Browse Source

Corrected the ABL grid option

G29 E was not retracting the probe on the last probe point when used with ABL grid. Corrected.
pull/1/head
msutas 10 years ago
parent
commit
3a5a6f42fb
  1. 2
      Marlin/Marlin_main.cpp

2
Marlin/Marlin_main.cpp

@ -1759,7 +1759,7 @@ void process_commands()
if ((yProbe==FRONT_PROBE_BED_POSITION) && (xCount==0))
{
measured_z = probe_pt(xProbe, yProbe, z_before,1);
} else if ((yProbe==BACK_PROBE_BED_POSITION) && (xCount == AUTO_BED_LEVELING_GRID_POINTS-1))
} else if ((yProbe==FRONT_PROBE_BED_POSITION + (yGridSpacing * (AUTO_BED_LEVELING_GRID_POINTS-1))) && (xCount == AUTO_BED_LEVELING_GRID_POINTS-1))
{
measured_z = probe_pt(xProbe, yProbe, z_before,3);
} else {

Loading…
Cancel
Save