ b/config/examples/Tronxy/X3A/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Tronxy/X5S-2E/Configuration.h b/config/examples/Tronxy/X5S-2E/Configuration.h index a9fb0d0cdf..d74013daeb 100644 --- a/config/examples/Tronxy/X5S-2E/Configuration.h +++ b/config/examples/Tronxy/X5S-2E/Configuration.h @@ -849,15 +849,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Tronxy/X5S/Configuration.h b/config/examples/Tronxy/X5S/Configuration.h index 9426ee3c4d..c6ba3ca2bf 100644 --- a/config/examples/Tronxy/X5S/Configuration.h +++ b/config/examples/Tronxy/X5S/Configuration.h @@ -827,15 +827,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Tronxy/XY100/Configuration.h b/config/examples/Tronxy/XY100/Configuration.h index 6a117c53cd..025ec00f59 100644 --- a/config/examples/Tronxy/XY100/Configuration.h +++ b/config/examples/Tronxy/XY100/Configuration.h @@ -839,15 +839,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/UltiMachine/Archim1/Configuration.h b/config/examples/UltiMachine/Archim1/Configuration.h index e7342881ba..e4beb53ea5 100644 --- a/config/examples/UltiMachine/Archim1/Configuration.h +++ b/config/examples/UltiMachine/Archim1/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/UltiMachine/Archim2/Configuration.h b/config/examples/UltiMachine/Archim2/Configuration.h index ddee01d5aa..c4763f256a 100644 --- a/config/examples/UltiMachine/Archim2/Configuration.h +++ b/config/examples/UltiMachine/Archim2/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/VORONDesign/Configuration.h b/config/examples/VORONDesign/Configuration.h index d5220e484c..d97c0ffe7c 100644 --- a/config/examples/VORONDesign/Configuration.h +++ b/config/examples/VORONDesign/Configuration.h @@ -837,15 +837,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Velleman/K8200/Configuration.h b/config/examples/Velleman/K8200/Configuration.h index f24830b612..ae1de59384 100644 --- a/config/examples/Velleman/K8200/Configuration.h +++ b/config/examples/Velleman/K8200/Configuration.h @@ -857,15 +857,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Velleman/K8400/Configuration.h b/config/examples/Velleman/K8400/Configuration.h index ef2e0da4dd..3c2a633d64 100644 --- a/config/examples/Velleman/K8400/Configuration.h +++ b/config/examples/Velleman/K8400/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Velleman/K8400/Dual-head/Configuration.h b/config/examples/Velleman/K8400/Dual-head/Configuration.h index 7b12f3db4c..cc9d04a912 100644 --- a/config/examples/Velleman/K8400/Dual-head/Configuration.h +++ b/config/examples/Velleman/K8400/Dual-head/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/WASP/PowerWASP/Configuration.h b/config/examples/WASP/PowerWASP/Configuration.h index 3f3b5a68b6..a0f6d3782e 100644 --- a/config/examples/WASP/PowerWASP/Configuration.h +++ b/config/examples/WASP/PowerWASP/Configuration.h @@ -847,15 +847,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/Wanhao/Duplicator 6/Configuration.h b/config/examples/Wanhao/Duplicator 6/Configuration.h index 782e554151..1c94e69744 100644 --- a/config/examples/Wanhao/Duplicator 6/Configuration.h +++ b/config/examples/Wanhao/Duplicator 6/Configuration.h @@ -838,15 +838,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/adafruit/ST7565/Configuration.h b/config/examples/adafruit/ST7565/Configuration.h index 52f079b8ff..713e7c4f8e 100644 --- a/config/examples/adafruit/ST7565/Configuration.h +++ b/config/examples/adafruit/ST7565/Configuration.h @@ -828,15 +828,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/Anycubic/Kossel/Configuration.h b/config/examples/delta/Anycubic/Kossel/Configuration.h index 10b589bb0e..c1c4d553a4 100644 --- a/config/examples/delta/Anycubic/Kossel/Configuration.h +++ b/config/examples/delta/Anycubic/Kossel/Configuration.h @@ -964,15 +964,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/FLSUN/auto_calibrate/Configuration.h b/config/examples/delta/FLSUN/auto_calibrate/Configuration.h index 864221773b..f2e52f2529 100644 --- a/config/examples/delta/FLSUN/auto_calibrate/Configuration.h +++ b/config/examples/delta/FLSUN/auto_calibrate/Configuration.h @@ -910,15 +910,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/FLSUN/kossel/Configuration.h b/config/examples/delta/FLSUN/kossel/Configuration.h index 19c001d44e..5e1abe90c5 100644 --- a/config/examples/delta/FLSUN/kossel/Configuration.h +++ b/config/examples/delta/FLSUN/kossel/Configuration.h @@ -910,15 +910,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/FLSUN/kossel_mini/Configuration.h b/config/examples/delta/FLSUN/kossel_mini/Configuration.h index cee35393b2..b956be5a9f 100644 --- a/config/examples/delta/FLSUN/kossel_mini/Configuration.h +++ b/config/examples/delta/FLSUN/kossel_mini/Configuration.h @@ -910,15 +910,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/Geeetech/Rostock 301/Configuration.h b/config/examples/delta/Geeetech/Rostock 301/Configuration.h index 95f0a63767..703b9ffac1 100644 --- a/config/examples/delta/Geeetech/Rostock 301/Configuration.h +++ b/config/examples/delta/Geeetech/Rostock 301/Configuration.h @@ -900,15 +900,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/Hatchbox_Alpha/Configuration.h b/config/examples/delta/Hatchbox_Alpha/Configuration.h index 331c10bd7f..1c7983f247 100644 --- a/config/examples/delta/Hatchbox_Alpha/Configuration.h +++ b/config/examples/delta/Hatchbox_Alpha/Configuration.h @@ -915,15 +915,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/MKS/SBASE/Configuration.h b/config/examples/delta/MKS/SBASE/Configuration.h index 60cde51bc6..6706774305 100644 --- a/config/examples/delta/MKS/SBASE/Configuration.h +++ b/config/examples/delta/MKS/SBASE/Configuration.h @@ -900,15 +900,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/generic/Configuration.h b/config/examples/delta/generic/Configuration.h index 314e24dd3f..b53651826f 100644 --- a/config/examples/delta/generic/Configuration.h +++ b/config/examples/delta/generic/Configuration.h @@ -900,15 +900,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/kossel_mini/Configuration.h b/config/examples/delta/kossel_mini/Configuration.h index 97e37d35c6..aeb4db9018 100644 --- a/config/examples/delta/kossel_mini/Configuration.h +++ b/config/examples/delta/kossel_mini/Configuration.h @@ -900,15 +900,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/kossel_pro/Configuration.h b/config/examples/delta/kossel_pro/Configuration.h index e8c043868e..66f418461b 100644 --- a/config/examples/delta/kossel_pro/Configuration.h +++ b/config/examples/delta/kossel_pro/Configuration.h @@ -893,15 +893,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/delta/kossel_xl/Configuration.h b/config/examples/delta/kossel_xl/Configuration.h index 05c4632e28..093b39a3d3 100644 --- a/config/examples/delta/kossel_xl/Configuration.h +++ b/config/examples/delta/kossel_xl/Configuration.h @@ -903,15 +903,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/makibox/Configuration.h b/config/examples/makibox/Configuration.h index 0635382de6..3b6df81fd7 100644 --- a/config/examples/makibox/Configuration.h +++ b/config/examples/makibox/Configuration.h @@ -831,15 +831,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/tvrrug/Round2/Configuration.h b/config/examples/tvrrug/Round2/Configuration.h index 6324822489..d29e148da0 100644 --- a/config/examples/tvrrug/Round2/Configuration.h +++ b/config/examples/tvrrug/Round2/Configuration.h @@ -823,15 +823,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE diff --git a/config/examples/wt150/Configuration.h b/config/examples/wt150/Configuration.h index c88cc543c5..9cc7ba85de 100644 --- a/config/examples/wt150/Configuration.h +++ b/config/examples/wt150/Configuration.h @@ -833,15 +833,71 @@ */ //#define BLTOUCH #if ENABLED(BLTOUCH) - //#define BLTOUCH_DELAY 500 // Minimum Command delay (ms). Enable and increase if needed + /** + * Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES + * Do not activate settings that the probe might not understand. Clones might misunderstand + * advanced commands. + * + * Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then + * check the wiring of the BROWN, RED and ORANGE wires. + * + * Note: If the trigger signal of your probe is not being recognized, it has been very often + * because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable" + * like they would be with a real switch. So please check the wiring first. + * + * Settings for all BLTouch and clone probes: + */ + + // Safety: The probe needs time to recognize the command. + // Minimum command delay (ms). Enable and increase if needed. + //#define BLTOUCH_DELAY 500 /** - * BLTouch V3.0 and newer smart series - * For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV. - * If the pin trigger is not detected, first try swapping the black and white wires then toggle this. + * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: */ - //#define BLTOUCH_FORCE_5V_MODE -#endif + + // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful + // in special cases, like noisy or filtered input configurations. + //#define BLTOUCH_FORCE_SW_MODE + + /** + * Settings for BLTouch Smart 3.0 and 3.1 + * Summary: + * - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes + * - High-Speed mode + * - Disable LCD voltage options + */ + + /** + * Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller! + * V3.0 or 3.1: Set default mode to 5V mode at Marlin startup. + * If disabled, OD mode is the hard-coded default on 3.0 + * On startup, Marlin will compare its eeprom to this vale. If the selected mode + * differs, a mode set eeprom write will be completed at initialization. + * Use the option below to force an eeprom write to a V3.1 probe regardless. + */ + //#define BLTOUCH_SET_5V_MODE + + /** + * Safety: Activate if connecting a probe with an unknown voltage mode. + * V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0 + * V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write ) + * To preserve the life of the probe, use this once then turn it off and re-flash. + */ + //#define BLTOUCH_FORCE_MODE_SET + + /** + * Use "HIGH SPEED" mode for probing. + * Danger: Disable if your probe sometimes fails. Only suitable for stable well-adjusted systems. + * This feature was designed for Delta's with very fast Z moves however higher speed cartesians may function + * If the machine cannot raise the probe fast enough after a trigger, it may enter a fault state. + */ + //#define BLTOUCH_HS_MODE + + // Safety: Enable voltage mode settings in the LCD menu. + //#define BLTOUCH_LCD_VOLTAGE_MENU + +#endif // BLTOUCH // A probe that is deployed and stowed with a solenoid pin (SOL1_PIN) //#define SOLENOID_PROBE